Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
2.
Radiology ; 307(5): e222855, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37367445

RESUMO

Background Various limitations have impacted research evaluating reader agreement for Liver Imaging Reporting and Data System (LI-RADS). Purpose To assess reader agreement of LI-RADS in an international multicenter multireader setting using scrollable images. Materials and Methods This retrospective study used deidentified clinical multiphase CT and MRI and reports with at least one untreated observation from six institutions and three countries; only qualifying examinations were submitted. Examination dates were October 2017 to August 2018 at the coordinating center. One untreated observation per examination was randomly selected using observation identifiers, and its clinically assigned features were extracted from the report. The corresponding LI-RADS version 2018 category was computed as a rescored clinical read. Each examination was randomly assigned to two of 43 research readers who independently scored the observation. Agreement for an ordinal modified four-category LI-RADS scale (LR-1, definitely benign; LR-2, probably benign; LR-3, intermediate probability of malignancy; LR-4, probably hepatocellular carcinoma [HCC]; LR-5, definitely HCC; LR-M, probably malignant but not HCC specific; and LR-TIV, tumor in vein) was computed using intraclass correlation coefficients (ICCs). Agreement was also computed for dichotomized malignancy (LR-4, LR-5, LR-M, and LR-TIV), LR-5, and LR-M. Agreement was compared between research-versus-research reads and research-versus-clinical reads. Results The study population consisted of 484 patients (mean age, 62 years ± 10 [SD]; 156 women; 93 CT examinations, 391 MRI examinations). ICCs for ordinal LI-RADS, dichotomized malignancy, LR-5, and LR-M were 0.68 (95% CI: 0.61, 0.73), 0.63 (95% CI: 0.55, 0.70), 0.58 (95% CI: 0.50, 0.66), and 0.46 (95% CI: 0.31, 0.61) respectively. Research-versus-research reader agreement was higher than research-versus-clinical agreement for modified four-category LI-RADS (ICC, 0.68 vs 0.62, respectively; P = .03) and for dichotomized malignancy (ICC, 0.63 vs 0.53, respectively; P = .005), but not for LR-5 (P = .14) or LR-M (P = .94). Conclusion There was moderate agreement for LI-RADS version 2018 overall. For some comparisons, research-versus-research reader agreement was higher than research-versus-clinical reader agreement, indicating differences between the clinical and research environments that warrant further study. © RSNA, 2023 Supplemental material is available for this article. See also the editorials by Johnson and Galgano and Smith in this issue.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Feminino , Pessoa de Meia-Idade , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X , Meios de Contraste , Sensibilidade e Especificidade
3.
Abdom Radiol (NY) ; 48(8): 2557-2569, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37246973

RESUMO

PURPOSE: To assess inter-observer agreement and accuracy of LI-RADS v2018 for differentiating tumor in vein (TIV) from bland thrombus on gadoxetic acid-enhanced magnetic resonance imaging (Gx-MRI). Secondarily, to determine whether a multi-feature model improves accuracy compared to LI-RADS. METHODS: We retrospectively identified consecutive patients at risk for hepatocellular carcinoma with venous occlusion(s) reported on Gx-MRI. Five radiologists independently classified each occlusion as TIV or bland thrombus using the LI-RADS TIV criterion (enhancing soft tissue in vein). They also evaluated imaging features suggestive of TIV or bland thrombus. Intra-class correlation coefficient (ICC) was calculated for individual features. A multi-feature model was developed based on consensus scores of features with > 5% consensus prevalence and > 0.40 ICC. Sensitivity and specificity of the LI-RADS criterion and of the cross-validated multi-feature model were compared. RESULTS: Ninety-eight patients with 103 venous occlusions (58 TIV, 45 bland thrombus) were included. The LI-RADS criterion provided 0.63 ICC and, depending on the reader, 0.62-0.93 sensitivity and 0.87-1.00 specificity. Five other features had > 5% consensus prevalence and > 0.40 ICC, including three LI-RADS suggestive features and two non-LI-RADS features. The optimal multi-feature model incorporated the LI-RADS criterion and one LI-RADS suggestive feature (occluded or obscured vein contiguous with malignant parenchymal mass). After cross-validation, the multi-feature model did not improve sensitivity or specificity compared to the LI-RADS criterion (P = 0.23 and 0.25, respectively). CONCLUSION: Using Gx-MRI, the LI-RADS criterion for TIV provides substantial inter-observer agreement, variable sensitivity, and high specificity for differentiating TIV from bland thrombus. A cross-validated multi-feature model did not improve diagnostic performance.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Trombose , Doenças Vasculares , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Variações Dependentes do Observador , Meios de Contraste , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Trombose/diagnóstico por imagem
5.
J Hepatol ; 78(2): 238-246, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36368598

