Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hear Res ; 379: 103-116, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31150955

RESUMO

Many users of bilateral cochlear implants (BiCIs) localize sound sources less accurately than do people with normal hearing. This may be partly due to using two independently functioning CIs with fixed compression, which distorts and/or reduces interaural level differences (ILDs). Here, we investigate the potential benefits of using binaurally coupled, dynamic compression inspired by the medial olivocochlear reflex; an approach termed "the MOC strategy" (Lopez-Poveda et al., 2016, Ear Hear 37:e138-e148). Twelve BiCI users were asked to localize wideband (125-6000 Hz) noise tokens in a virtual horizontal plane. Stimuli were processed through a standard (STD) sound processing strategy (i.e., involving two independently functioning sound processors with fixed compression) and three different implementations of the MOC strategy: one with fast (MOC1) and two with slower contralateral control of compression (MOC2 and MOC3). The MOC1 and MOC2 strategies had effectively greater inhibition in the higher than in the lower frequency channels, while the MOC3 strategy had slightly greater inhibition in the lower than in the higher frequency channels. Localization was most accurate with the MOC1 strategy, presumably because it provided the largest and less ambiguous ILDs. The angle error improved slightly from 25.3° with the STD strategy to 22.7° with the MOC1 strategy. The improvement in localization ability over the STD strategy disappeared when the contralateral control of compression was made slower, presumably because stimuli were too short (200 ms) for the slower contralateral inhibition to enhance ILDs. Results suggest that some MOC implementations hold promise for improving not only speech-in-noise intelligibility, as shown elsewhere, but also sound source lateralization.


Assuntos
Implantes Cocleares , Localização de Som/fisiologia , Estimulação Acústica , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Membrana Basilar/fisiopatologia , Implantes Cocleares/estatística & dados numéricos , Compressão de Dados , Processamento Eletrônico de Dados , Feminino , Perda Auditiva Bilateral/fisiopatologia , Perda Auditiva Bilateral/reabilitação , Humanos , Masculino , Pessoa de Meia-Idade , Órgão Espiral/fisiopatologia , Reflexo Acústico/fisiologia , Complexo Olivar Superior/fisiopatologia
2.
Hear Res ; 348: 134-137, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28188882

RESUMO

We have recently proposed a binaural cochlear implant (CI) sound processing strategy inspired by the contralateral medial olivocochlear reflex (the MOC strategy) and shown that it improves intelligibility in steady-state noise (Lopez-Poveda et al., 2016, Ear Hear 37:e138-e148). The aim here was to evaluate possible speech-reception benefits of the MOC strategy for speech maskers, a more natural type of interferer. Speech reception thresholds (SRTs) were measured in six bilateral and two single-sided deaf CI users with the MOC strategy and with a standard (STD) strategy. SRTs were measured in unilateral and bilateral listening conditions, and for target and masker stimuli located at azimuthal angles of (0°, 0°), (-15°, +15°), and (-90°, +90°). Mean SRTs were 2-5 dB better with the MOC than with the STD strategy for spatially separated target and masker sources. For bilateral CI users, the MOC strategy (1) facilitated the intelligibility of speech in competition with spatially separated speech maskers in both unilateral and bilateral listening conditions; and (2) led to an overall improvement in spatial release from masking in the two listening conditions. Insofar as speech is a more natural type of interferer than steady-state noise, the present results suggest that the MOC strategy holds potential for promising outcomes for CI users.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Audição , Inteligibilidade da Fala , Adulto , Idoso de 80 Anos ou mais , Limiar Auditivo , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Mascaramento Perceptivo , Som , Localização de Som , Fala , Percepção da Fala , Teste do Limiar de Recepção da Fala , Resultado do Tratamento
3.
Adv Exp Med Biol ; 894: 105-114, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27080651

