1.
Br Dent J ; 231(11): 701, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34893731
2.
Br Dent J ; 231(8): 481-485, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34686815

RESUMO

Introduction Reversal of enamel-only proximal caries by non-invasive treatments is important in preventive dentistry. However, detecting such caries using bitewing radiography is difficult and the subtle patterns are often missed by dental practitioners.Aims To investigate whether the ability of dentists to detect enamel-only proximal caries is enhanced by the use of AssistDent artificial intelligence (AI) software.Materials and methods In the ADEPT (AssistDent Enamel-only Proximal caries assessmenT) study, 23 dentists were randomly divided into a control arm, without AI assistance, and an experimental arm, in which AI assistance provided on-screen prompts indicating potential enamel-only proximal caries. All participants analysed a set of 24 bitewings in which an expert panel had previously identified 65 enamel-only carious lesions and 241 healthy proximal surfaces.Results The control group found 44.3% of the caries, whereas the experimental group found 75.8%. The experimental group incorrectly identified caries in 14.6% of the healthy surfaces compared to 3.7% in the control group. The increase in sensitivity of 71% and decrease in specificity of 11% are statistically significant (p <0.01).Conclusions AssistDent AI software significantly improves dentists' ability to detect enamel-only proximal caries and could be considered as a tool to support preventive dentistry in general practice.


Assuntos
Suscetibilidade à Cárie Dentária , Cárie Dentária , Inteligência Artificial , Cárie Dentária/diagnóstico por imagem , Esmalte Dentário/diagnóstico por imagem , Dentina , Odontólogos , Humanos , Papel Profissional , Radiografia Interproximal , Distribuição Aleatória , Software
3.
Skeletal Radiol ; 42(4): 511-20, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23053200

RESUMO

OBJECTIVE: The transverse relaxation time (T2) in MR imaging has been identified as a potential biomarker of hyaline cartilage pathology. This study investigates whether MR assessments of T2 are comparable between 3-T scanners from three different vendors. DESIGN: Twelve subjects with symptoms of knee osteoarthritis and one or more risk factors had their knee scanned on each of the three vendors' scanners located in three sites in the U.K. MR data acquisition was based on the United States National Institutes of Health Osteoarthritis Initiative protocol. Measures of cartilage T2 and R2 (inverse of T2) were computed for precision error assessment. Intrascanner reproducibility was also assessed with a phantom (all three scanners) and a cohort of 5 subjects (one scanner only). RESULTS: Whole-organ magnetic resonance (WORM) semiquantitative cartilage scores ranged from minimal to advanced degradation. Intrascanner R2 root-mean-square coefficients of variation (RMSCOV) were low, within the range 2.6 to 6.3% for femoral and tibial regions. For one scanner pair, mean T2 differences ranged from -1.2 to 2.8 ms, with no significant difference observed for the medial tibia and patella regions (p < 0.05). T2 values from the third scanner were systematically lower, producing interscanner mean T2 differences within the range 5.4 to 10.0 ms. CONCLUSION: Significant interscanner cartilage T2 differences were found and should be accounted for before data from scanners of different vendors are compared.


Assuntos
Cartilagem/patologia , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Osteoartrite do Joelho/patologia , Adulto , Estudos Transversais , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Reino Unido
4.
Arthritis Res Ther ; 12(5): R202, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21029439

RESUMO

INTRODUCTION: Cartilage thickness from MR images has been identified as a possible biomarker in knee osteoarthritis (OA) research. The ability to acquire MR data at multiple centers by using different vendors' scanners would facilitate patient recruitment and shorten the duration of OA trials. Several vendors manufacture 3T MR scanners, including Siemens, Philips Medical Systems, and GE Healthcare. This study investigates whether quantitative MR assessments of cartilage morphology are comparable between scanners of three different vendors. METHODS: Twelve subjects with symptoms of knee OA and one or more risk factors had their symptomatic knee scanned on each of the three vendor's scanners located in three sites in the UK: Manchester (Philips), York (GE), and Liverpool (Siemens). The NIH OAI study protocol was used for the Siemens scanner, and equivalent protocols were developed for the Philips and GE scanners with vendors' advice. Cartilage was segmented manually from sagittal 3D images. By using recently described techniques for Anatomically Corresponded Regional Analysis of Cartilage (ACRAC), a statistical model was used anatomically to align all the images and to produce detailed maps of mean differences in cartilage-thickness measures between scanners. Measures of cartilage mean thickness were computed in anatomically equivalent regions for each subject and scanner image. RESULTS: The ranges of mean cartilage-thickness measures for this cohort were similar for all regions and across all scanners. Philips intrascanner root-mean-square coefficients of variation were low in the range from 2.6% to 4.6%. No significant differences were found for thickness measures of the weight-bearing femorotibial regions from the Philips and Siemens images except for the central medial femur compartment (P = 0.04). Compared with the other two scanners, the GE scanner provided consistently lower mean thickness measures in the central femoral regions (mean difference, -0.16 mm) and higher measures in the tibial compartments (mean difference, +0.19 mm). CONCLUSIONS: The OAI knee-imaging protocol, developed on the Siemens platform, can be applied to research and trials by using other vendors' 3T scanners giving comparable morphologic results. Accurate sequence optimization, differences in image postprocessing, and extremity coil type are critical factors for interscanner precision of quantitative analysis of cartilage morphology. It is still recommended that longitudinal observations on individuals should be performed on the same scanner and that assessment of intra- and interscanner precision errors is undertaken before commencement of the main study.