RESUMO

BACKGROUND & AIMS: Non-alcoholic steatohepatitis (NASH) is prevalent in adults with obesity and can progress to cirrhosis. In a secondary analysis of prospectively acquired data from the multicenter, randomized, placebo-controlled FLINT trial, we investigated the relationship between reduction in adipose tissue compartment volumes and hepatic histologic improvement. METHODS: Adult participants in the FLINT trial with paired liver biopsies and abdominal MRI exams at baseline and end-of-treatment (72 weeks) were included (n = 76). Adipose tissue compartment volumes were obtained using MRI. RESULTS: Treatment and placebo groups did not differ in baseline adipose tissue volumes, or in change in adipose tissue volumes longitudinally (p = 0.107 to 0.745). Deep subcutaneous adipose tissue (dSAT) and visceral adipose tissue volume reductions were associated with histologic improvement in NASH (i.e., NAS [non-alcoholic fatty liver disease activity score] reductions of ≥2 points, at least 1 point from lobular inflammation and hepatocellular ballooning, and no worsening of fibrosis) (p = 0.031, and 0.030, respectively). In a stepwise logistic regression procedure, which included demographics, treatment group, baseline histology, baseline and changes in adipose tissue volumes, MRI hepatic proton density fat fraction (PDFF), and serum aminotransferases as potential predictors, reductions in dSAT and PDFF were associated with histologic improvement in NASH (regression coefficient = -2.001 and -0.083, p = 0.044 and 0.033, respectively). CONCLUSIONS: In adults with NASH in the FLINT trial, those with greater longitudinal reductions in dSAT and potentially visceral adipose tissue volumes showed greater hepatic histologic improvements, independent of reductions in hepatic PDFF. CLINICAL TRIAL NUMBER: NCT01265498. IMPACT AND IMPLICATIONS: Although central obesity has been identified as a risk factor for obesity-related disorders including insulin resistance and cardiovascular disease, the role of central obesity in non-alcoholic steatohepatitis (NASH) warrants further clarification. Our results highlight that a reduction in central obesity, specifically deep subcutaneous adipose tissue and visceral adipose tissue, may be related to histologic improvement in NASH. The findings from this analysis should increase awareness of the importance of lifestyle intervention in NASH for clinical researchers and clinicians. Future studies and clinical practice may design interventions that assess the reduction of deep subcutaneous adipose tissue and visceral adipose tissue as outcome measures, rather than simply weight reduction.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Adulto , Humanos , Hepatopatia Gordurosa não Alcoólica/patologia , Obesidade Abdominal , Fígado/diagnóstico por imagem , Fígado/patologia , Fibrose , Obesidade/complicações , Obesidade/patologia , Gordura Abdominal/patologia , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/patologia
6.
Magn Reson Med ; 88(4): 1794-1805, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35611691

RESUMO

PURPOSE: To assess feasibility and accuracy of point-of-care (POC) NMR-proton density fat fraction (PDFF) in phantoms and in a human pilot study in a POC setting. METHODS: POC NMR (LiverScope, Livivos, San Diego CA) PDFF measurements were obtained of certified phantoms with known PDFF values (0%-40%). In an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant prospective human study, a convenience sample of participants from an obesity clinic was enrolled (November 2020 to June 2021). The inclusion criteria required body mass index (BMI) = 27-40 kg/m2 and willingness to undergo POC NMR and MRI-PDFF measurements. Liver PDFF was measured by POC NMR and, within 35 days after, by a confounder corrected CSE MRI PDFF acquisition and reconstruction method. The adverse events were documented and linear regression analyses were performed. RESULTS: POC NMR-PDFF measurements agreed with known phantom PDFF values (R2  = 0.99). Fourteen participants were enrolled in the pilot human study. MRI-PDFF could not be obtained in 4 participants (claustrophobia reaction, n = 3, exceeded size of MR scanner bore, n = 1). POC NMR was unevaluable in 2 participants (insufficient signal penetration depth, n = 1, failure to comply with instructions, n = 1). Technical success was 11 of 13 (85%) for POC NMR PDFF. In 7 participants (4 female; 31-74 years old; median BMI 35 kg/m2 ), MRI-PDFF (range, 2.8%-18.1%), and POC NMR-PDFF (range, 3%-25.2%), agreed with R2  = 0.94. POC NMR had no adverse events. CONCLUSION: POC NMR measures PDFF accurately in phantoms and, in a first-in-human pilot study, is feasible and accurate in adults with obesity. Further testing to determine precision and accuracy across larger and more diverse cohorts is needed.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Idoso , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Obesidade/diagnóstico por imagem , Obesidade/patologia , Projetos Piloto , Estudos Prospectivos , Prótons , Reprodutibilidade dos Testes , Tecnologia
7.
Eur Radiol ; 32(4): 2457-2469, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34854929

