Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mater Sci Mater Med ; 28(3): 53, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28197824

RESUMO

Custom-designed patient-specific implants and reconstruction plates are to date commonly manufactured using two different additive manufacturing (AM) technologies: direct metal laser sintering (DMLS) and electron beam melting (EBM). The purpose of this investigation was to characterize the surface structure and to assess the cytotoxicity of titanium alloys processed using DMLS and EBM technologies as the existing information on these issues is scarce. "Processed" and "polished" DMLS and EBM disks were assessed. Microscopic examination revealed titanium alloy particles and surface flaws on the processed materials. These surface flaws were subsequently removed by polishing. Surface roughness of EBM processed titanium was higher than that of DMLS processed. The cytotoxicity results of the DMLS and EBM discs were compared with a "gold standard" commercially available titanium mandible reconstruction plate. The mean cell viability for all discs was 82.6% (range, 77.4 to 89.7) and 83.3% for the control reconstruction plate. The DMLS and EBM manufactured titanium plates were non-cytotoxic both in "processed" and in "polished" forms.


Assuntos
Materiais Biocompatíveis/química , Substitutos Ósseos/química , Teste de Materiais/métodos , Titânio/química , Ligas/química , Animais , Sobrevivência Celular , Camundongos , Microscopia Eletrônica de Varredura , Próteses e Implantes , Propriedades de Superfície
2.
J Emerg Med ; 51(6): 721-724, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27687173

RESUMO

BACKGROUND: Over the last decades, dental implants have become increasingly popular in the prosthetic rehabilitation of patients. This has subsequently led to an increase of perioperative complications. Obstruction of the airway as a result of a floor of mouth hematoma after dental implant surgery is a rare but life-threatening complication. CASE REPORT: A 62-year-old man presented to the emergency department with a compromised airway caused by a hematoma in the floor of the mouth that occurred during dental implant surgery in the edentulous anterior mandible. Computed tomography angiography images revealed an elevation of the floor of mouth with subsequent occlusion of the airway. In addition, a perforation of the lingual mandibular cortical plate was observed that was caused by two malpositioned dental implants. Awake fiberoptic intubation was immediately performed, the two malpositioned dental implants were subsequently removed, and the patient was extubated after 3 days. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Perforation of the lingual mandibular cortical plate during dental implant surgery can lead to life-threatening bleeding in the floor of the mouth. This condition can be successfully treated by awake fiberoptic intubation and, if necessary, the malpositioned dental implants can be subsequently removed.


Assuntos
Manuseio das Vias Aéreas , Obstrução das Vias Respiratórias/terapia , Implantes Dentários/efeitos adversos , Hematoma/etiologia , Doenças da Boca/etiologia , Complicações Pós-Operatórias/terapia , Doença Aguda , Obstrução das Vias Respiratórias/etiologia , Humanos , Intubação Intratraqueal , Masculino , Mandíbula/cirurgia , Pessoa de Meia-Idade , Soalho Bucal , Complicações Pós-Operatórias/etiologia
3.
J Appl Clin Med Phys ; 16(4): 266­278, 2015 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-26219008

RESUMO

The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in vivo measurements (<1.7 mGy) the sensitivity is too low.


Assuntos
Antropometria , Anormalidades Maxilofaciais/radioterapia , Imagens de Fantasmas , Fótons , Semicondutores , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Cabeça/diagnóstico por imagem , Humanos , Doses de Radiação , Radiografia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...