Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-22256082

RESUMO

Detection of epileptiform activity is of interest for responsive stimulation and diagnostic or monitoring devices in epilepsy; some implantable systems use low-computational-complexity algorithms such as line length trending and half-wave detection. Broadband noise was added to recorded electrocorticographic signals in order to model the potential impact of factors such as electrode-tissue interface properties and distance from the epileptic focus on these detection tools. Simulation demonstrated that half-wave and line length tools can yield consistent results in the presence of moderate amounts of noise.


Assuntos
Algoritmos , Artefatos , Eletrodos Implantados , Epilepsia/diagnóstico , Simulação por Computador , Eletroencefalografia , Humanos
2.
Clin Neurophysiol ; 119(12): 2687-96, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18993113

RESUMO

OBJECTIVE: A novel algorithm for automated seizure onset detection is presented. The method allows for precise identification of electrographic seizure onset times within large databases of electrographic data. METHODS: The patient-specific algorithm extracts salient spectral and temporal features in five frequency bands within a sliding window of an electrographic recording. Feature windows are classified as containing or not containing a seizure onset via support vector machines. A clustering and regression analysis is utilized to accurately localize seizure onsets in time. User-adjustable parameters allow for tuning of detection sensitivity, false positive rate, and latency. The method was tested on intracranial electrographic data recorded from six patients with a total of 1792 recorded seizure onsets from 8246 total electrographic recordings. RESULTS: Testing of algorithm performance via cross-validation resulted in sensitivities between 80% and 98%, false positive rates from 0.002 to 0.046 per minute (0.12-2.8 per hour), and median detection time within 100ms of the electrographic onset for all patients. In five of the six patients, more than 90% of all detected onsets were less than 3s from the electrographic onset. CONCLUSIONS: The detection system was able to detect seizure onset times in a temporally unbiased fashion with low latency while maintaining reasonable sensitivities and false positive rates. The regression algorithm for temporal localization of onsets confers a considerable benefit in terms of detection latency. SIGNIFICANCE: With the use of our algorithm, large databases of electrographic data can be rapidly processed and seizure onset times accurately marked, facilitating research and analyses of peri-onset events that require precise seizure onset alignment.


Assuntos
Encéfalo/fisiopatologia , Eletroencefalografia/métodos , Processamento Eletrônico de Dados/métodos , Convulsões/diagnóstico , Adulto , Algoritmos , Mapeamento Encefálico , Feminino , Humanos , Masculino , Modelos Neurológicos , Análise de Regressão , Reprodutibilidade dos Testes , Convulsões/fisiopatologia , Sensibilidade e Especificidade , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA