Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pediatr Transplant ; 21(6)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28653457

RESUMO

The purpose of this study was to compare IVIM values in pediatric renal transplants with histopathology and clinical management change. Fifteen pediatric renal transplant recipients (mean 15.7±2.9 years) were prospectively scanned on a 3T MR scanner with multi-b DTI, prior to same-day transplant biopsy. IVIM maps from 14 subjects were analyzed (one excluded due to motion). Mean values were computed from cortical ROIs and medullary ROIs corresponding to the biopsy site. Subjects were also grouped according to whether or not the biopsy resulted in a change in clinical management. Cortico-medullary IVIM estimates and histopathologic Banff scores were correlated with KT. Cortico-medullary IVIM differences between the "change" and "no change" groups was compared with Mann-Whitney U test. Cortical Dp showed significant moderate negative correlation with Banff t and ci scores (KT=-0.497, P=.035 and KT=-0.46, P=.046) and moderate positive correlation with Banff i score (KT=0.527, P=.028). Cortical Pf showed significant moderate correlation with ci and ct scores (KT=0.489, P=.035 and KT=0.457, P=.043). Tissue diffusivity, Dt , estimated with IVIM was significantly different between the "change" and "no change" groups in medullary ROIs (U=6, P=.021). IVIM analysis has potential as a noninvasive biomarker in assessment of pediatric renal allograft pathology.


Assuntos
Imagem de Difusão por Ressonância Magnética , Rejeição de Enxerto/diagnóstico por imagem , Transplante de Rim , Rim/diagnóstico por imagem , Adolescente , Biópsia , Criança , Estudos Transversais , Feminino , Rejeição de Enxerto/patologia , Humanos , Rim/patologia , Masculino , Estudos Prospectivos , Adulto Jovem
2.
AJR Am J Roentgenol ; 208(6): 1358-1364, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28379715

RESUMO

OBJECTIVE: Fractional anisotropy (FA) is a measure of molecular motion obtained from diffusion tensor imaging (DTI). The objective of this study was to assess the use of FA as a noninvasive correlate of renal allograft histopathology. SUBJECTS AND METHODS: Sixteen pediatric renal allograft recipients were imaged using DTI in a prospective study, between October 2014 and January 2016, before a same-day renal allograft biopsy. The Kendall tau correlation coefficient was used to assess the relationship between cortical and medullary FA values and several clinically important Banff renal allograft histopathology scores. The Mann-Whitney U test was also used to compare cortical and medullary FA values in the region of biopsy in patients whose biopsy results did and in those whose biopsy results did not change clinical management. RESULTS: Medullary FA values had direct inverse correlation with several histopathology scores: tubulitis (designated "t" score in Banff pathologic classification, p < 0.04), interstitial inflammation (i score, p < 0.005), tubular atrophy (ct score, p < 0.002), and interstitial fibrosis (ci score, p < 0.007). Cortical FA values inversely correlated with peritubular capillaritis (ptc score, p < 0.02). Neither medullary nor cortical FA values correlated with glomerulitis (g score). At a b value of 800 s/mm2, medullary FA values of pediatric renal allograft recipients whose renal biopsies prompted a change in clinical management (mean ± SD at a b value of 800 s/mm2 = 0.262 ± 0.07; n = 9) were statistically different compared with the group whose biopsy results did not change clinical management (mean ± SD at a b value of 800 s/mm2 = 0.333 ± 0.06; n = 7) (p < 0.006). CONCLUSION: FA is a noninvasive correlate of several important renal allograft histopathology scores and a potential noninvasive method of assessing renal allograft health in pediatric allograft recipients.


