Cancers (Basel) ; 15(17)2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37686597

RESUMO

(1) Background: Radiotherapy (RT) is a central component for the treatment of many head and neck cancers. In this systematic review of the literature, we aimed to characterize and quantify the published evidence on RT-related hypothyroidism, including estimated incidence, clinical risk factors, and dosimetric parameters that may be used to guide clinical decision making. Furthermore, we aimed to identify potential areas of improvement in the prevention and clinical management of RT-induced hypothyroidism, including the role of modern advanced therapeutic techniques. (2) Methods: We conducted a systemic review of the literature in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. PubMed and Google Scholar were searched to identify original research articles describing the incidence, mechanism, dosimetry, treatment, or prevention of radiation-related hypothyroidism for adults receiving RT for the treatment of head and neck cancers. The snowball method was used to identify additional articles. For identified articles, we tabulated several datapoints, including publication date, patient sample size, estimated hypothyroidism incidence, cancer site/type, follow-up period, radiation modality and technique, use of multimodality therapy, method of thyroid function evaluation, and proposed dosimetric predictors of hypothyroidism. (3) Results: One hundred and eleven articles met inclusion criteria, reflecting a range of head and neck cancer subtypes. There was a large variation in the estimated incidence of RT-related hypothyroidism, with a median estimate of 36% (range 3% to 79%). Reported incidence increased in later publication dates, which was likely related to improved screening and longer follow up. There were a wide variety of predictive metrics used to identify patients at high risk of hypothyroidism, the most common of which were volumetric and mean dosimetrics related to the thyroid gland (Vxx%, Dmean). More recently, there has been increasing evidence to suggest that the thyroid gland volume itself and the volume of the thyroid gland spared from high-dose radiation (VSxx) may better predict thyroid function after RT. There were no identified studies investigating the role of advanced radiotherapeutic techniques such as MRI-guided RT or particle therapy to decrease RT-related hypothyroidism. Conclusions: Hypothyroidism is a common toxicity resulting from therapeutic radiation for head and neck cancer with recent estimates suggesting 40-50% of patients may experience hypothyroidism after treatment. Dosimetric predictive models are increasingly able to accurately identify patients at risk of hypothyroidism, especially those utilizing thyroid VS metrics. Further investigation regarding the potential for advanced radiotherapeutic therapies to decrease RT-induced thyroid dysfunction is needed.

2.
Radiat Oncol ; 17(1): 4, 2022 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-34991637

RESUMO

BACKGROUND: Re-irradiation (re-RT) is a technically challenging task for which few standardized approaches exist. This is in part due to the lack of a common platform to assess dose tolerance in relation to toxicity in the re-RT setting. To better address this knowledge gap and provide new tools for studying and developing thresholds for re-RT, we developed a novel algorithm that allows for anatomically accurate three-dimensional mapping of composite biological effective dose (BED) distributions from nominal doses (Gy). METHODS: The algorithm was designed to automatically convert nominal dose from prior treatment plans to corresponding BED value maps (voxel size 2.5 mm3 and α/ß of 3 for normal tissue, BED3). Following the conversion of each plan to a BED3 dose distribution, deformable registration was used to create a summed composite re-irradiation BED3 plan for each patient who received two treatments. A proof-of-principle analysis was performed on 38 re-irradiation cases of initial stereotactic ablative radiotherapy (SABR) followed by either re-SABR or chemoradiation for isolated locoregional recurrence of early-stage non-small cell lung cancer. RESULTS: Evaluation of the algorithm-generated maps revealed appropriate conversion of physical dose to BED at each voxel. Of 14 patients receiving repeat SABR, there was one case each of grade 3 chest wall pain (7%), pneumonitis (7%), and dyspnea (7%). Of 24 patients undergoing repeat fractionated radiotherapy, grade 3 events were limited to two cases each of pneumonitis and dyspnea (8%). Composite BED3 dosimetry for each patient who experienced grade 2-3 events is provided and may help guide development of precise cumulative dose thresholds for organs at risk in the re-RT setting. CONCLUSIONS: This novel algorithm successfully created a voxel-by-voxel composite treatment plan using BED values. This approach may be used to more precisely examine dosimetric predictors of toxicities and to establish more accurate normal tissue constraints for re-irradiation.