Assuntos
Cartilagem Articular/patologia , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Osteoartrite do Joelho/patologia , Humanos , Interpretação de Imagem Assistida por Computador , Articulação do Joelho/patologia , Reprodutibilidade dos Testes
5.
IEEE Trans Med Imaging ; 29(8): 1541-59, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20378463

RESUMO

Magnetic resonance imaging (MRI) is emerging as the method of choice for measuring cartilage loss in osteoarthritis (OA), but current methods of analysis are imperfect for therapeutic clinical trials. In this paper, we present and evaluate, in two multicenter multivendor studies, a new method for anatomically corresponded regional analysis of cartilage (ACRAC) that allows analysis of knee cartilage morphology in anatomically corresponding focal regions defined on the bone surface. In our first study, 3-D knee MR Images were obtained from 19 asymptomatic female volunteers, followed by segmentations of the bone and cartilage. Minimum description length (MDL) statistical shape models (SSMs) were constructed from the segmented bone surfaces, providing mean bone shapes and a dense set of anatomically corresponding positions on each individual bone, the accuracy of which were measured using repeat images from a subset of the volunteers. Cartilage thicknesses were measured at these locations along 3-D normals to the bone surfaces, yielding corresponded cartilage thickness maps. Functional subregions of the joint were defined on the mean bone shapes, and propagated, using the correspondences, to each individual. ACRAC improved reproducibility, particularly in the central, load bearing subregions of the joint, compared with measures of volume obtained directly from the segmented cartilage surfaces. In our second study, MR Images were obtained from 31 female patient-volunteers with knee OA at baseline and six months. We obtained manual segmentations of the cartilage, and automatic segmentations of the bone using active appearance models (AAMs) built from the bone SSMs of the first study. ACRAC enabled the detection of significant thickness loss in the central, load-bearing regions of the whole femur (-5.57% p = 0.01, annualized) and the medial condyle (-13.08% , p = 0.024 Bonferroni corrected, annualized). We conclude that statistical shape modelling of bone surfaces defines correspondences invariant to individual joint size or shape, providing focal measures of cartilage with improved reproducibility compared to whole compartment measures. It permits the identification of anatomically equivalent regions, and provides the ability to identify the main load-bearing regions of the joint, based on the imputed premorbid state. The method permitted detection of tiny morphological change in cartilage thickness over six months in a small study, and may be useful for OA disease analysis and treatment monitoring.


Assuntos
Cartilagem Hialina/anatomia & histologia , Imageamento Tridimensional/métodos , Joelho/anatomia & histologia , Ossos da Perna/anatomia & histologia , Modelos Anatômicos , Modelos Estatísticos , Osteoartrite do Joelho/fisiopatologia , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
6.
J Pathol ; 219(1): 61-8, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19479712

RESUMO

Although deregulated Hedgehog signalling and elevated Gli transcription factor expression are known to promote the development of basal cell carcinoma (BCC), little is known about molecular mechanisms driving the development of specific growth pattern subtypes. Using gene array analysis, we have previously observed that over-expression of GLI1 in human keratinocytes promotes increased expression of the neuronal differentiation markers ARC and ULK1. We asked whether neuronal differentiation is a characteristic of BCC and whether there is any correlation with BCC subtype. Using RT-PCR and immunohistochemistry, we confirmed that the neuronal markers ARC, beta-tubulin III, GAP-43 and Neurofilament are expressed in human BCC but not in normal epidermis. Moreover, we found that expression of these neuronal differentiation markers showed strong correlation to BCC subtype, with more aggressive infiltrative and morphoeic BCC showing low levels or lack of expression compared to nodular, superficial and micronodular subtypes. Primary human keratinocytes retrovirally expressing GLI1(-) and GLI2(-) showed elevated levels of beta-tubulin III and ARC but not Neurofilament or GAP-43, suggesting that beta-tubulin III and Arc may be early targets of aberrant Gli expression in BCC, whereas expression of Neurofilament and GAP-43 are either later, downstream targets or under control of alternative pathways. We propose that neuronal differentiation is a feature of BCC and that expression of these markers is in part due to aberrant Hedgehog signalling. Moreover, we suggest that correlation between loss of expression of neuronal markers in infiltrative and morphoeic BCC subtypes reflects dedifferentiation of more aggressive BCC subtypes.