RESUMO

Our two ears do not function as fixed and independent sound receptors; their functioning is coupled and dynamically adjusted via the contralateral medial olivocochlear efferent reflex (MOCR). The MOCR possibly facilitates speech recognition in noisy environments. Such a role, however, is yet to be demonstrated because selective deactivation of the reflex during natural acoustic listening has not been possible for human subjects up until now. Here, we propose that this and other roles of the MOCR may be elucidated using the unique stimulus controls provided by cochlear implants (CIs). Pairs of sound processors were constructed to mimic or not mimic the effects of the contralateral MOCR with CIs. For the non-mimicking condition (STD strategy), the two processors in a pair functioned independently of each other. When configured to mimic the effects of the MOCR (MOC strategy), however, the two processors communicated with each other and the amount of compression in a given frequency channel of each processor in the pair decreased with increases in the output energy from the contralateral processor. The analysis of output signals from the STD and MOC strategies suggests that in natural binaural listening, the MOCR possibly causes a small reduction of audibility but enhances frequency-specific inter-aural level differences and the segregation of spatially non-overlapping sound sources. The proposed MOC strategy could improve the performance of CI and hearing-aid users.


Assuntos
Cóclea/fisiologia , Implantes Cocleares , Audição/fisiologia , Reflexo Acústico/fisiologia , Humanos
4.
Ear Hear ; 37(3): e138-48, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26862711

RESUMO

OBJECTIVES: In natural hearing, cochlear mechanical compression is dynamically adjusted via the efferent medial olivocochlear reflex (MOCR). These adjustments probably help understanding speech in noisy environments and are not available to the users of current cochlear implants (CIs). The aims of the present study are to: (1) present a binaural CI sound processing strategy inspired by the control of cochlear compression provided by the contralateral MOCR in natural hearing; and (2) assess the benefits of the new strategy for understanding speech presented in competition with steady noise with a speech-like spectrum in various spatial configurations of the speech and noise sources. DESIGN: Pairs of CI sound processors (one per ear) were constructed to mimic or not mimic the effects of the contralateral MOCR on compression. For the nonmimicking condition (standard strategy or STD), the two processors in a pair functioned similarly to standard clinical processors (i.e., with fixed back-end compression and independently of each other). When configured to mimic the effects of the MOCR (MOC strategy), the two processors communicated with each other and the amount of back-end compression in a given frequency channel of each processor in the pair decreased/increased dynamically (so that output levels dropped/increased) with increases/decreases in the output energy from the corresponding frequency channel in the contralateral processor. Speech reception thresholds in speech-shaped noise were measured for 3 bilateral CI users and 2 single-sided deaf unilateral CI users. Thresholds were compared for the STD and MOC strategies in unilateral and bilateral listening conditions and for three spatial configurations of the speech and noise sources in simulated free-field conditions: speech and noise sources colocated in front of the listener, speech on the left ear with noise in front of the listener, and speech on the left ear with noise on the right ear. In both bilateral and unilateral listening, the electrical stimulus delivered to the test ear(s) was always calculated as if the listeners were wearing bilateral processors. RESULTS: In both unilateral and bilateral listening conditions, mean speech reception thresholds were comparable with the two strategies for colocated speech and noise sources, but were at least 2 dB lower (better) with the MOC than with the STD strategy for spatially separated speech and noise sources. In unilateral listening conditions, mean thresholds improved with increasing the spatial separation between the speech and noise sources regardless of the strategy but the improvement was significantly greater with the MOC strategy. In bilateral listening conditions, thresholds improved significantly with increasing the speech-noise spatial separation only with the MOC strategy. CONCLUSIONS: The MOC strategy (1) significantly improved the intelligibility of speech presented in competition with a spatially separated noise source, both in unilateral and bilateral listening conditions; (2) produced significant spatial release from masking in bilateral listening conditions, something that did not occur with fixed compression; and (3) enhanced spatial release from masking in unilateral listening conditions. The MOC strategy as implemented here, or a modified version of it, may be usefully applied in CIs and in hearing aids.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez/reabilitação , Reflexo , Percepção da Fala , Feminino , Humanos , Masculino , Software
5.
Ear Hear ; 26(4 Suppl): 73S-81S, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16082269

RESUMO

Two new approaches to the design of speech processors for cochlear implants are described. The first aims to represent "fine structure" or "fine frequency" information in a way that it can be perceived and used by patients, and the second aims to provide a closer mimicking than was previously possible of the signal processing that occurs in the normal cochlea.


Assuntos
Estimulação Acústica/instrumentação , Implantes Cocleares , Perda Auditiva/reabilitação , Percepção Auditiva , Cóclea/fisiologia , Humanos , Modelos Teóricos , Desenho de Prótese , Ajuste de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...