Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Biomech (Bristol, Avon) ; 42: 115-119, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28157619

RESUMO

BACKGROUND: Multiple factors contribute to range of motion of the hip joint in the transverse plane: bony anatomy, hip capsule, corresponding ligaments, articular labrum, ligamentum teres, and negative intra-articular pressure. We hypothesized that violation of the negative pressure of the hip and simulation of an effusion would increase range of motion in the transverse plane in a cadaver model. METHODS: Ten hip specimens were obtained and dissected with the femur and iliac wing mounted in a custom joint-testing rig in neutral position. Specimens were tested at 0 and at 90° of flexion with 1.5Nm internal and external rotational torque. Three conditions were assessed: (1) intact specimen, (2) an effusion modeled by a 10ml saline infusion, and (3) a capsular tear. FINDINGS: The modeled effusion decreased rotational range of motion limits in both 0 and 90° of flexion, with a greater effect on the specimens at 0° flexion in external rotation with 4.1° less external rotation (p=0.009). A modeled capsular tear increased rotational motion limits in 0° of flexion in both internal and external rotation and in 90° flexion in internal rotation only (p<0.025). INTERPRETATION: An effusion may decrease the rotation of the hip, and a capsular tear may increase its rotation. This should be considered in hips with traumatic capsular tears or arthroscopic portals.


Assuntos
Articulação do Quadril/fisiopatologia , Hidrartrose/fisiopatologia , Cápsula Articular/lesões , Amplitude de Movimento Articular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Feminino , Fêmur , Lesões do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Humanos , Cápsula Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Modelos Biológicos
2.
J Arthroplasty ; 30(2): 296-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25288524

RESUMO

Balancing a varus knee is traditionally accomplished by releasing the medial soft-tissue sleeve off the tibia. Recently, "pie-crusting" (PC) medial structures has been described. In a biomechanical cadaver study we compared PC to traditional release (TR) to determine their effects on flexion and extension gaps. PC was done in five specimens along the anterior half of the medial soft-tissue sleeve and five along the posterior half, followed by a traditional release. In 90° flexion, valgus laxity after TR was significantly greater than after PC alone. PC of the anterior or posterior aspect of the medial soft-tissue sleeve can effect changes more in flexion than in extension, respectively. Complete TR did not provide more gap opening than PC in extension, but produced more effect in flexion.


Assuntos
Artroplastia do Joelho/métodos , Anteversão Óssea/cirurgia , Articulação do Joelho/cirurgia , Joelho/cirurgia , Osteoartrite do Joelho/fisiopatologia , Tíbia/cirurgia , Fenômenos Biomecânicos , Anteversão Óssea/fisiopatologia , Cadáver , Humanos , Instabilidade Articular/prevenção & controle , Joelho/fisiopatologia , Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Tíbia/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...