1.
J Pharm Biomed Anal ; 43(4): 1297-305, 2007 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-17166686

RESUMO

Real time release (RTR) of products is a new paradigm in the pharmaceutical industry. An RTR system assures that when the last manufacturing step is passed all the final release criteria are met. Various types of models can be used within the RTR framework. For each RTR system, the monitoring capability, control capability and RTR capability need to be tested. This paper presents some practical examples within the RTR framework using near-infrared and process data obtained from a tablet manufacturing process.


Assuntos
Química Farmacêutica/métodos , Composição de Medicamentos , Espectrofotometria Infravermelho/métodos , Comprimidos/química , Tecnologia Farmacêutica , Modelos Estatísticos
2.
J Pharm Biomed Anal ; 41(1): 26-35, 2006 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-16289623

RESUMO

Determination of homogeneous mixing of the active pharmaceutical ingredient (API) is an important in-process control within the manufacturing of solid dosage forms. In this paper two new near-infrared (NIR) based methods were presented; a qualitative and a quantitative method. Both methods are based on the calculation of net analyte signal (NAS) models which were very easy to develop, specific with respect to the API and required no additional reference analysis. Using a well-mixed batch as a 'golden standard' batch, control charts were developed and used for monitoring the homogeneity of other batches with NIR. The methods were fast, easy to use, non-destructive and provided statistical tests of homogeneity. A mixing study was characterized with the two methods and the methods were validated by comparison with traditional HPLC analysis.


Assuntos
Química Farmacêutica/métodos , Espectrofotometria Infravermelho/métodos , Tecnologia Farmacêutica/métodos , Cromatografia Líquida de Alta Pressão/métodos , Composição de Medicamentos , Modelos Estatísticos , Preparações Farmacêuticas/análise , Reprodutibilidade dos Testes , Fatores de Tempo
3.
Anal Chem ; 77(22): 7103-14, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16285655

RESUMO

Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is separated from the remaining systematic variation due to all other compounds in the matrix. This enhances the ability to flag products out of statistical control. Using control charts, the analyte content, variation of other compounds, and residual variation can be monitored. As an example, NAS-SQC is used to appreciate the control content uniformity of a commercially available pharmaceutical tablet product measured with near-infrared spectroscopy. Using the NAS chart, the active pharmaceutical ingredient (API) content is easily monitored for new tablets. However, since quality is a multivariate property, other quality parameters of the tablets are also monitored simultaneously. It will be demonstrated that, besides the API content, the water content of the tablets as well as the homogeneity of the other compounds is monitored.


Assuntos
Técnicas de Química Analítica/métodos , Técnicas de Química Analítica/normas , Computadores , Modelos Químicos , Controle de Qualidade , Análise Espectral
4.
Appl Spectrosc ; 58(3): 264-71, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15035705

RESUMO

Preprocessing of near-infrared spectra to remove unwanted, i.e., non-related spectral variation and selection of informative wavelengths is considered to be a crucial step prior to the construction of a quantitative calibration model. The standard methodology when comparing various preprocessing techniques and selecting different wavelengths is to compare prediction statistics computed with an independent set of data not used to make the actual calibration model. When the errors of reference value are large, no such values are available at all, or only a limited number of samples are available, other methods exist to evaluate the preprocessing method and wavelength selection. In this work we present a new indicator (SE) that only requires blank sample spectra, i.e., spectra of samples that are mixtures of the interfering constituents (everything except the analyte), a pure analyte spectrum, or alternatively, a sample spectrum where the analyte is present. The indicator is based on computing the net analyte signal of the analyte and the total error, i.e., instrumental noise and bias. By comparing the indicator values when different preprocessing techniques and wavelength selections are applied to the spectra, the optimal preprocessing technique and the optimal wavelength selection can be determined without knowledge of reference values, i.e., it minimizes the non-related spectral variation. The SE indicator is compared to two other indicators that also use net analyte signal computations. To demonstrate the feasibility of the SE indicator, two near-infrared spectral data sets from the pharmaceutical industry were used, i.e., diffuse reflectance spectra of powder samples and transmission spectra of tablets. Especially in pharmaceutical spectroscopic applications, it is expected beforehand that the non-related spectral variation is rather large and it is important to remove it. The indicator gave excellent results with respect to wavelength selection and optimal preprocessing. The SE indicator performs better than the two other indicators, and it is also applicable to other situations where the Beer-Lambert law is valid.


