Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 29(11): 16665-16675, 2021 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-34154224

RESUMO

We investigate the effect of 2-beam coupling in different imaging geometries in generating intensity-difference squeezing from four-wave mixing (4WM) in Rb atomic vapors. A recently-introduced dual-seeding technique can cancel out the classical noise in a seeded four-wave mixing process. This dual-seeding technique, however, can introduce new complications that involve 2-beam coupling between different seeded spatial modes in the atomic vapor and can ruin squeezing at frequencies on the order of the atomic linewidth and below. This complicates some forms of quantum imaging using these systems. Here we show that seeding the 4WM process with skew rays can eliminate the excess noise caused by 2-beam coupling. To avoid 2-beam coupling in bright, seeded images, it is important to re-image the object in the gain medium, instead of focussing through it.

2.
Opt Express ; 27(4): 4769-4780, 2019 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-30876087

RESUMO

We report the generation of strong, bright-beam intensity-difference squeezing down to measurement frequencies below 10 Hz. We generate two-mode squeezing in a four-wave mixing (4WM) process in Rb vapor, where the single-pass-gain nonlinear process does not require cavity locking and only relies on passive stability. We use diode laser technology and several techniques, including dual seeding, to remove the noise introduced by seeding the 4WM process as well as the background noise. Twin-beam intensity-difference squeezing down to frequencies limited only by the mechanical and atmospheric stability of the lab is achieved. These results should enable important low-frequency applications such as direct intensity-difference imaging with bright beams on integrating detectors.

3.
Phys Rev Lett ; 106(19): 193006, 2011 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-21668152

RESUMO

We report on the first experimental demonstration of low-light-level cross-phase modulation (XPM) with double slow light pulses based on the double electromagnetically induced transparency (EIT) in cold cesium atoms. The double EIT is implemented with two control fields and two weak fields that drive populations prepared in the two doubly spin-polarized states. Group velocity matching can be obtained by tuning the intensity of either of the control fields. The XPM is based on the asymmetric M-type five-level system formed by the two sets of EIT. Enhancement in the XPM by group velocity matching is observed. Our work advances studies of low-light-level nonlinear optics based on double slow light pulses.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...