1.
J Clin Sleep Med ; 13(8): 1009-1012, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28633720

RESUMO

STUDY OBJECTIVES: To determine if the application of continuous negative external pressure (cNEP) is effective and safe in individuals with obstructive sleep apnea (OSA) during an overnight in-laboratory sleep study. METHODS: A prospective, open-label pilot study in subjects with documented OSA recruited from the patient population at one sleep clinic. The intervention was application and titration of cNEP during overnight polysomnography. RESULTS: Of the 15 subjects studied (mean apnea-hypopnea index [AHI] at baseline, 43.9 events/h), 13 (87%) were responders to cNEP: 9 had an excellent response (AHI < 5 events/h) and 4 had a partial response (AHI < 50% baseline and < 15 events/h). Three minor, self-limited adverse events occurred, which appeared related to contact pressure of the cNEP device on the skin. CONCLUSIONS: In this pilot study, cNEP appears to be safe and effective during short-term use in subjects with OSA. Further studies are warranted.


Assuntos
Respiração Artificial/métodos , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Polissonografia , Estudos Prospectivos , Respiração Artificial/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...