Assuntos
Imagem de Tensor de Difusão , Falência Renal Crônica/diagnóstico por imagem , Falência Renal Crônica/terapia , Transplante de Rim , Rim/diagnóstico por imagem , Rim/patologia , Adolescente , Aloenxertos/diagnóstico por imagem , Aloenxertos/patologia , Criança , Feminino , Humanos , Rim/cirurgia , Falência Renal Crônica/patologia , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Resultado do Tratamento , Adulto Jovem
3.
J Magn Reson Imaging ; 46(6): 1590-1600, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28419602

RESUMO

A pedagogical review of fluid-attenuated inversion recovery (FLAIR) and double inversion recovery (DIR) imaging is conducted in this article. The basics of the two pulse sequences are first described, including the details of the inversion preparation and imaging sequences with accompanying mathematical formulae for choosing the inversion time in a variety of scenarios for use on clinical MRI scanners. Magnetization preparation (or T2prep), a strategy for improving image signal-to-noise ratio and contrast and reducing T1 weighting at high field strengths, is also described. Lastly, image artifacts commonly associated with FLAIR and DIR are described with clinical examples, to help avoid misdiagnosis. LEVEL OF EVIDENCE: 5 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1590-1600.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Física , Humanos
4.
Acad Radiol ; 22(3): 370-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25435186

RESUMO

RATIONALE AND OBJECTIVES: To compare the effectiveness of multiacquisition with variable resonance image combination selective (MAVRIC SL) with conventional two-dimensional fast spin-echo (2D-FSE) magnetic resonance (MR) techniques at 3T in imaging patients with a variety of metallic implants. MATERIALS AND METHODS: Twenty-one 3T MR studies were obtained in 19 patients with different types of metal implants. Paired MAVRIC SL and 2D-FSE sequences were reviewed by two radiologists and compared for in-plane and through-plane metal artifact, visualization of the bone implant interface and surrounding soft tissues, blurring, and overall image quality using a two-tailed Wilcoxon signed rank test. The area of artifact on paired images was measured and compared using a paired Wilcoxon signed rank test. Changes in patient management resulting from MAVRIC SL imaging were documented. RESULTS: Significantly less in-plane and through-plane artifact was seen with MAVRIC SL, with improved visualization of the bone-implant interface and surrounding soft tissues, and superior overall image quality (P = .0001). Increased blurring was seen with MAVRIC SL (P = .0016). MAVRIC SL significantly decreased the image artifact compared to 2D-FSE (P = .0001). Inclusion of MAVRIC SL to the imaging protocol determined the need for surgery or type of surgery in five patients and ruled out the need for surgery in 13 patients. In three patients, the area of interest was well seen on both MAVRIC SL and 2D-FSE images, so the addition of MAVRIC had no effect on patient management. CONCLUSIONS: Imaging around metal implants with MAVRIC SL at 3T significantly improved image quality and decreased image artifact compared to conventional 2D-FSE imaging techniques and directly impacted patient management.


Assuntos
Articulação do Quadril/anatomia & histologia , Prótese de Quadril , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Adulto Jovem
5.
Magn Reson Med ; 73(2): 662-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24549782

RESUMO

PURPOSE: Slice encoding for metal artifact correction acquires a three-dimensional image of each excited slice with view-angle tilting to reduce slice and readout direction artifacts respectively, but requires additional imaging time. The purpose of this study was to provide a technique for faster imaging around metallic implants by undersampling k-space. METHODS: Assuming that areas of slice distortion are localized, hexagonal sampling can reduce imaging time by 50% compared with conventional scans. This work demonstrates this technique by comparisons of fully sampled images with undersampled images, either from simulations from fully acquired data or from data actually undersampled during acquisition, in patients and phantoms. Hexagonal sampling is also shown to be compatible with parallel imaging and partial Fourier acquisitions. Image quality was evaluated using a structural similarity (SSIM) index. RESULTS: Images acquired with hexagonal undersampling had no visible difference in artifact suppression from fully sampled images. The SSIM index indicated high similarity to fully sampled images in all cases. CONCLUSION: The study demonstrates the ability to reduce scan time by undersampling without compromising image quality.


