Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 69(12)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38821109

RESUMO

Objective.The validation of deformable image registration (DIR) for contour propagation is often done using contour-based metrics. Meanwhile, dose accumulation requires evaluation of voxel mapping accuracy, which might not be accurately represented by contour-based metrics. By fabricating a deformable anthropomorphic pelvis phantom, we aim to (1) quantify the voxel mapping accuracy for various deformation scenarios, in high- and low-contrast regions, and (2) identify any correlation between dice similarity coefficient (DSC), a commonly used contour-based metric, and the voxel mapping accuracy for each organ.Approach. Four organs, i.e. pelvic bone, prostate, bladder and rectum (PBR), were 3D printed using PLA and a Polyjet digital material, and assembled. The latter three were implanted with glass bead and CT markers within or on their surfaces. Four deformation scenarios were simulated by varying the bladder and rectum volumes. For each scenario, nine DIRs with different parameters were performed on RayStation v10B. The voxel mapping accuracy was quantified by finding the discrepancy between true and mapped marker positions, termed the target registration error (TRE). Pearson correlation test was done between the DSC and mean TRE for each organ.Main results. For the first time, we fabricated a deformable phantom purely from 3D printing, which successfully reproduced realistic anatomical deformations. Overall, the voxel mapping accuracy dropped with increasing deformation magnitude, but improved when more organs were used to guide the DIR or limit the registration region. DSC was found to be a good indicator of voxel mapping accuracy for prostate and rectum, but a comparatively poorer one for bladder. DSC > 0.85/0.90 was established as the threshold of mean TRE ⩽ 0.3 cm for rectum/prostate. For bladder, extra metrics in addition to DSC should be considered.Significance. This work presented a 3D printed phantom, which enabled quantification of voxel mapping accuracy and evaluation of correlation between DSC and voxel mapping accuracy.


Assuntos
Pelve , Imagens de Fantasmas , Humanos , Pelve/diagnóstico por imagem , Doses de Radiação , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Masculino , Impressão Tridimensional
2.
J Appl Clin Med Phys ; 25(7): e14348, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38561975

RESUMO

INTRODUCTION: Daily quality assurance is an integral part of a radiotherapy workflow to ensure the dose is delivered safely and accurately to the patient. It is performed before the first treatment of the day and needs to be time and cost efficient for a multiple gantries proton center. In this study, we introduced an efficient method to perform QA for output constancy, range verification, spot positioning accuracy and imaging and proton beam isocenter coincidence with DailyQA3. METHODS: A stepped acrylic block of specific dimensions is fabricated and placed on top of the DailyQA3 device. Treatment plans comprising of two different spread-out Bragg peaks and five individual spots of 1.0 MU each are designed to be delivered to the device. A mathematical framework to measure the 2D distance between the detectors and individual spot is introduced and play an important role in realizing the spot positioning and centering QA. Lastly, a 5 months trends of the QA for two gantries are presented. RESULTS: The outputs are monitored by two ion chambers in the DailyQA3 and a tolerance of ± 3 % $ \pm 3\% $ are used. The range of the SOBPs are monitored by the ratio of ion chamber signals and a tolerance of ± 1 mm $ \pm 1\ {\mathrm{mm}}$ is used. Four diodes at ± 10 cm $ \pm 10\ {\mathrm{cm}}$ from the central ion chambers are used for spot positioning QA, while the central ion chamber is used for imaging and proton beam isocenter coincidence QA. Using the framework, we determined the absolute signal threshold corresponding to the offset tolerance between the individual proton spot and the detector. A 1.5 mm $1.5\ {\mathrm{mm}}$ tolerances are used for both the positioning and centering QA. No violation of the tolerances is observed in the 5 months trends for both gantries. CONCLUSION: With the proposed approach, we can perform four QA items in the TG224 within 10 min.


Assuntos
Terapia com Prótons , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Terapia com Prótons/métodos , Terapia com Prótons/normas , Humanos , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Neoplasias/radioterapia , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/normas , Imagens de Fantasmas , Algoritmos , Radiometria/métodos
3.
Phys Imaging Radiat Oncol ; 29: 100552, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38405428

RESUMO

Background and purpose: High-density dental fillings pose a non-negligible impact on head and neck cancer treatment. For proton therapy, stopping power ratio (SPR) prediction will be significantly impaired by the associated image artifacts. Dose perturbation is also inevitable, compromising the treatment plan quality. While plenty of work has been done on metal or amalgam fillings, none has touched on composite resin (CR) and glass ionomer cement (GIC) which have seen an increasing usage. Hence, this work aims to provide a detailed characterisation of SPR and dose perturbation in proton therapy caused by CR and GIC. Materials and methods: Four types of fillings were used: CR, Fuji Bulk (FB), Fuji II (FII) and Fuji IX (FIX). The latter three belong to GIC category. Measured SPR were compared with SPR predicted using single-energy computed tomography (SECT) and dual-energy computed tomography (DECT). Dose perturbation of proton beams with lower- and higher-energy levels was also quantified using Gafchromic films. Results: The measured SPR for CR, FB, FII and FIX were 1.68, 1.77, 1.77 and 1.76, respectively. Overall, DECT could predict SPR better than SECT. The lowest percentage error achieved by DECT was 19.7 %, demonstrating the challenge in estimating SPR, even for fillings with relatively lower densities. For both proton beam energies and all four fillings of about 4.5 mm thickness, the maximum dose perturbation was 3 %. Conclusion: This study showed that dose perturbation by CR and GIC was comparatively small. We have measured and recommended the SPR values for overriding the fillings in TPS.

