Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 13(3): 1224-1242, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35414995

RESUMO

Multispectral imaging provides valuable information on tissue composition such as hemoglobin oxygen saturation. However, the real-time application of this technique in interventional medicine can be challenging due to the long acquisition times needed for large amounts of hyperspectral data with hundreds of bands. While this challenge can partially be addressed by choosing a discriminative subset of bands, the band selection methods proposed to date are mainly restricted by the availability of often hard to obtain reference measurements. We address this bottleneck with a new approach to band selection that leverages highly accurate Monte Carlo (MC) simulations. We hypothesize that a so chosen small subset of bands can reproduce or even improve upon the results of a quasi continuous spectral measurement. We further investigate whether novel domain adaptation techniques can address the inevitable domain shift stemming from the use of simulations. Initial results based on in silico and in vivo experiments suggest that 10-20 bands are sufficient to closely reproduce results from spectral measurements with 101 bands in the 500-700 nm range. The investigated domain adaptation technique, which only requires unlabeled in vivo measurements, yielded better results than the pure in silico band selection method. Overall, our method could guide development of fast multispectral imaging systems suited for interventional use without relying on complex hardware setups or manually labeled data.

2.
Int J Comput Assist Radiol Surg ; 15(7): 1117-1125, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32535848

RESUMO

PURPOSE: Live intra-operative functional imaging has multiple potential clinical applications, such as localization of ischemia, assessment of organ transplantation success and perfusion monitoring. Recent research has shown that live monitoring of functional tissue properties, such as tissue oxygenation and blood volume fraction, is possible using multispectral imaging in laparoscopic surgery. While the illuminant spectrum is typically kept constant in laparoscopic surgery and can thus be estimated from preoperative calibration images, a key challenge in open surgery originates from the dynamic changes of lighting conditions. METHODS: The present paper addresses this challenge with a novel approach to light source calibration based on specular highlight analysis. It involves the acquisition of low-exposure time images serving as a basis for recovering the illuminant spectrum from pixels that contain a dominant specular reflectance component. RESULTS: Comprehensive in silico and in vivo experiments with a range of different light sources demonstrate that our approach enables an accurate and robust recovery of the illuminant spectrum in the field of view of the camera, which results in reduced errors with respect to the estimation of functional tissue properties. Our approach further outperforms state-of-the-art methods proposed in the field of computer vision. CONCLUSION: Our results suggest that low-exposure multispectral images are well suited for light source calibration via specular highlight analysis. This work thus provides an important first step toward live functional imaging in open surgery.


Assuntos
Laparoscopia/métodos , Iluminação , Monitorização Intraoperatória/métodos , Calibragem , Simulação por Computador , Humanos
3.
IEEE Trans Biomed Eng ; 65(11): 2649-2659, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29993443

RESUMO

OBJECTIVE: Surgical data science is evolving into a research field that aims to observe everything occurring within and around the treatment process to provide situation-aware data-driven assistance. In the context of endoscopic video analysis, the accurate classification of organs in the field of view of the camera proffers a technical challenge. Herein, we propose a new approach to anatomical structure classification and image tagging that features an intrinsic measure of confidence to estimate its own performance with high reliability and which can be applied to both RGB and multispectral imaging (MI) data. METHODS: Organ recognition is performed using a superpixel classification strategy based on textural and reflectance information. Classification confidence is estimated by analyzing the dispersion of class probabilities. Assessment of the proposed technology is performed through a comprehensive in vivo study with seven pigs. RESULTS: When applied to image tagging, mean accuracy in our experiments increased from 65% (RGB) and 80% (MI) to 90% (RGB) and 96% (MI) with the confidence measure. CONCLUSION: Results showed that the confidence measure had a significant influence on the classification accuracy, and MI data are better suited for anatomical structure labeling than RGB data. SIGNIFICANCE: This paper significantly enhances the state of art in automatic labeling of endoscopic videos by introducing the use of the confidence metric, and by being the first study to use MI data for in vivo laparoscopic tissue classification. The data of our experiments will be released as the first in vivo MI dataset upon publication of this paper.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório/métodos , Sistema Digestório/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Laparoscopia/métodos , Animais , Baço/diagnóstico por imagem , Suínos , Gravação em Vídeo
4.
J Med Imaging (Bellingham) ; 4(1): 015001, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28149926

RESUMO

Intraoperative tissue classification is one of the prerequisites for providing context-aware visualization in computer-assisted minimally invasive surgeries. As many anatomical structures are difficult to differentiate in conventional RGB medical images, we propose a classification method based on multispectral image patches. In a comprehensive ex vivo study through statistical analysis, we show that (1) multispectral imaging data are superior to RGB data for organ tissue classification when used in conjunction with widely applied feature descriptors and (2) combining the tissue texture with the reflectance spectrum improves the classification performance. The classifier reaches an accuracy of 98.4% on our dataset. Multispectral tissue analysis could thus evolve as a key enabling technique in computer-assisted laparoscopy.

5.
Int J Comput Assist Radiol Surg ; 11(6): 909-17, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27142459

RESUMO

PURPOSE: Multispectral imaging can provide reflectance measurements at multiple spectral bands for each image pixel. These measurements can be used for estimation of important physiological parameters, such as oxygenation, which can provide indicators for the success of surgical treatment or the presence of abnormal tissue. The goal of this work was to develop a method to estimate physiological parameters in an accurate and rapid manner suited for modern high-resolution laparoscopic images. METHODS: While previous methods for oxygenation estimation are based on either simple linear methods or complex model-based approaches exclusively suited for off-line processing, we propose a new approach that combines the high accuracy of model-based approaches with the speed and robustness of modern machine learning methods. Our concept is based on training random forest regressors using reflectance spectra generated with Monte Carlo simulations. RESULTS: According to extensive in silico and in vivo experiments, the method features higher accuracy and robustness than state-of-the-art online methods and is orders of magnitude faster than other nonlinear regression based methods. CONCLUSION: Our current implementation allows for near real-time oxygenation estimation from megapixel multispectral images and is thus well suited for online tissue analysis.


Assuntos
Diagnóstico por Imagem/métodos , Hemoglobinas/química , Processamento de Imagem Assistida por Computador/métodos , Análise Espectral/métodos , Simulação por Computador , Humanos , Método de Monte Carlo , Oxigênio/química , Consumo de Oxigênio , Análise de Regressão , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...