Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiother Oncol ; 152: 8-13, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32738260

RESUMO

PURPOSE: To evaluate usefulness of hyaluronic acid (HA) hydrogel as a tumour bed marker in breast conserving therapy (BCT). To analyze inter- (Inter-OV) and intraobserver (Intra-OV) variability of contouring boost target volume (CTVboost) in external beam radiotherapy (EBRT). MATERIALS AND METHODS: Thirty-two patients in the HA group and 30 patients in the control group with an early stage breast cancer were included in the study. During the surgery 1-3 ml of HA hydrogel was injected into breast to mark the tumour bed for every patient in the HA group. Moreover, surgical clips were placed underneath the lumpectomy cavity. Patients in the control group were marked only by metal markers. Three radiation oncologists delineated CTVboost twice for every patient. Three parameters were calculated to quantify contouring variability: coefficient of variation for volumes (COVV), center of mass displacement (CoMd) and conformity index (CI). RESULTS: There were no significant differences between mean values of COVV for HA and control group, neither for Intra-OV (0.14 vs 0.13) nor Inter-OV (0.19 vs 0.18) calculations. The mean CoMd were 6.1 mm and 9.1 mm for Inter-OV calculations and 3.9 mm and 6.4 mm for Intra-OV in the HA and the control group respectively. The mean CI for Intra-OV improved from 0.61 to 0.65 and from 0.47 to 0.56 for Inter-OV in the control and HA group respectively. CONCLUSION: HA hydrogel used as a tumour bed marker improves tumour bed visibility and reduces inter- and intraobserver variability of EBRT boost target volume delineations.


Assuntos
Neoplasias da Mama/radioterapia , Ácido Hialurônico/administração & dosagem , Hidrogéis/administração & dosagem , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radioterapia/métodos , Instrumentos Cirúrgicos
2.
J Contemp Brachytherapy ; 7(6): 479-84, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26816505

RESUMO

PURPOSE: The purpose of this study is to evaluate our first experience with 3D image-guided breast brachytherapy and to compare dose distribution parameters between Paris dosimetry system (PDS) and image-based plans. MATERIAL AND METHODS: First 49 breast cancer patients treated with 3D high-dose-rate interstitial brachytherapy as a boost were selected for the study. Every patient underwent computed tomography, and the planning target volume (PTV) and organs at risk (OAR) were outlined. Two treatment plans were created for every patient. First, based on a Paris dosimetry system (PDS), and the second one, imaged-based plan with graphical optimization (OPT). The reference isodose in PDS implants was 85%, whereas in OPT plans the isodose was chosen to obtain proper target coverage. Dose and volume parameters (D90, D100, V90, V100), doses at OARs, total reference air kerma (TRAK), and quality assurance parameters: dose nonuniformity ratio (DNR), dose homogeneity index (DHI), and conformity index (COIN) were used for a comparison of both plans. RESULTS: The mean number of catheters was 7 but the mean for 20 first patients was 5 and almost 9 for the next 29 patients. The mean value of prescribed isodose for OPT plans was 73%. The mean D90 was 88.2% and 105.8%, the D100 was 59.8% and 75.7%, the VPTV90 was 88.6% and 98.1%, the VPTV100 was 79.9% and 98.9%, and the TRAK was 0.00375 Gym(-1) and 0.00439 Gym(-1) for the PDS and OPT plans, respectively. The mean DNR was 0.29 and 0.42, the DHI was 0.71 and 0.58, and the COIN was 0.68 and 0.76, respectively. CONCLUSIONS: The target coverage in image-guided plans (OPT) was significantly higher than in PDS plans but the dose homogeneity was worse. Also, the value of TRAK increased because of change of prescribing isodose. The learning curve slightly affected our results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...