Assuntos
Algoritmos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Reirradiação/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos
3.
Int J Radiat Oncol Biol Phys ; 109(2): 441-448, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32946965

RESUMO

PURPOSE: To perform a planned interim analysis of acute (within 12 months) and late (after 12 months) toxicities and cosmetic outcomes after proton accelerated partial breast irradiation (APBI). METHODS AND MATERIALS: A total of 100 patients with pTis or pT1-2 N0 (≤3cm) breast cancer status after segmental mastectomy were enrolled in a single-arm phase 2 study from 2010 to 2019. The clinically determined postlumpectomy target volume, including tumor bed surgical clips and operative-cavity soft-tissue changes seen on imaging plus a radial clinical expansion, was irradiated with passively scattered proton APBI (34 Gy in 10 fractions delivered twice daily with a minimum 6-hour interfraction interval). Patients were evaluated at protocol-specific time intervals for recurrence, physician reports of cosmetic outcomes and toxicities, and patient reports of cosmetic outcomes and satisfaction with the treatment or experience. RESULTS: Median follow-up was 24 months (interquartile range [IQR], 12-43 months). Local control and overall survival were 100% at 12 and 24 months. There were no acute or late toxicities of grade 3 or higher; no patients experienced fat necrosis, fibrosis, infection, or breast shrinkage. Excellent or good cosmesis at 12 months was reported by 91% of patients and 94% of physicians; at the most recent follow-up, these were 94% and 87%, respectively. The most commonly reported late cosmetic effect was telangiectasis (17%). The total patient satisfaction rate for treatment and results at 12 and 24 months was 96% and 100%, respectively. Patients' mean time away from work was 5 days (IQR, 2-5 days), and the median out-of-pocket cost was $700 (IQR, $100-$1600). The mean left-sided heart dose was 2 cGy (range, 0.2-75 cGy), and the mean ipsilateral lung dose was 19 cGy (range, 0.2-164 cGy). CONCLUSIONS: Proton APBI is a maturing treatment option with high local control, favorable intermediate-term cosmesis, high treatment satisfaction, low treatment burden, and exceptional heart and lung sparing.


Assuntos
Neoplasias da Mama/radioterapia , Terapia com Prótons , Idoso , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Feminino , Seguimentos , Humanos , Mastectomia , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Resultado do Tratamento
4.
Adv Radiat Oncol ; 5(6): 1359-1363, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33305099

RESUMO

INTRODUCTION: Tongue-deviating oral stents (TDOS) are commonly used during unilateral neck radiation therapy to reduce unnecessary dose to nontarget oral structures. Their benefit in the setting of highly conformal treatment techniques, however, is not defined. The goal of this study was to investigate the potential benefit of TDOS use on dosimetric parameters in unilateral intensity modulated radiation therapy (IMRT) and intensity modulated proton therapy (IMPT). METHODS: A total of 16 patients with T1-2 tonsil cancer treated at a single institution were selected, of which 8 were simulated/treated with a TDOS and 8 without a TDOS. All received definitive unilateral IMRT to a dose of 66 Gy in 30 fx. IMPT plans were generated for each patient for study purposes and optimized according to standard institutional practice. RESULTS: For IMRT plans, the presence of a TDOS (vs without) was associated with a significantly lower oral mucosa mean dose (31.4 vs 35.3 Gy; P = .020) and V30 (42.7% vs 57.1%; P = .025). For IMPT plans, the presence of TDOS (vs without) was not associated with any improvement in oral mucosa mean dose (18.3 vs 19.9 Gy; P = .274) or V30 (25.0% vs 26.2%; P = .655). IMPT plans without TDOS compared with IMRT plans with TDOS demonstrated reduced oral mucosa mean dose (P < .001) and V30 (P < .001). CONCLUSION: The use of a TDOS for the unilateral treatment of well-lateralized tonsil cancers was associated with oral mucosa sparing for IMRT, but not for IMPT. Moreover, mucosa sparing was improved for IMPT plans without a TDOS compared to IMRT plans with a TDOS.

