Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Med Genomics ; 15(1): 43, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-35246132

RESUMO

BACKGROUND: The application of long-read sequencing using the Oxford Nanopore Technologies (ONT) MinION sequencer is getting more diverse in the medical field. Having a high sequencing error of ONT and limited throughput from a single MinION flowcell, however, limits its applicability for accurate variant detection. Medical exome sequencing (MES) targets clinically significant exon regions, allowing rapid and comprehensive screening of pathogenic variants. By applying MES with MinION sequencing, the technology can achieve a more uniform capture of the target regions, shorter turnaround time, and lower sequencing cost per sample. METHOD: We introduced a cost-effective optimized workflow, ECNano, comprising a wet-lab protocol and bioinformatics analysis, for accurate variant detection at 4800 clinically important genes and regions using a single MinION flowcell. The ECNano wet-lab protocol was optimized to perform long-read target enrichment and ONT library preparation to stably generate high-quality MES data with adequate coverage. The subsequent variant-calling workflow, Clair-ensemble, adopted a fast RNN-based variant caller, Clair, and was optimized for target enrichment data. To evaluate its performance and practicality, ECNano was tested on both reference DNA samples and patient samples. RESULTS: ECNano achieved deep on-target depth of coverage (DoC) at average > 100× and > 98% uniformity using one MinION flowcell. For accurate ONT variant calling, the generated reads sufficiently covered 98.9% of pathogenic positions listed in ClinVar, with 98.96% having at least 30× DoC. ECNano obtained an average read length of 1000 bp. The long reads of ECNano also covered the adjacent splice sites well, with 98.5% of positions having ≥ 30× DoC. Clair-ensemble achieved > 99% recall and accuracy for SNV calling. The whole workflow from wet-lab protocol to variant detection was completed within three days. CONCLUSION: We presented ECNano, an out-of-the-box workflow comprising (1) a wet-lab protocol for ONT target enrichment sequencing and (2) a downstream variant detection workflow, Clair-ensemble. The workflow is cost-effective, with a short turnaround time for high accuracy variant calling in 4800 clinically significant genes and regions using a single MinION flowcell. The long-read exon captured data has potential for further development, promoting the application of long-read sequencing in personalized disease treatment and risk prediction.


Assuntos
Sequenciamento de Nucleotídeos em Larga Escala , Nanoporos , Análise Custo-Benefício , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Análise de Sequência de DNA/métodos , Fluxo de Trabalho
2.
Sci Rep ; 12(1): 4519, 2022 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-35296758

RESUMO

Structural variation (SV) is a major cause of genetic disorders. In this paper, we show that low-depth (specifically, 4×) whole-genome sequencing using a single Oxford Nanopore MinION flow cell suffices to support sensitive detection of SV, particularly pathogenic SV for supporting clinical diagnosis. When using 4× ONT WGS data, existing SV calling software often fails to detect pathogenic SV, especially in the form of long deletion, terminal deletion, duplication, and unbalanced translocation. Our new SV calling software SENSV can achieve high sensitivity for all types of SV and a breakpoint precision typically ± 100 bp; both features are important for clinical concerns. The improvement achieved by SENSV stems from several new algorithms. We evaluated SENSV and other software using both real and simulated data. The former was based on 24 patient samples, each diagnosed with a genetic disorder. SENSV found the pathogenic SV in 22 out of 24 cases (all heterozygous, size from hundreds of kbp to a few Mbp), reporting breakpoints within 100 bp of the true answers. On the other hand, no existing software can detect the pathogenic SV in more than 10 out of 24 cases, even when the breakpoint requirement is relaxed to ± 2000 bp.


Assuntos
Nanoporos , Algoritmos , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Análise de Sequência de DNA , Software , Translocação Genética , Sequenciamento Completo do Genoma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...