4.
J Appl Clin Med Phys ; 25(2): e14154, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37683120

RESUMO

BACKGROUND: Tolerance limit is defined on pre-treatment patient specific quality assurance results to identify "out of the norm" dose discrepancy in plan. An out-of-tolerance plan during measurement can often cause treatment delays especially if replanning is required. In this study, we aim to develop an outlier detection model to identify out-of-tolerance plan early during treatment planning phase to mitigate the above-mentioned risks. METHODS: Patient-specific quality assurance results with portal dosimetry for stereotactic body radiotherapy measured between January 2020 and December 2021 were used in this study. Data were divided into thorax and pelvis sites and gamma passing rates were recorded using 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria. Statistical process control method was used to determine six different site and criterion-specific tolerance and action limits. Using only the inliers identified with our determined tolerance limits, we trained three different outlier detection models using the plan complexity metrics extracted from each treatment field-robust covariance, isolation forest, and one class support vector machine. The hyperparameters were optimized using the F1-score calculated from both the inliers and validation outliers' data. RESULTS: 308 pelvis and 200 thorax fields were used in this study. The tolerance (action) limits for 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria in the pelvis site are 99.1% (98.1%), 95.8% (91.1%), and 91.7% (86.1%), respectively. The tolerance (action) limits in the thorax site are 99.0% (98.7%), 97.0% (96.2%), and 91.5% (87.2%). One class support vector machine performs the best among all the algorithms. The best performing model in the thorax (pelvis) site achieves a precision of 0.56 (0.54), recall of 1.0 (1.0), and F1-score of 0.72 (0.70) when using the 2%/2 mm (2%/1 mm) criterion. CONCLUSION: The model will help the planner to identify an out-of-tolerance plan early so that they can refine the plan further during the planning stage without risking late discovery during measurement.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Algoritmos , Pelve , Radiometria/métodos , Radioterapia de Intensidade Modulada/métodos , Garantia da Qualidade dos Cuidados de Saúde
5.
Phys Med Biol ; 68(15)2023 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-37437590

RESUMO

Objective. Automatic deformable image registration (DIR) is a critical step in adaptive radiotherapy. Manually delineated organs-at-risk (OARs) contours on planning CT (pCT) scans are deformably registered onto daily cone-beam CT (CBCT) scans for delivered dose accumulation. However, evaluation of registered contours requires human assessment, which is time-consuming and subjects to high inter-observer variability. This work proposes a deep learning model that allows accurate prediction of Dice similarity coefficients (DSC) of registered contours in prostate radiotherapy.Approach. Our dataset comprises 20 prostate cancer patients with 37-39 daily CBCT scans each. The pCT scans and planning contours were deformably registered to each corresponding CBCT scan to generate virtual CT (vCT) scans and registered contours. The DSC score, which is a common contour-based validation metric for registration quality, between the registered and manual contours were computed. A Siamese neural network was trained on the vCT-CBCT image pairs to predict DSC. To assess the performance of the model, the root mean squared error (RMSE) between the actual and predicted DSC were computed.Main results. The model showed promising results for predicting DSC, giving RMSE of 0.070, 0.079 and 0.118 for rectum, prostate, and bladder respectively on the holdout test set. Clinically, a low RMSE implies that the predicted DSC can be reliably used to determine if further DIR assessment from physicians is required. Considering the event where a registered contour is classified as poor if its DSC is below 0.6 and good otherwise, the model achieves an accuracy of 92% for the rectum. A sensitivity of 0.97 suggests that the model can correctly identify 97% of poorly registered contours, allowing manual assessment of DIR to be triggered.Significance. We propose a neural network capable of accurately predicting DSC of deformably registered OAR contours, which can be used to evaluate eligibility for plan adaptation.


Assuntos
Neoplasias de Cabeça e Pescoço , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
6.
Phys Med ; 105: 102513, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36565555

RESUMO

This paper aims to review on fetal dose in radiotherapy and extends and updates on a previous work1 to include proton therapy. Out-of-field doses, which are the doses received by regions outside of the treatment field, are unavoidable regardless of the treatment modalities used during radiotherapy. In the case of pregnant patients, fetal dose is a major concern as it has long been recognized that fetuses exposed to radiation have a higher probability of suffering from adverse effects such as anatomical malformations and even fetal death, especially when the 0.1Gy threshold is exceeded. In spite of the low occurrence of cancer during pregnancy, the radiotherapy team should be equipped with the necessary knowledge to deal with fetal dose. This is crucial so as to ensure that the fetus is adequately protected while not compromising the patient treatment outcomes. In this review paper, various aspects of fetal dose will be discussed ranging from biological, clinical to the physics aspects. Other than fetal dose resulting from conventional photon therapy, this paper will also extend the discussion to modern treatment modalities and techniques, namely proton therapy and image-guided radiotherapy, all of which have seen a significant increase in use in current radiotherapy. This review is expected to provide readers with a comprehensive understanding of fetal dose in radiotherapy, and to be fully aware of the steps to be taken in providing radiotherapy for pregnant patients.


Assuntos
Feto , Complicações Neoplásicas na Gravidez , Dosagem Radioterapêutica , Feminino , Humanos , Gravidez , Feto/efeitos da radiação , Terapia com Prótons/efeitos adversos , Complicações Neoplásicas na Gravidez/radioterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...