RESUMO

OBJECTIVES: To compare the diagnostic accuracy of US shear wave elastography (SWE) and magnetic resonance elastography (MRE) for classifying fibrosis stage in patients with nonalcoholic fatty liver disease (NAFLD). METHODS: Patients from a prospective single-center cohort with clinical liver biopsy for known or suspected NAFLD underwent contemporaneous SWE and MRE. AUCs for classifying biopsy-determined liver fibrosis stages ≥ 1, ≥ 2, ≥ 3, and = 4, and their respective performance parameters at cutoffs providing ≥ 90% sensitivity or specificity were compared between SWE and MRE. RESULTS: In total, 100 patients (mean age, 51.8 ± 12.9 years; 46% males; mean BMI 31.6 ± 4.7 kg/m2) with fibrosis stage distribution (stage 0/1/2/3/4) of 43, 36, 5, 10, and 6%, respectively, were included. AUCs (and 95% CIs) for SWE and MRE were 0.65 (0.54-0.76) and 0.81 (0.72-0.89), 0.81 (0.71-0.91) and 0.94 (0.89-1.00), 0.85 (0.74-0.96) and 0.95 (0.89-1.00), and 0.91 (0.79-1.00) and 0.92 (0.83-1.00), for detecting fibrosis stage ≥ 1, ≥ 2, ≥ 3, and = 4, respectively. The differences were significant for detecting fibrosis stage ≥ 1 and ≥ 2 (p < 0.01) but not otherwise. At ≥ 90% sensitivity cutoff, MRE yielded higher specificity than SWE at diagnosing fibrosis stage ≥ 1, ≥ 2, and ≥ 3. At ≥ 90% specificity cutoff, MRE yielded higher sensitivity than SWE at diagnosing fibrosis stage ≥ 1 and ≥ 2. CONCLUSIONS: In adults with NAFLD, MRE was more accurate than SWE in diagnosing stage ≥ 1 and ≥ 2 fibrosis, but not stage ≥ 3 or 4 fibrosis. KEY POINTS: • For detecting any fibrosis or mild fibrosis, MR elastography was significantly more accurate than shear wave elastography. • For detecting advanced fibrosis and cirrhosis, MRE and SWE did not differ significantly in accuracy. • For excluding advanced fibrosis and potentially ruling out the need for biopsy, SWE and MRE did not differ significantly in negative predictive value. • Neither SWE nor MRE had sufficiently high positive predictive value to rule in advanced fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Adulto , Biópsia , Feminino , Fibrose , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos
8.
Eur Radiol ; 32(5): 2937-2948, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34928415

RESUMO

OBJECTIVES: To assess reproducibility and fibrosis classification accuracy of magnetic resonance elastography (MRE)-determined liver stiffness measured manually at two different centers, and by automated analysis software in adults with nonalcoholic fatty liver disease (NAFLD), using histopathology as a reference standard. METHODS: This retrospective, cross-sectional study included 91 adults with NAFLD who underwent liver MRE and biopsy. MRE-determined liver stiffness was measured independently for this analysis by an image analyst at each of two centers using standardized manual analysis methodology, and separately by an automated analysis. Reproducibility was assessed pairwise by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Diagnostic accuracy was assessed by receiver operating characteristic (ROC) analyses. RESULTS: ICC of liver stiffness measurements was 0.95 (95% CI: 0.93, 0.97) between center 1 and center 2 analysts, 0.96 (95% CI: 0.94, 0.97) between the center 1 analyst and automated analysis, and 0.94 (95% CI: 0.91, 0.96) between the center 2 analyst and automated analysis. Mean bias and 95% limits of agreement were 0.06 ± 0.38 kPa between center 1 and center 2 analysts, 0.05 ± 0.32 kPa between the center 1 analyst and automated analysis, and 0.11 ± 0.41 kPa between the center 2 analyst and automated analysis. The area under the ROC curves for the center 1 analyst, center 2 analyst, and automated analysis were 0.834, 0.833, and 0.847 for distinguishing fibrosis stage 0 vs. ≥ 1, and 0.939, 0.947, and 0.940 for distinguishing fibrosis stage ≤ 2 vs. ≥ 3. CONCLUSION: MRE-determined liver stiffness can be measured with high reproducibility and fibrosis classification accuracy at different centers and by an automated analysis. KEY POINTS: • Reproducibility of MRE liver stiffness measurements in adults with nonalcoholic fatty liver disease is high between two experienced centers and between manual and automated analysis methods. • Analysts at two centers had similar high diagnostic accuracy for distinguishing dichotomized fibrosis stages. • Automated analysis provides similar diagnostic accuracy as manual analysis for advanced fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Adulto , Estudos Transversais , Técnicas de Imagem por Elasticidade/métodos , Fibrose , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
9.
Eur Radiol ; 31(11): 8408-8419, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33899143

RESUMO

OBJECTIVES: To investigate associations between histology and hepatic mechanical properties measured using multiparametric magnetic resonance elastography (MRE) in adults with known or suspected nonalcoholic fatty liver disease (NAFLD) without histologic fibrosis. METHODS: This was a retrospective analysis of 88 adults who underwent 3T MR exams including hepatic MRE and MR imaging to estimate proton density fat fraction (MRI-PDFF) within 180 days of liver biopsy. Associations between MRE mechanical properties (mean shear stiffness (|G*|) by 2D and 3D MRE, and storage modulus (G'), loss modulus (G″), wave attenuation (α), and damping ratio (ζ) by 3D MRE) and histologic, demographic and anthropometric data were assessed. RESULTS: In univariate analyses, patients with lobular inflammation grade ≥ 2 had higher 2D |G*| and 3D G″ than those with grade ≤ 1 (p = 0.04). |G*| (both 2D and 3D), G', and G″ increased with age (rho = 0.25 to 0.31; p ≤ 0.03). In multivariable regression analyses, the association between inflammation grade ≥ 2 remained significant for 2D |G*| (p = 0.01) but not for 3D G″ (p = 0.06); age, sex, or BMI did not affect the MRE-inflammation relationship (p > 0.20). CONCLUSIONS: 2D |G*| and 3D G″ were weakly associated with moderate or severe lobular inflammation in patients with known or suspected NAFLD without fibrosis. With further validation and refinement, these properties might become useful biomarkers of inflammation. Age adjustment may help MRE interpretation, at least in patients with early-stage disease. KEY POINTS: • Moderate to severe lobular inflammation was associated with hepatic elevated shear stiffness and elevated loss modulus (p =0.04) in patients with known or suspected NAFLD without liver fibrosis; this suggests that with further technical refinement these MRE-assessed mechanical properties may permit detection of inflammation before the onset of fibrosis in NAFLD. • Increasing age is associated with higher hepatic shear stiffness, and storage and loss moduli (rho = 0.25 to 0.31; p ≤ 0.03); this suggests that age adjustment may help interpret MRE results, at least in patients with early-stage NAFLD.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Biomarcadores , Fibrose , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos , Estudos Retrospectivos
10.
Abdom Radiol (NY) ; 46(7): 3105-3116, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33609166