5.
Phys Imaging Radiat Oncol ; 13: 44-49, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32551371

RESUMO

BACKGROUND AND PURPOSE: Computed tomography (CT) scanning is the basis for radiation treatment planning, but the 50-cm standard scanning field of view (sFOV) may be too small for imaging larger patients. We evaluated the 65-cm high-definition (HD) FOV of a large-bore CT scanner for CT number accuracy, geometric distortion, image quality degradation, and dosimetric accuracy of photon treatment plans. MATERIALS AND METHODS: CT number accuracy was tested by placing two 16-cm acrylic phantoms on either side of a 40-cm phantom to simulate a large patient extending beyond the 50-cm-diameter standard scanning FOV. Dosimetric accuracy was tested using anthropomorphic pelvis and thorax phantoms, with additional acrylic body parts on either side of the phantoms. Two volumetric modulated arc therapy beams (a 15-MV and a 6-MV) were used to cover the planning target volumes. Two-dimensional dose distributions were evaluated with GAFChromic film and point dose accuracy was checked with multiple thermoluminescent dosimeter (TLD) capsules placed in the phantoms. Image quality was tested by placing an American College of Radiology accreditation phantom inside the 40-cm phantom. RESULTS: The HD FOV showed substantial changes in CT numbers, with differences of 314 HU-725 HU at different density levels. The volume of the body parts extending into the HD FOV was distorted. However, TLD-reported doses for all PTVs agreed within ± 3%. Dose agreement in organs at risk were within the passing criteria, and the gamma index pass rate was >97%. Image quality was degraded. CONCLUSIONS: The HD FOV option is adequate for RT simulation and met accreditation standards, although care should be taken during contouring because of reduced image quality.

6.
J Appl Clin Med Phys ; 21(1): 166-173, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31808307

RESUMO

BACKGROUND AND PURPOSE: Magnetic resonance imaging (MRI) has gained popularity in radiation therapy simulation because it provides superior soft tissue contrast, which facilitates more accurate target delineation compared with computed tomography (CT) and does not expose the patient to ionizing radiation. However, image registration errors in commercial software have not been widely reported. Here we evaluated the accuracy of deformable image registration (DIR) by using a physical phantom for MRI. METHODS AND MATERIALS: We used the "Wuphantom" for end-to-end testing of DIR accuracy for MRI. This acrylic phantom is filled with water and includes several fillable inserts to simulate various tissue shapes and properties. Deformations and changes in anatomic locations are simulated by changing the rotations of the phantom and inserts. We used Varian Velocity DIR software (v4.0) and CT (head and neck protocol) and MR (T1- and T2-weighted head protocol) images to test DIR accuracy between image modalities (MRI vs CT) and within the same image modality (MRI vs MRI) in 11 rotation deformation scenarios. Large inserts filled with Mobil DTE oil were used to simulate fatty tissue, and small inserts filled with agarose gel were used to simulate tissues slightly denser than water (e.g., prostate). Contours of all inserts were generated before DIR to provide a baseline for contour size and shape. DIR was done with the MR Correctable Deformable DIR method, and all deformed contours were compared with the original contours. The Dice similarity coefficient (DSC) and mean distance to agreement (MDA) were used to quantitatively validate DIR accuracy. We also used large and small regions of interest (ROIs) during between-modality DIR tests to simulate validation of DIR accuracy for organs at risk (OARs) and propagation of individual clinical target volume (CTV) contours. RESULTS: No significant differences in DIR accuracy were found for T1:T1 and T2:T2 comparisons (P > 0.05). DIR was less accurate for between-modality comparisons than for same-modality comparisons, and was less accurate for T1 vs CT than for T2 vs CT (P < 0.001). For between-modality comparisons, use of a small ROI improved DIR accuracy for both T1 and T2 images. CONCLUSION: The simple design of the Wuphantom allows seamless testing of DIR; here we validated the accuracy of MRI DIR in end-to-end testing. T2 images had superior DIR accuracy compared with T1 images. Use of small ROIs improves DIR accuracy for target contour propagation.


