1.
Rev Sci Instrum ; 82(5): 054703, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21639528

RESUMO

Millimeter wave (MMW) radiometry can be used for simultaneous measurement of emissivity and temperature of materials under extreme environments (high temperature, pressure, and corrosive environments). The state-of-the-art dual channel MMW passive radiometer with active interferometric capabilities at 137 GHz described here allows for radiometric measurements of sample temperature and emissivity up to at least 1600 °C with simultaneous measurement of sample surface dynamics. These capabilities have been used to demonstrate dynamic measurement of melting of powders of simulated lunar regolith and static measurement of emissivity of solid samples. The paper presents the theoretical background and basis for the dual-receiver system, describes the hardware in detail, and demonstrates the data analysis. Post-experiment analysis of emissivity versus temperature allows further extraction from the radiometric data of millimeter wave viewing beam coupling factors, which provide corroboratory evidence to the interferometric data of the process dynamics observed. These results show the promise of the MMW system for extracting quantitative and qualitative process parameters for industrial processes and access to real-time dynamics of materials behavior in extreme environments.

2.
Rev Sci Instrum ; 81(10): 10D910, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033942

RESUMO

A 110/137 GHz radiometer pair with collimated antenna pattern is being used to diagnose optically thin harmonic electron cyclotron emission from hot electrons in LDX. Signal levels of 0.1-1 keV and 110/137 ratios of 2-4 stationary with ECRH power have been observed. The large plasma core magnetic field gradient causes all relevant harmonics to be simultaneously viewed over a angle(k,B) angular range of 0°-90° representing a unique geometry for interpretation of ECE in terms of hot electron temperature and density.

3.
Phys Rev Lett ; 105(13): 135101, 2010 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-21230783

RESUMO

An experimental study of picosecond pulse amplification in a gyrotron-traveling wave tube (gyro-TWT) has been carried out. The gyro-TWT operates with 30 dB of small signal gain near 140 GHz in the HE06 mode of a confocal waveguide. Picosecond pulses show broadening and transit time delay due to two distinct effects: the frequency dependence of the group velocity near cutoff and gain narrowing by the finite gain bandwidth of 1.2 GHz. Experimental results taken over a wide range of parameters show good agreement with a theoretical model in the small signal gain regime. These results show that in order to limit the pulse broadening effect in gyrotron amplifiers, it is crucial to both choose an operating frequency at least several percent above the cutoff of the waveguide circuit and operate at the center of the gain spectrum with sufficient gain bandwidth.


Assuntos
Amplificadores Eletrônicos , Ciclotrons , Processamento de Sinais Assistido por Computador/instrumentação , Micro-Ondas
4.
Int J Infrared Millimeter Waves ; 29(11): 1011-1018, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19081774

RESUMO

We report the measurement of small losses in transmission line (TL) components intended for high-power millimeter-wave applications. Measurements were made using two different low-power techniques: a coherent technique using a vector network analyzer (VNA) and an incoherent technique using a radiometer. The measured loss in a 140 GHz 12.7 mm diameter TL system, consisting of 1.7 m of circular corrugated waveguide and three miter bends, is dominated by the miter bend loss. The measured loss was 0.3±0.1 dB per miter bend using a VNA; and 0.22±0.1 dB per miter bend using a radiometer. Good agreement between the two measurement techniques implies that both are useful for measuring small losses. To verify the methodology, the VNA technique was employed to measure the extremely small transmission loss in a 170 GHz ITER prototype TL system consisting of three lengths of 1 m, 63.5 mm diameter, circular corrugated waveguide and two miter bends. The measured loss of 0.05±0.02 dB per miter bend may be compared with the theoretical loss of 0.027 dB per miter bend. These results suggest that low-power testing of TL losses, utilizing a small, simple TL system and a VNA, is a reliable method for evaluating performance of low-loss millimeter-wave TL components intended for use in high-power applications.