RESUMO

PURPOSE: To evaluate repeatability of ROI-sampling strategies for quantifying hepatic proton density fat fraction (PDFF) and to assess error relative to the 9-ROI PDFF. METHODS: This was a secondary analysis in subjects with known or suspected nonalcoholic fatty liver disease who underwent MRI for magnitude-based hepatic PDFF quantification. Each subject underwent three exams, each including three acquisitions (nine acquisitions total). An ROI was placed in each hepatic segment on the first acquisition of the first exam and propagated to other acquisitions. PDFF was calculated for each of 511 sampling strategies using every combination of 1, 2, …, all 9 ROIs. Intra- and inter-exam intra-class correlation coefficients (ICCs) and repeatability coefficients (RCs) were estimated for each sampling strategy. Mean absolute error (MAE) was estimated relative to the 9-ROI PDFF. Strategies that sampled both lobes evenly ("balanced") were compared with those that did not ("unbalanced") using two-sample t tests. RESULTS: The 29 enrolled subjects (23 male, mean age 24 years) had mean 9-ROI PDFF 11.8% (1.1-36.3%). With more ROIs, ICCs increased, RCs decreased, and MAE decreased. Of the 60 balanced strategies with 4 ROIs, all (100%) achieved inter- and intra-exam ICCs > 0.998, 55 (92%) achieved intra-exam RC < 1%, 50 (83%) achieved inter-exam RC < 1%, and all (100%) achieved MAE < 1%. Balanced sampling strategies had higher ICCs and lower RCs, and lower MAEs than unbalanced strategies in aggregate (p < 0.001 for comparisons between balanced vs. unbalanced strategies). CONCLUSION: Repeatability improves and error diminishes with more ROIs. Balanced 4-ROI strategies provide high repeatability and low error.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Prótons , Adulto , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
11.
Eur Radiol ; 30(9): 5120-5129, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32318847

RESUMO

PURPOSE: To compare longitudinal hepatic proton density fat fraction (PDFF) changes estimated by magnitude- vs. complex-based chemical-shift-encoded MRI during a weight loss surgery (WLS) program in severely obese adults with biopsy-proven nonalcoholic fatty liver disease (NAFLD). METHODS: This was a secondary analysis of a prospective dual-center longitudinal study of 54 adults (44 women; mean age 52 years; range 27-70 years) with obesity, biopsy-proven NAFLD, and baseline PDFF ≥ 5%, enrolled in a WLS program. PDFF was estimated by confounder-corrected chemical-shift-encoded MRI using magnitude (MRI-M)- and complex (MRI-C)-based techniques at baseline (visit 1), after a 2- to 4-week very low-calorie diet (visit 2), and at 1, 3, and 6 months (visits 3 to 5) after surgery. At each visit, PDFF values estimated by MRI-M and MRI-C were compared by a paired t test. Rates of PDFF change estimated by MRI-M and MRI-C for visits 1 to 3, and for visits 3 to 5 were assessed by Bland-Altman analysis and intraclass correlation coefficients (ICCs). RESULTS: MRI-M PDFF estimates were lower by 0.5-0.7% compared with those of MRI-C at all visits (p < 0.001). There was high agreement and no difference between PDFF change rates estimated by MRI-M vs. MRI-C for visits 1 to 3 (ICC 0.983, 95% CI 0.971, 0.99; bias = - 0.13%, p = 0.22), or visits 3 to 5 (ICC 0.956, 95% CI 0.919-0.977%; bias = 0.03%, p = 0.36). CONCLUSION: Although MRI-M underestimates PDFF compared with MRI-C cross-sectionally, this bias is consistent and MRI-M and MRI-C agree in estimating the rate of hepatic PDFF change longitudinally. KEY POINTS: • MRI-M demonstrates a significant but small and consistent bias (0.5-0.7%; p < 0.001) towards underestimation of PDFF compared with MRI-C at 3 T. • Rates of PDFF change estimated by MRI-M and MRI-C agree closely (ICC 0.96-0.98) in adults with severe obesity and biopsy- proven NAFLD enrolled in a weight loss surgery program. • Our findings support the use of either MRI technique (MRI-M or MRI-C) for clinical care or by individual sites or for multi-center trials that include PDFF change as an endpoint. However, since there is a bias in their measurements, the same technique should be used in any given patient for longitudinal follow-up.


