Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Infant Behav Dev ; 68: 101746, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35809531

RESUMO

BACKGROUND: Parent-infant interactions provide the foundation for the development of infant socioemotional wellbeing. Preterm birth can have a substantial, and often detrimental, impact on the quality of early parent-infant interactions. Sensory processing difficulties, common in preterm infants, are further associated with poorer interaction quality. There is a paucity of research, however, examining the links between the quality of parent-infant interaction, preterm birth, and sensory processing difficulties. This study aimed to characterise the quality of interactions of parent-infant dyads involving preterm infants who may display sensory processing differences and examine the associations between parent-infant interaction quality, preterm status and infant sensory processing. METHOD: 67 parent-infant dyads (12-months infant age, 22 preterm, 45 full-term) participated in a recorded, semi-structured 15-minute play interaction. Parents also filled out questionnaires on demographics, and infant sensory processing (Infant and Toddler Sensory Profile-2; ITSP-2). Interaction quality was rated using the Parenting Interactions with Children: Checklist of Observations Linked to Outcomes (PICCOLO). RESULTS: Preterm and full-term infants differed in sensory processing and parent-infant interaction. Infant prematurity was associated with the sensory domains of; visual (r = - 0.37, p = .005), touch (r = - 0.39, p = .002), and movement (rs = - .32, p = .01), as well as the interaction domains of; responsivity (rs;= - .43, p = .001), teaching (rs = - .31, p = .02), and interaction total score (r = - 0.34, p = .01). Interaction quality was related to sensory registration (rs = - .38, p = .008), auditory (rs = - .34, p = .02), seeking (rs = .29, p = .05) and sensory behavioural scores (rs = - .52, p < .001). Overall, interaction quality was best predicted by infant prematurity and auditory scores, R2 = .15, F(1, 47) = 4.01, p = .02. DISCUSSION: Preterm infants differed from their full-term peers in both their sensory processing and in their dyadic interactions with parents. Preterm status was associated with less responsivity and teaching and was found to predict overall interaction quality. Poorer infant sensory processing was associated with less parental teaching, affection and responsivity during interactions. Our results suggest that preterm birth is related to sensory processing difficulties, and that prematurity and sensory processing are differentially associated with aspects of interaction quality. These findings support the further examination of the interplay between preterm birth, sensory processing, and parent-infant interaction quality.


Assuntos
Doenças do Prematuro , Relações Mãe-Filho , Nascimento Prematuro , Percepção do Tato , Adulto , Feminino , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro/psicologia , Poder Familiar/psicologia , Pais/psicologia , Percepção , Adulto Jovem
2.
J Clin Microbiol ; 27(4): 716-20, 1989 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2656743

RESUMO

A study was performed to evaluate the UTIscreen (Los Alamos Diagnostics, Los Alamos, N. Mex.), a rapid bioluminescence bacteriuria screen. The UTIscreen was compared with three other rapid bacteriuria screens: the Bac-T-Screen (Vitek Systems, Hazelwood, Mo.), an automated filtration device; the Chemstrip LN (Boehringer Mannheim Diagnostics, BioDynamics, Indianapolis, Ind.), an enzyme dipstick; and the Gram stain. A semiquantitative plate culture was used as the reference method. Of the 1,000 specimens tested, 276 had colony counts of greater than 10(5) CFU/ml by the culture method. Of these, the UTIscreen detected 96% (265 of 276) using greater than or equal to 5% of the integrated light output of the standard reading as a positive interpretive breakpoint, the Bac-T-Screen detected 96% (266 of 276), the Chemstrip LN detected 90% (249 of 276), and the Gram stain detected 96% (264 of 276). Of the 214 probable pathogens isolated at greater than 10(5) CFU/ml, the UTIscreen detected 95% (204 of 214), the Bac-T-Screen detected 98% (210 of 214), the Chemstrip LN detected 92% (198 of 214), and the Gram stain detected 98% (209 of 214). The predictive values of negative test results at greater than 10(5) CFU/ml for the UTIscreen, the Bac-T-Screen, the Chemstrip LN, and the Gram stain were 98, 97, 93, and 98%, respectively. The overall specificities at greater than 10(5) CFU/ml for the UTIscreen, the Bac-T-Screen, the Chemstrip LN, and the Gram stain were 70, 48, 51, and 69%, respectively. There were 532 specimens with colony counts of >10(3) CFU/ml, and of these, the UTIscreen, the Bac-T-Screen, the Chemstrip LN, and the Gram stain detected 72, 81, 76, and 73%, respectively. Of the 249 probable pathogens isolated at >10(3) CFU/ml, the UTIscreen, the Bac-T-Screen, the Chemstrip LN, and the Gram stain detected 91, 95, 89, and 93%, respectively. The overall specificities at > 10(3) CFU/ml for these methods were 79, 55, 57, and 78%, respectively. The cost per test for detection was approximately $0.50 for the Chemstrip LN. Overall, the UTIscreen is rapid and easy to perform; its sensitivity compared favorably with those of the other screening methods; it had higher specificity than the Bac-T-Screen and Chemstrip LN; and it allowed for bathing of specimen.


Assuntos
Bactérias/isolamento & purificação , Medições Luminescentes , Urina/microbiologia , Técnicas Bacteriológicas , Bacteriúria/diagnóstico , Custos e Análise de Custo , Humanos , Valor Preditivo dos Testes , Kit de Reagentes para Diagnóstico , Fitas Reagentes , Fatores de Tempo
3.
Am J Clin Pathol ; 90(1): 87-91, 1988 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3389348

RESUMO

The API 20S (Analytab Products, Plainview, NY), the GPI card (Vitek Systems, St. Louis, MO) and the RapSTR system (Innovative Diagnostics, Atlanta, GA) were compared with conventional biochemicals for the identification of viridans streptococci. One hundred nine clinical isolates were tested that included the following species: intermedius (38) sanguis II (20), bovis (variant) (14), mitis (14), salivarius (11), sanguis I (6), constellatus (3), mutans (2), and uberis (1). With initial testing, a correct species call was made with 72% of the isolates with the GPI card, 62% with the RapSTR, and 50% with the API 20S. Identifications of viridans streptococci group or those that needed additional biochemicals for species identification occurred with 28% of isolates with the API 20S, 8% with the RapSTR, and 9% with the GPI card. Incorrect identifications occurred with 6% of the isolates tested by the GPI card, 20% with the API 20S, and 30% with the RapSTR. Most discrepancies with the RapSTR were with 66% of the intermedius isolates, whereas most, 55%, of misidentifications with the API 20S were with sanguis II isolates. No identifications were made with 2% and 13% of isolates with the API 20S and GPI, respectively.


Assuntos
Kit de Reagentes para Diagnóstico/normas , Streptococcus/classificação , Humanos
4.
Assoc Manage ; 38(2): 86-90, 1986 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10276578
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...