1.
Hong Kong Med J ; 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39049143

RESUMO

INTRODUCTION: This study reviewed the diagnostic accuracy of the prehospital electrocardiogram (PHECG) rule-based algorithm for ST-elevation myocardial infarction (STEMI) universally utilised in Hong Kong. METHODS: This prospective observational study was linked to a population-wide project. We analysed 2210 PHECGs performed on patients who presented to the emergency medical service (EMS) with chest pain from 1 October to 31 December 2021. The diagnostic accuracy of the adopted rulebased algorithm, the Hannover Electrocardiogram System, was evaluated using the adjudicated blinded rating by two investigators as the primary reference standard. Diagnostic accuracy was also evaluated using the attending emergency physician's diagnosis and the diagnosis on hospital discharge as secondary reference standards. RESULTS: The prevalence of STEMI was 5.1% (95% confidence interval [CI]=4.2%-6.1%). Using the adjudicated blinded rating by investigators as the reference standard, the rule-based PHECG algorithm had a sensitivity of 94.6% (95% CI=88.2%-97.8%), specificity of 87.9% (95% CI=86.4%-89.2%), positive predictive value of 29.4% (95% CI=24.8%-34.4%), and negative predictive value of 99.7% (95% CI=99.3%-99.9%) [all P<0.05]. CONCLUSION: The rule-based PHECG algorithm that is widely used in Hong Kong demonstrated high sensitivity and fair specificity for the diagnosis of STEMI.