Assuntos
Cirurgia Bariátrica , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Obesidade Mórbida/cirurgia , Adulto , Idoso , Biópsia , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/complicações , Obesidade Mórbida/complicações , Estudos Prospectivos , Prótons
12.
NMR Biomed ; 33(6): e4286, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32128921

RESUMO

The aim of this study was to estimate parameters determining liver triglyceride composition (TC) using 1 H MRS and to assess how TC estimability is affected by proton density fat fraction (PDFF) in adults with nonalcoholic fatty liver disease (NAFLD). In this prospective single-site study, 199 adults with known or suspected NAFLD in whom other causes of liver disease were excluded underwent two 1 H MRS STimulated Echo Acquisition Method (STEAM) sequences at 3 T. A respiratory-gated water-suppressed free breathing sequence (TE 10 ms, 16 signal averages) was used to assess TC in terms of the number of double bonds (ndb) and methylene-interrupted double bonds (nmidb), and a single breath-hold-long TR, multi-TE sequence (TR 3500 ms), which acquired five single average spectra over TE 10-30 ms, was used to estimate liver PDFF. Ndb and nmidb estimability was qualitatively assessed for each case and summarized descriptively. The consistency of ndb and nmidb estimation was examined using ROC analysis. The relationship between ndb and nmidb values and PDFF was presented graphically. Quality-of-fit of ndb and nmidb versus PDFF was evaluated by Pearson-r correlation. A significance level of 0.05 was used. In 263 1 H MRS examinations performed on 199 adult participants, ndb and nmidb were successfully estimated in 7/53 (13.2%) examinations with PDFF < 4%, 13/30 (43.3%) examinations with PDFF between 4% and 7%, 33/41 (80.5%) examinations with PDFF between 7% and 10%, and 124/139 (89.2%) examinations with PDFF > 10% (maximum PDFF 38.1%). Liver TC could be estimated consistently for PDFF > 6.7%. Both ndb and nmidb decreased with increasing PDFF (ndb = 2.83-0.0160·PDFF, r = -0.449, P < 0.0001); nmidb = 0.75-0.0088·PDFF, r = -0.350, P < 0.0001). In a cohort of adults with known or suspected NAFLD, liver TC becomes more saturated as PDFF increases.


Assuntos
Fígado/diagnóstico por imagem , Fígado/metabolismo , Espectroscopia de Prótons por Ressonância Magnética , Prótons , Triglicerídeos/metabolismo , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Adulto Jovem
13.
Abdom Radiol (NY) ; 45(10): 3144-3154, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32193590

RESUMO

OBJECTIVE: To investigate if size measurements of liver observations is more variable in the arterial phase as suggested by LI-RADS and assess potential higher instability in categorization in this particular phase. Secondarily, to assess inter- and intra-reader agreement for size across phases. MATERIALS AND METHODS: Patients with liver cirrhosis who underwent multi-arterial phase MRI between 2017 and 2018 were retrospectively selected. Three radiologists measured liver observations in each phase, independently, in a random order. Mean size between early and late arterial phases (AP), 2, 3 and 10 min delay and the number of observations crossing the LI-RADS size thresholds (10 and 20 mm) per phase were compared using McNemar's test. Reader agreement was evaluated using intraclass correlation coefficient (ICC) and bootstrap-based comparisons. Bonferroni's correction was applied to pairwise comparisons. RESULTS: 94 observations (LR-3, LR-4, LR-5, and LR-M) were included. Mean sizes (mm) were late AP: 19.9 (95% CI 17.2, 24.2), 2 min delay: 19.8 (95% CI 17.1, 24.0), 3 min delay: 19.8 (95% CI 17.2, 24.0), 10 min delay: 20.2 (95% CI 17.5, 24.5) (p = 0.10-0.88). There was no difference between phases in number of observations that could have changed category due to variability in size (p = 0.546-1.000). Inter- and intra-reader agreement was excellent (ICC = 0.952-0.981). CONCLUSION: Measurements of focal liver observations were consistent across all post-contrast imaging phases and we found no higher instability in LI-RADS category in any particular phase. Inter- and intra-reader agreement for size was excellent for each phase. Based on these findings, size measurement could be allowed on any post-contrast phase, including the arterial phase, if deemed appropriate by the radiologist.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Meios de Contraste , Humanos , Estudos Retrospectivos
14.
Abdom Radiol (NY) ; 45(10): 3092-3102, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32052132