Assuntos
Carcinoma Basocelular/patologia , Regulação Neoplásica da Expressão Gênica , Proteínas Hedgehog/genética , Neurônios/patologia , Análise de Variância , Biomarcadores/análise , Carcinoma Basocelular/genética , Carcinoma Basocelular/metabolismo , Estudos de Casos e Controles , Diferenciação Celular , Células Cultivadas , Proteínas do Citoesqueleto/genética , Proteína GAP-43/genética , Proteínas Hedgehog/metabolismo , Humanos , Interpretação de Imagem Assistida por Computador , Imuno-Histoquímica , Queratinócitos/metabolismo , Fatores de Transcrição Kruppel-Like/genética , Proteínas do Tecido Nervoso/genética , Proteínas de Neurofilamentos/genética , Plasticidade Neuronal , Proteínas Nucleares/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Transdução de Sinais/fisiologia , Fatores de Transcrição/genética , Transdução Genética , Tubulina (Proteína)/genética , Proteína GLI1 em Dedos de Zinco , Proteína Gli2 com Dedos de Zinco
7.
Carcinogenesis ; 29(4): 738-46, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18281251

RESUMO

Basal cell carcinoma (BCC) of the skin is a highly compact, non-metastatic epithelial tumour type that may arise from the aberrant propagation of epidermal or progenitor stem cell (SC) populations. Increased expression of GLI1 is a common feature of BCC and is linked to the induction of epidermal SC markers in immortalized N/Tert-1 keratinocytes. Here, we demonstrate that GLI1 over-expression is linked to additional SC characteristics in N/Tert-1 cells including reduced epidermal growth factor receptor (EGFR) expression and compact colony formation that is associated with repressed extracellular signal-regulated kinase (ERK) activity. Colony formation and repressed ERK activity remain evident when EGFR is increased exogenously to the basal levels in GLI1 cells revealing that ERK is additionally inhibited downstream of the receptor. Exposure to epidermal growth factor (EGF) to increase ERK activity and promote migration negates GLI1 colony formation with cells displaying an elongated, fibroblast-like morphology. However, as determined by Snail messenger RNA and E-cadherin protein expression this is not associated with epithelial-mesenchymal transition (EMT), and GLI1 actually represses induction of the EMT marker vimentin in EGF-stimulated cells. Instead, live cell imaging revealed that the elongated morphology of EGF/GLI1 keratinocytes stems from their being 'stretched' due to migrating cells displaying inefficient cell-cell detachment and impaired tail retraction. Taken together, these data suggest that GLI1 opposes EGFR signalling to maintain the epithelial phenotype. Finally, ERK activity was predominantly negative in 13/14 BCCs (superficial/nodular), indicating that GLI1 does not routinely co-operate with ERK to induce the formation of this common skin tumour.


Assuntos
Movimento Celular/fisiologia , MAP Quinases Reguladas por Sinal Extracelular/metabolismo , Queratinócitos/citologia , Queratinócitos/fisiologia , Fatores de Transcrição/metabolismo , Carcinoma Basocelular , Adesão Celular , Divisão Celular , Linhagem Celular Tumoral , Primers do DNA , Células Epidérmicas , Epiderme/fisiologia , Genes Reporter , Humanos , Reação em Cadeia da Polimerase , Neoplasias Cutâneas , Proteína GLI1 em Dedos de Zinco
8.
Inf Process Med Imaging ; 19: 566-77, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-17354726

RESUMO

Active Shape Models are a popular method for segmenting three-dimensional medical images. To obtain the required landmark correspondences, various automatic approaches have been proposed. In this work, we present an improved version of minimizing the description length (MDL) of the model. To initialize the algorithm, we describe a method to distribute landmarks on the training shapes using a conformal parameterization function. Next, we introduce a novel procedure to modify landmark positions locally without disturbing established correspondences. We employ a gradient descent optimization to minimize the MDL cost function, speeding up automatic model building by several orders of magnitude when compared to the original MDL approach. The necessary gradient information is estimated from a singular value decomposition, a more accurate technique to calculate the PCA than the commonly used eigendecomposition of the covariance matrix. Finally, we present results for several synthetic and real-world datasets demonstrating that our procedure generates models of significantly better quality in a fraction of the time needed by previous approaches.


Assuntos
Algoritmos , Inteligência Artificial , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Reconhecimento Automatizado de Padrão/métodos , Técnica de Subtração , Simulação por Computador , Humanos , Imageamento Tridimensional/métodos , Fígado/diagnóstico por imagem , Pulmão/anatomia & histologia , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Inf Process Med Imaging ; 18: 126-35, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15344452

RESUMO

We present a method for corresponding and combining cartilage thickness readings from a population of patients using the underlying bone structure as a reference. Knee joint femoral bone and cartilage surfaces are constructed from a set of parallel slice segmentations of MR scans. Correspondence points across a population of bone surfaces are defined and refined by minimising an objective function based on the Minimum Description Length of the resulting statistical shape model. The optimised bone model defines a set of corresponding locations from which 3D measurements of the cartilage thickness can be taken and combined for a population of patients. Results are presented for a small group of patients demonstrating the feasibility and potential of the approach as a means of detecting sub-millimetre cartilage thickness changes due to disease progression.


Assuntos
Algoritmos , Artrite/diagnóstico , Cartilagem Articular/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Articulação do Joelho/patologia , Reconhecimento Automatizado de Padrão , Simulação por Computador , Estudos de Viabilidade , Fêmur/patologia , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética , Modelos Biológicos , Modelos Estatísticos , Técnica de Subtração