Assuntos
Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Prótese Articular , Imageamento por Ressonância Magnética/métodos , Metais , Algoritmos , Interpretação Estatística de Dados , Humanos , Armazenamento e Recuperação da Informação/métodos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
6.
Magn Reson Med ; 69(5): 1268-75, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22711643

RESUMO

Non-contrast-enhanced MR angiography is a promising alternative to the established contrast-enhanced approach as it reduces patient discomfort and examination costs and avoids the risk of nephrogenic systemic fibrosis. Inflow-sensitive slab-selective inversion recovery imaging has been used with great promise, particularly for abdominal applications, but has limited craniocaudal coverage due to inflow time constraints. In this work, a new non-contrast-enhanced MR angiography method using velocity-selective inversion preparation is developed and applied to renal and abdominal angiography. Based on the excitation k-space formalism and Shinnar-Le-Roux transform, a velocity-selective excitation pulse is designed that inverts stationary tissues and venous blood while preserving inferiorly flowing arterial blood. As the magnetization of the arterial blood in the abdominal aorta and iliac arteries is well preserved during the magnetization preparation, artery visualization over a large abdominal field of view is achievable with an inversion delay time that is chosen for optimal background suppression. Healthy volunteer tests demonstrate that the proposed method significantly increases the extent of visible arteries compared with the slab-selective approach, covering renal arteries through iliac arteries over a craniocaudal field of view of 340 mm.


Assuntos
Algoritmos , Aorta Abdominal/anatomia & histologia , Artéria Ilíaca/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Artéria Renal/anatomia & histologia , Abdome/anatomia & histologia , Abdome/irrigação sanguínea , Meios de Contraste , Estudos de Viabilidade , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
J Magn Reson Imaging ; 37(1): 243-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22791572

RESUMO

PURPOSE: To apply compressed sensing (CS) to in vivo multispectral imaging (MSI), which uses additional encoding to avoid magnetic resonance imaging (MRI) artifacts near metal, and demonstrate the feasibility of CS-MSI in postoperative spinal imaging. MATERIALS AND METHODS: Thirteen subjects referred for spinal MRI were examined using T2-weighted MSI. A CS undersampling factor was first determined using a structural similarity index as a metric for image quality. Next, these fully sampled datasets were retrospectively undersampled using a variable-density random sampling scheme and reconstructed using an iterative soft-thresholding method. The fully and undersampled images were compared using a 5-point scale. Prospectively undersampled CS-MSI data were also acquired from two subjects to ensure that the prospective random sampling did not affect the image quality. RESULTS: A two-fold outer reduction factor was deemed feasible for the spinal datasets. CS-MSI images were shown to be equivalent or better than the original MSI images in all categories: nerve visualization: P = 0.00018; image artifact: P = 0.00031; image quality: P = 0.0030. No alteration of image quality and T2 contrast was observed from prospectively undersampled CS-MSI. CONCLUSION: This study shows that the inherently sparse nature of MSI data allows modest undersampling followed by CS reconstruction with no loss of diagnostic quality.


Assuntos
Diagnóstico por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Coluna Vertebral/patologia , Algoritmos , Artefatos , Compressão de Dados/métodos , Análise de Fourier , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador , Modelos Estatísticos , Distribuição Normal , Período Pós-Operatório , Estudos Retrospectivos
8.
Magn Reson Med ; 70(2): 527-36, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23172805

RESUMO

Noncontrast-enhanced renal angiography techniques based on balanced steady-state free precession avoid external contrast agents, take advantage of high inherent blood signal from the T 2 / T 1 contrast mechanism, and have short steady-state free precession acquisition times. However, background suppression is limited; inflow times are inflexible; labeling region is difficult to define when tagging arterial flow; and scan times are long. To overcome these limitations, we propose the use of multiple inversion recovery preparatory pulses combined with alternating pulse repetition time balanced steady-state free precession to produce renal angiograms. Multiple inversion recovery uses selective spatial saturation followed by four nonselective inversion recovery pulses to concurrently null a wide range of background T 1 species while allowing for adjustable inflow times; alternating pulse repetition time steady-state free precession maintains vessel contrast and provides added fat suppression. The high level of suppression enables imaging in three-dimensional as well as projective two-dimensional formats, the latter of which has a scan time as short as one heartbeat. In vivo studies at 1.5 T demonstrate the superior vessel contrast of this technique.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Artéria Renal/anatomia & histologia , Artéria Renal/fisiologia , Circulação Renal/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
9.
Magn Reson Imaging ; 30(2): 158-64, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22055852