Assuntos
Química Farmacêutica/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Calibragem , Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Química Farmacêutica/instrumentação , Preparações Farmacêuticas/química , Pós , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Comprimidos
5.
J Pharm Biomed Anal ; 14(11): 1495-503, 1996 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8877855

RESUMO

Near-infrared spectrometry (NIR) was used to quantify metroprolol succinate in controlled release tablets. Metoprolol tablets were made according to an experimental design using different strengths around a central strength of 47.5 mg per tablet. A comparison was made between NIR in the diffuse reflectance mode and the transmission mode. This showed that, although a narrower wavelength range was available in the transmission mode, predictions were much better for models based on transmission spectra than for models based on diffuse reflectance spectra. The main reason for this is that in the reflectance mode NIR spectrometry is very sensitive to the inhomogeneity of the material, while in the transmission mode this problem is less severe. This is due to the larger volume of the material scanned in the transmission mode compared to that in diffuse reflectance. Spectra were taken before and after the tablets were stored under humid conditions. This allowed the final calibration models to be made more robust towards variations in the amount of water in the tablet. Different batches of metoprolol pellets and microcrystalline cellulose were used during the production of the tablets. this resulted in models that were more robust towards possible batch-to-batch differences in the main constituents.


Assuntos
Metoprolol/análise , Armazenamento de Medicamentos , Umidade , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Comprimidos/análise
6.
Anal Chem ; 68(17): 2766-70, 1996 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21619349

RESUMO

Real-time studies of the dynamic processes that take place during isotachophoresis (ITP) were performed. The experimental arrangement utilized was a real-time fluorescence imaging system based on a dye laser at 488 nm, pumped by a XeCl excimer laser. Fluorescence emitted from the migrating sample molecules was recorded by an image-intensified, thermoelectrically cooled CCD camera. The camera signals were processed by a computer and displayed on a screen in real time, allowing the ITP concentration to be monitored continuously. Real-time analysis provided additional information concerning ITP hardly obtainable using conventional detection systems or by theoretical calculations. Such experimental data can be evaluated and be compared with theoretical calculations. Information obtained by this detection technique is useful if ITP is to be used, for example as an on-line preconcentration technique in combination with capillary zone electrophoresis.

7.
Chirality ; 6(7): 596-604, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7986673

RESUMO

In order to obtain milligram amounts of the enantiomers of a series of compounds to be tested for binding to the melatonin binding site, a system for semipreparative enantiomeric separation was set up using tri-acetylcellulose as the chiral stationary phase. Interactions of this class of compounds with tri-acetylcellulose were examined on an analytical scale with a series of 20 compounds. Apparently, both steric and electrostatic interactions determine retention behavior on tri-acetylcellulose. Semipreparative separations were carried out for a subset of seven compounds. The purity of the first eluting enantiomer usually was around 99%, whereas the purity of the second eluting enantiomer was slightly less. The system described is easy to use and has the major advantage that a series of compounds can be separated with one technique. The purities obtained are sufficient for a first screen of their affinity.


Assuntos
Celulose/análogos & derivados , Melatonina/análogos & derivados , Melatonina/metabolismo , Receptores de Superfície Celular/metabolismo , Sítios de Ligação , Cromatografia Líquida de Alta Pressão/métodos , Indicadores e Reagentes , Melatonina/isolamento & purificação , Receptores de Melatonina , Estereoisomerismo , Relação Estrutura-Atividade
8.
Pharm World Sci ; 15(1): 10-6, 1993 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-8485501

RESUMO

In this review we describe the impact of chirality on drug development and registration in the United States, Japan and the European Community. Enantiomers may have differences in their pharmacological profiles, and, therefore, chiral drugs ask for special analytical and pharmacological attention during their development. However, the registration authorities have no clear policy towards the registration of chiral drugs. The absence of a clear policy regarding chirality causes a great deal of confusion and frustration at various levels and is not in the interest of industries developing newer and more beneficial drugs.


Assuntos
Preparações Farmacêuticas/química , Estereoisomerismo , União Europeia , Japão , Legislação de Medicamentos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...