Assuntos
Algoritmos , Neoplasias de Cabeça e Pescoço/patologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Neoplasias da Próstata/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica
7.
J Appl Clin Med Phys ; 20(10): 92-100, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31541526

RESUMO

PURPOSE: Kilo-voltage cone-beam computed tomography (CBCT) is widely used for patient alignment, contour propagation, and adaptive treatment planning in radiation therapy. In this study, we evaluated the accuracy of deformable image registration (DIR) for CBCT under various imaging protocols with different noise and patient dose levels. METHODS: A physical phantom previously developed to facilitate end-to-end testing of the DIR accuracy was used with Varian Velocity v4.0 software to evaluate the performance of image registration from CT to CT, CBCT to CT, and CBCT to CBCT. The phantom is acrylic and includes several inserts that simulate different tissue shapes and properties. Deformations and anatomic changes were simulated by changing the rotations of both the phantom and the inserts. CT images (from a head and neck protocol) and CBCT images (from pelvis, head and "Image Gently" protocols) were obtained with different image noise and dose levels. Large inserts were filled with Mobil DTE oil to simulate soft tissue, and small inserts were filled with bone materials. All inserts were contoured before the DIR process to provide a ground truth contour size and shape for comparison. After the DIR process, all deformed contours were compared with the originals using Dice similarity coefficient (DSC) and mean distance to agreement (MDA). Both large and small volume of interests (VOIs) for DIR volume selection were tested by simulating a DIR process that included whole patient image volume and clinical target volumes (CTV) only (for CTVs propagation). RESULTS: For cross-modality DIR registration (CT to CBCT), the DSC were >0.8 and the MDA were <3 mm for CBCT pelvis, and CBCT head protocols. For CBCT to CBCT and CT to CT, the DIR accuracy was improved relative to the cross-modality tests. For smaller VOIs, the DSC were >0.8 and MDA <2 mm for all modalities. CONCLUSIONS: The accuracy of DIR depends on the quality of the CBCT image at different dose and noise levels.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
8.
Oral Oncol ; 88: 66-74, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30616799

RESUMO

Radiation therapy plays an integral role in the management of head and neck cancers (HNCs). While most HNC patients have historically been treated with photon-based radiation techniques such as intensity modulated radiation therapy (IMRT), there is a growing awareness of the potential clinical benefits of proton therapy over IMRT in the definitive, postoperative and reirradiation settings given the unique physical properties of protons. Intensity modulated proton therapy (IMPT), also known as "pencil beam proton therapy," is a sophisticated mode of proton therapy that is analogous to IMRT and an active area of investigation in cancer care. Multifield optimization IMPT allows for high quality plans that can target superficially located HNCs as well as large neck volumes while significantly reducing integral doses. Several dosimetric studies have demonstrated the superiority of IMPT over IMRT to improve dose sparing of nearby organs such as the larynx, salivary glands, and esophagus. Evidence of the clinical translation of these dosimetric advantages has been demonstrated with documented toxicity reductions (such as decreased feeding tube dependency) after IMPT for patients with HNCs. While there are relative challenges to IMPT planning that exist today such as particle range uncertainties and high sensitivity to anatomical changes, ongoing investigations in image-guidance techniques and robust optimization methods are promising. A systematic approach towards utilizing IMPT and additional prospective studies are necessary in order to more accurately estimate the clinical benefit of IMPT over IMRT and passive proton therapy on a case-by-case basis for patients with sub-site specific HNCs.


Assuntos
Neoplasias de Cabeça e Pescoço/mortalidade , Neoplasias de Cabeça e Pescoço/terapia , Terapia com Prótons/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Fótons/efeitos adversos , Fótons/uso terapêutico , Terapia com Prótons/efeitos adversos , Radiodermite/etiologia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Retratamento , Estomatite/etiologia , Taxa de Sobrevida , Resultado do Tratamento