RESUMO

PURPOSE: To determine whether LI-RADS ancillary features predict longitudinal LR-3 observation category changes. MATERIALS AND METHODS: This exploratory, retrospective, single-center study with an independent reading center included patients who underwent two or more multiphase CT or MRI examinations for hepatocellular carcinoma assessment between 2011 and 2015. Three readers independently evaluated each observation using CT/MRI LI-RADS v2017, and observations categorized LR-3 using major features only were included in the analysis. Prevalence of major and ancillary features was calculated. After excluding low-frequency (< 5%) features, inter-reader agreement was assessed using intraclass correlation coefficient (ICC). Major and ancillary feature prediction of observation upgrade (to LR-4 or higher) or downgrade (to LR-1 or LR-2) on follow-up imaging was assessed using logistic regression. RESULTS: 141 LR-3 observations in 79 patients were included. Arterial phase hyperenhancement, washout, restricted diffusion, mild-moderate T2 hyperintensity, and hepatobiliary phase hypointensity were frequent enough for further analysis (consensus prevalence 5.0-66.0%). ICCs for inter-reader agreement ranged from 0.18 for restricted diffusion to 0.48 for hepatobiliary phase hypointensity. On follow-up, 40% (57/141) of baseline LR-3 observations remained LR-3. 8% (11/141) were downgraded to LR-2, and 42% (59/141) were downgraded to LR-1. A small number were ultimately upgraded to LR-4 (2%, 3/141) or LR-5 (8%, 11/141). None of the assessed major or ancillary features was significantly associated with observation category change. Longer follow-up time was significantly associated with both observation upgrade and downgrade. CONCLUSION: While numerous ancillary features are described in LI-RADS, most are rarely present and are not useful predictors of LR-3 observation category changes.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Retrospectivos
15.
Abdom Radiol (NY) ; 45(3): 661-671, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31781899

RESUMO

PURPOSE: MRI proton density fat fraction (PDFF) can be calculated using magnitude (MRI-M) or complex (MRI-C) MRI data. The purpose of this study was to identify, assess, and compare the accuracy of common PDFF thresholds for MRI-M and MRI-C for assessing hepatic steatosis in patients with obesity, using histology as reference. METHODS: This two-center prospective study included patients undergoing MRI-C- and MRI-M-PDFF estimations within 3 days before weight loss surgery. Liver biopsy was performed, and histology-determined steatosis grades were used as reference standard. Using receiver operating characteristics (ROC) analysis on data pooled from both methods, single common thresholds for diagnosing and differentiating none or mild (0-1) from moderate to severe steatosis (2-3) were selected as the ones achieving the highest sensitivity while providing at least 90% specificity. Selection methods were cross-validated. Performances were compared using McNemar's tests. RESULTS: Of 81 included patients, 54 (67%) had steatosis. The common PDFF threshold for diagnosing steatosis was 5.4%, which provided a cross-validated 0.88 (95% CI 0.77-0.95) sensitivity and 0.92 (0.75-0.99) specificity for MRI-M and 0.87 sensitivity (0.75-0.94) with 0.81 (0.61-0.93) specificity for MRI-C. The common PDFF threshold to differentiate steatosis grades 0-1 from 2 to 3 was 14.7%, which provided cross-validated 0.86 (95% CI 0.59-0.98) sensitivity and 0.95 (0.87-0.99) specificity for MRI-M and 0.93 sensitivity (0.68-0.99) with 0.97(0.89-0.99) specificity for MRI-C. CONCLUSION: If independently validated, diagnostic thresholds of 5.4% and 14.7% could be adopted for both techniques for detecting and differentiating none to mild from moderate to severe steatosis, respectively, with high diagnostic accuracy.


Assuntos
Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Obesidade/complicações , Adulto , Idoso , Biópsia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos , Prótons , Sensibilidade e Especificidade
16.
Artigo em Inglês | MEDLINE | ID: mdl-30823400

RESUMO

BACKGROUND: E-cigarettes are purchased through multiple channels, including general retail, online, and specialty smoke and vape shops. We examine how e-cigarette users' primary purchase place relates to e-cigarette use and smoking cessation behaviors. METHODS: Probability-based samples of the U.S. population who were current e-cigarette users were surveyed in 2014 (N = 879) and 2016 (N = 743), with responses combined for most analyses. E-cigarette use and smoking cessation behaviors were compared across users' primary purchase place. RESULTS: Higher percentages of vape shop (59.1%) and internet (42.9%) customers were current daily users of e-cigarettes compared to retail (19.7%) and smoke shop (23.2%) customers (p-values < 0.001). Higher percentages of vape shop (40.2%) and internet (35.1%) customers were also former smokers, compared to 17.7% of retail and 19.3% of smoke shop customers (p's < 0.001). Among those smoking 12 months prior to survey, smoking cessation rates were higher for vape shop (22.2%) and internet customers (22.5%) than for retail customers (10.7%, p = 0.010 and p = 0.022, respectively), even though retail customers were more likely to use FDA-approved smoking cessation aids. The percentage of customers purchasing from vape shops increased from 20.4% in 2014 to 37.6% in 2016, surpassing general retail (27.7%) as the most likely channel in 2016. CONCLUSIONS: E-cigarette customers differed in significant ways by channels of purchase, most notably in their smoking cessation behaviors. Previous population studies have relied mostly on retail channel data, which accounted for less than 30% of all products sold by 2016. Future studies of e-cigarette use should consider a broader set of channels.


