1.
Sensors (Basel) ; 24(5)2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38475219

RESUMO

Particulate matter (PM) suspended in the air significantly impacts human health. Those of anthropogenic origin are particularly hazardous. Poland is one of the countries where the air quality during the heating season is the worst in Europe. Air quality in small towns and villages far from state monitoring stations is often much worse than in larger cities where they are located. Their residents inhale the air containing smoke produced mainly by coal-fired stoves. In the frame of this project, an air quality monitoring network was built. It comprises low-cost PMS7003 PM sensors and ESP8266 microcontrollers with integrated Wi-Fi communication modules. This article presents research results on the influence of the PM sensor location on their indications. It has been shown that the indications from sensors several dozen meters away from each other can differ by up to tenfold, depending on weather conditions and the source of smoke. Therefore, measurements performed by a network of sensors, even of worse quality, are much more representative than those conducted in one spot. The results also indicated the method of detecting a sudden increase in air pollutants. In the case of smokiness, the difference between the mean and median indications of the PM sensor increases even up to 400 µg/m3 over a 5 min time window. Information from this comparison suggests a sudden deterioration in air quality and can allow for quick intervention to protect people's health. This method can be used in protection systems where fast detection of anomalies is necessary.

2.
Sensors (Basel) ; 18(12)2018 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-30477133

RESUMO

Glass pH electrodes are still successfully applied in the chemical and environmental industry. During their long-term use, periodic calibration is required to maintain the required accuracy of measurements because the parameters of the electrodes change over time. This work presents an aging of 11 pH electrodes within approximately 600 days in tap water. During this period, potentials of all electrodes in five buffer solutions were measured 44 times. This allowed determining the aging models of the electrodes. Models in other mediums might be different. Changes in slope, standard potential, hysteresis, and linearity of the characteristics were the objects of observations. A method for predicting electrode parameters is proposed. Furthermore, the procedure for estimating the uncertainty of pH measurements considering the aging of the electrodes is described. As a result of this work, a model of the aging process of pH electrodes in tap water can be constructed and subsequently, the measurement accuracy in the periods between calibrations can be improved.

3.
Sensors (Basel) ; 18(6)2018 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-29895807

RESUMO

An assessment of measurement uncertainty is a task, which has to be the final step of every chemical assay. Apart from a commonly applied typical assessment method, Monte Carlo (MC) simulations may be used. The simulations are frequently performed by a computer program, which has to be written, and therefore some programming skills are required. It is also possible to use a commonly known spreadsheet and perform such simulations without writing any code. Commercial programs dedicated for the purpose are also available. In order to show the advantages and disadvantages of the ways of uncertainty evaluation, i.e., the typical method, the MC method implemented in a program and in a spreadsheet, and commercial programs, a case of pH measurement after two-point calibration is considered in this article. The ways differ in the required mathematical transformations, degrees of software usage, the time spent for the uncertainty calculations, and cost of software. Since analysts may have different mathematical and coding skills and practice, it is impossible to point out the best way of uncertainty assessment-all of them are just as good and give comparable assessments.

4.
Talanta ; 98: 28-33, 2012 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-22939124

RESUMO

In this paper a novel calibration procedure for the parameter determination of ion-selective electrodes used in an array is described. Commonly used procedures require a large number of standards to determine the parameters based on the Nicolsky-Eisenman model. The elaborated procedure reduces the number of standards to a minimum by using a standard containing a mixture of ions instead of a couple of pure standards. This paper presents a complete calibration procedure, which consists of designing the composition of the standards, parameter determination and verification of the calibration results. Comparison of the results obtained by the procedure presented with results obtained by the Two-Point Calibration and Separate Solution methods proves that the accuracies of both procedures are comparable. The outlined procedure can be applied in multicomponent analysers.