RESUMO

A three-dimensional balanced steady-state free precession (b-SSFP)-Dixon technique with a novel group-encoded k-space segmentation scheme called GUINNESS (Group-encoded Ungated Inversion Nulling for Non-contrast Enhancement in the Steady State) was developed. GUINNESS was evaluated for breath-held non-contrast-enhanced MR angiography of the renal arteries on 18 subjects (6 healthy volunteers, 12 patients) at 3.0 T. The method provided high signal-to-noise and contrast renal angiograms with homogeneous fat and background suppression in short breath-holds on the order of 20 s with high spatial resolution and coverage. GUINNESS has potential as a short breath-hold alternative to conventional respiratory-gated methods, which are often suboptimal in pediatric subjects and patients with significant diaphragmatic drift/sleep apnea.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Obstrução da Artéria Renal/patologia , Artéria Renal/patologia , Meios de Contraste , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade
10.
J Magn Reson Imaging ; 35(4): 875-81, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22095672

RESUMO

PURPOSE: To evaluate the capability of a new breathhold non-contrast-enhanced MRA method (Non-contrast Outer Radial Inner Square k-space Scheme, NORISKS) to visualize renal arteries by comparing the method with a routine clinical but significantly longer non-contrast-enhanced (non-CE) MRA technique. MATERIALS AND METHODS: Eighteen subjects referred for abdominal MRI were examined with NORISKS and a routine non-contrast-enhanced MRA technique. Two versions of NORISKS were evaluated: with and without ECG gating. The images were then scored independently and in blinded manner by two radiologists on 5-point scales for visualization of the proximal and distal renal arteries and quality of fat suppression. RESULTS: No statistically significant difference was detected between NORISKS and routine clinical non-CE MRA in all categories except for visualization of the distal renal arteries where ungated NORISKS performed poorer than the routine non-CE MRA (P < 10(-4) ). CONCLUSION: We have demonstrated a promising non-CE MRA method for acquiring renal angiograms within a breathhold without any compromise in spatial resolution or coverage. ECG-gated NORISKS is able to acquire renal angiograms that are comparable to a routine clinical non-CE MRA method (Inhance IFIR, GE Healthcare), which requires approximately seven times the scan time of NORISKS.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Artéria Renal/anatomia & histologia , Mecânica Respiratória , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Adulto Jovem
11.
AJR Am J Roentgenol ; 197(3): 547-55, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21862795

RESUMO

OBJECTIVE: The purpose of this article is to review some of the basic principles of imaging and how metal-induced susceptibility artifacts originate in MR images. We will describe common ways to reduce or modify artifacts using readily available imaging techniques, and we will discuss some advanced methods to correct readout-direction and slice-direction artifacts. CONCLUSION: The presence of metallic implants in MRI can cause substantial image artifacts, including signal loss, failure of fat suppression, geometric distortion, and bright pile-up artifacts. These cause large resonant frequency changes and failure of many MRI mechanisms. Careful parameter and pulse sequence selections can avoid or reduce artifacts, although more advanced imaging methods offer further imaging improvements.


Assuntos
Artefatos , Imageamento por Ressonância Magnética/métodos , Metais , Próteses e Implantes , Humanos , Aumento da Imagem/métodos
12.
Magn Reson Med ; 64(5): 1404-12, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20632411

RESUMO

Variable flip angles are used in steady-state free precession (SSFP) acquisitions (e.g., time-of-flight) but to a lesser extent than in spin echo acquisitions. In balanced steady-state free precession, imaging is often assumed to occur during the steady state, which has been well described in the literature. However, in many cases, imaging occurs during the transient stage, and the use of variable flip angles can improve signal and thus image quality. Here, we present the calculation of flip angles in transient balanced steady-state free precession to generate a predefined signal profile. The signal profile was iteratively optimized to maximize the integral of the signal versus time curve. The key contribution of this work is the formulation of the flip angle as a deterministic function of the preceding and desired magnetization. Catalyzation schemes, e.g., Kaiser-windowed ramp, can be combined with variable flip angles balanced steady-state free precession to reduce signal oscillations. A uniform signal profile was used as an example to demonstrate the variable flip angle algorithm. Accuracy of the algorithm and Bloch simulations were verified with MRI phantom acquisitions. Renal angiograms were acquired using an inflow-based balanced steady-state free precession MR angiography technique; improved small-vessel depiction was observed in volunteer examinations.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Humanos , Angiografia por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...