Assuntos
Comércio/estatística & dados numéricos , Fumantes/estatística & dados numéricos , Abandono do Hábito de Fumar/estatística & dados numéricos , Vaping/epidemiologia , Adulto , Comércio/tendências , Feminino , Humanos , Masculino , Fumar/epidemiologia , Abandono do Hábito de Fumar/métodos , Inquéritos e Questionários , Produtos do Tabaco , Fumar Tabaco , Vaping/tendências
17.
Eur Radiol ; 29(9): 5073-5081, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30809719

RESUMO

OBJECTIVES: This study assesses the risk of progression of Liver Imaging Reporting and Data System (LI-RADS) categories, and the effects of inter-exam changes in modality or radiologist on LI-RADS categorization. METHODS: Clinical LI-RADS v2014 CT and MRI exams at our institution between January 2014 and September 2017 were retrospectively identified. Untreated LR-1, LR-2, LR-3, and LR-4 observations with at least one follow-up exam were included. Three hundred and seventy-two observations in 214 patients (149 male, 65 female, mean age 61 ± 10 years) were included during the study period (715 exams total). Cumulative incidence curves for progression to malignant LI-RADS categories (LR-5 or LR-M) and to LR-4 or higher were generated for each index category and compared using log-rank tests with a resampling extension. Relationships between inter-exam changes in LI-RADS category and modality or radiologist, adjusted for inter-exam time intervals, were modeled using mixed effect logistic regressions. RESULTS: Median inter-exam follow-up interval and total follow-up duration were 123 and 227 days, respectively. Index LR-1, LR-2, LR-3, and LR-4 differed significantly in their cumulative incidences of progression to malignant categories (p < 0.0001), which were 0%, 2%, 7%, and 32% at 6 months, respectively. Index LR-1, LR-2, and LR-3 differed significantly in cumulative incidences of progression to LR-4 or higher (p = 0.003). MRI-MRI exam pairs had more stable LI-RADS categorization compared to CT-CT (OR = 0.460, p = 0.0018). CONCLUSIONS: LI-RADS observations demonstrate increasing risk of progression to malignancy with increasing category ranging from 0% for LR-1 to 32% for LR-4 at 6 months. Inter-exam modality changes are associated with LI-RADS category changes. KEY POINTS: • While the majority of LR-2 observations remain stable over long-term follow-up, LR-3 and especially LR-4 observations have a higher risk for category progression. • Category transitions between sequential exams using different modalities (CT vs. MRI) may reflect modality differences rather than biological change. MRI, especially with the same type of contrast agent, may provide the most reproducible categorization, although this needs additional validation. • In a clinical practice setting, in which radiologists refer to prior imaging and reports, there was no significant association between changes in radiologist and changes in LI-RADS categorization.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Neoplasias Hepáticas/diagnóstico , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada Multidetectores/métodos , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos
18.
J Magn Reson Imaging ; 50(4): 1092-1102, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30701611

RESUMO

BACKGROUND: Quantitative-chemical-shift-encoded (CSE)-MRI methods have been applied to the liver. The feasibility and potential utility CSE-MRI in monitoring changes in pancreatic proton density fat fraction (PDFF) have not yet been demonstrated. PURPOSE: To use quantitative CSE-MRI to estimate pancreatic fat changes during a weight-loss program in adults with severe obesity and nonalcoholic fatty liver disease (NAFLD). To explore the relationship of reduction in pancreatic PDFF with reductions in anthropometric indices. STUDY TYPE: Prospective/longitudinal. POPULATION: Nine adults with severe obesity and NAFLD enrolled in a weight-loss program. FIELD STRENGTH/SEQUENCE: CSE-MRI fat quantification techniques and multistation-volumetric fat/water separation techniques were performed at 3 T. ASSESSMENT: PDFF values were recorded from parametric maps colocalized across timepoints. STATISTICAL TESTS: Rates of change of log-transformed variables across time were determined (linear-regression), and their significance assessed compared with no change (Wilcoxon test). Rates of change were correlated pairwise (Spearman's correlation). RESULTS: Mean pancreatic PDFF decreased by 5.7% (range 0.7-17.7%) from 14.3 to 8.6%, hepatic PDFF by 11.4% (2.6-22.0%) from 14.8 to 3.4%, weight by 30.9 kg (17.3-64.2 kg) from 119.0 to 88.1 kg, body mass index by 11.0 kg/m2 (6.3-19.1 kg/m2 ) from 44.1 to 32.9 kg/m2 , waist circumference (WC) by 25.2 cm (4.0-41.0 cm) from 133.1 to 107.9 cm, HC by 23.5 cm (4.5-47.0 cm) from 135.8 to 112.3 cm, visceral adipose tissue (VAT) by 2.9 L (1.7-5.7 L) from 7.1 to 4.2 L, subcutaneous adipose tissue (SCAT) by 4.0 L (2.9-7.4 L) from 15.0 to 11.0 L. Log-transformed rate of change for pancreatic PDFF was moderately correlated with log-transformed rates for hepatic PDFF, VAT, SCAT, and WC (ρ = 0.5, 0.47, 0.45, and 0.48, respectively), although not statistically significant. DATA CONCLUSION: Changes in pancreatic PDFF can be estimated by quantitative CSE-MRI in adults undergoing a weight-loss surgery program. Pancreatic and hepatic PDFF and anthropometric indices decreased significantly. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019;50:1092-1102.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Cirurgia Bariátrica , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Obesidade Mórbida/cirurgia , Pâncreas/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/diagnóstico por imagem , Projetos Piloto , Estudos Prospectivos , Programas de Redução de Peso
19.
Radiol Imaging Cancer ; 1(2): e190010, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-33778680

RESUMO

Purpose: To describe a single-center preliminary experience with gadoxetate disodium-enhanced abbreviated MRI for hepatocellular carcinoma (HCC) screening and surveillance in patients with cirrhosis or chronic hepatitis B virus (cHBV). Materials and Methods: This was a retrospective study of consecutive patients aged 18 years and older with cirrhosis or cHBV who underwent at least one gadoxetate-enhanced abbreviated MRI examination for HCC surveillance from 2014 through 2016. Examinations were interpreted prospectively by one of six abdominal radiologists for clinical care. Clinical, imaging, and other data were extracted from electronic medical records. Diagnostic adequacy was assessed in all patients. Diagnostic accuracy was assessed in the subset of patients who could be classified as having HCC or not having HCC on the basis of a composite reference standard. Results: In this study, 330 patients (93% with cirrhosis; 45% women; mean age, 59 years) underwent gadoxetate-enhanced abbreviated MRI. In the 330 patients, 311 (94.2%) baseline gadoxetate-enhanced abbreviated MRI examinations were diagnostically adequate. Of 141 (43%) of the 330 patients, 91.4% (129 of 141) could be classified as not having HCC and 8.6% (12 of 141) could be classified as having HCC. Baseline gadoxetate-enhanced abbreviated MRI had 0.92 sensitivity (95% confidence interval [CI]: 0.62, 1.00) and 0.91 specificity (95% CI: 0.84, 0.95) for detection of HCC. Of the 330 patients who underwent baseline gadoxetate-enhanced abbreviated MRI, 187 (57%) were lost to follow-up. Conclusion: Gadoxetate-enhanced abbreviated MRI is feasible clinically, has a high diagnostic adequacy rate, and, on the basis of our preliminary experience, accurately depicts HCC in high-risk patients. Strategies to enhance follow-up compliance are needed.© RSNA, 2019Keywords: Abdomen/GI, Cirrhosis, Liver, MR-Imaging, Oncology, ScreeningSupplemental material is available for this article.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Gadolínio DTPA , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Hepatite B Crônica/diagnóstico por imagem , Humanos , Aumento da Imagem/métodos , Cirrose Hepática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Dados Preliminares , Padrões de Referência , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
J Magn Reson Imaging ; 49(1): 229-238, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29707848

RESUMO

BACKGROUND: Improving the signal-to-noise ratio (SNR) of chemical-shift-encoded MRI acquisition with complex reconstruction (MRI-C) may improve the accuracy and precision of noninvasive proton density fat fraction (PDFF) quantification in patients with hepatic steatosis. PURPOSE: To assess the accuracy of high SNR (Hi-SNR) MRI-C versus standard MRI-C acquisition to estimate hepatic PDFF in adult and pediatric nonalcoholic fatty liver disease (NAFLD) using an MR spectroscopy (MRS) sequence as the reference standard. STUDY TYPE: Prospective. POPULATION/SUBJECTS: In all, 231 adult and pediatric patients with known or suspected NAFLD. FIELD STRENGTH/SEQUENCE: PDFF estimated at 3T by three MR techniques: standard MRI-C; a Hi-SNR MRI-C variant with increased slice thickness, decreased matrix size, and no parallel imaging; and MRS (reference standard). ASSESSMENT: MRI-PDFF was measured by image analysts using a region of interest coregistered with the MRS-PDFF voxel. STATISTICAL TESTS: Linear regression analyses were used to assess accuracy and precision of MRI-estimated PDFF for MRS-PDFF as a function of MRI-PDFF using the standard and Hi-SNR MRI-C for all patients and for patients with MRS-PDFF <10%. RESULTS: In all, 271 exams from 231 patients were included (mean MRS-PDFF: 12.6% [SD: 10.4]; range: 0.9-41.9). High agreement between MRI-PDFF and MRS-PDFF was demonstrated across the overall range of PDFF, with a regression slope of 1.035 for the standard MRI-C and 1.008 for Hi-SNR MRI-C. Hi-SNR MRI-C, compared to standard MRI-C, provided small but statistically significant improvements in the slope (respectively, 1.008 vs. 1.035, P = 0.004) and mean bias (0.412 vs. 0.673, P < 0.0001) overall. In the low-fat patients only, Hi-SNR MRI-C provided improvements in the slope (1.058 vs. 1.190, P = 0.002), mean bias (0.168 vs. 0.368, P = 0.007), intercept (-0.153 vs. -0.796, P < 0.0001), and borderline improvement in the R2 (0.888 vs. 0.813, P = 0.01). DATA CONCLUSION: Compared to standard MRI-C, Hi-SNR MRI-C provides slightly higher MRI-PDFF estimation accuracy across the overall range of PDFF and improves both accuracy and precision in the low PDFF range. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:229-238.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Constrição Patológica/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Razão Sinal-Ruído , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Prótons , Padrões de Referência , Análise de Regressão , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...