Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Agric Food Chem ; 72(12): 6638-6650, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38482854

RESUMO

Accurate quantification of mycotoxin in cereals is crucial for ensuring food safety and human health. However, the preparation of traditional multisample external calibration curves (MSCCs) is labor-intensive and error-prone. Here, a multiple isotopologue reaction-monitoring (MIRM)-LC-MS/MS method for accurate quantitation of ten major mycotoxins in cereals was successfully developed and validated, where a novel one-sample multipoint calibration curve (OSCC) strategy is used instead of MSCCs. The OSCC can be established by examining the correlation between the calculated theoretical isotopic abundances and the measured abundance across various MIRM channels. In comparison to the MSCC, the OSCC strategy exhibits outstanding performance including superior selectivity, accuracy (78.4-108.6%), and precision (<12.5%). Furthermore, the proposed OSCC-MIRM-LC-MS/MS method was successfully applied to investigate mycotoxin contamination in cereal samples in China. Considering the advantages of simplified workflows and improved throughput, the OSCC-MIRM-LC-MS/MS methodology holds great promise for accurately quantifying chemical contaminants in foods.


Assuntos
Micotoxinas , Humanos , Micotoxinas/análise , Cromatografia Líquida/métodos , Espectrometria de Massa com Cromatografia Líquida , Grão Comestível/química , Espectrometria de Massas em Tandem/métodos
2.
Food Chem ; 420: 135593, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37080113

RESUMO

Preparing of calibration curves are critical steps for accurate quantitative LC-MS bioanalysis. Traditional multi-sample external calibration curve (MSCC) is labor-intensive and prone to error. In this study, a novel strategy of one sample multi-point calibration curve (OSCC) using multiple isotopologue reaction monitoring (MIRM) was proposed and validated using LC-MS for the quantitation of six aflatoxins in milk and oat-based milk samples. The developed MIRM-OSCC methodology is comprehensively validated and the results indicated that the established method exhibits good performance in selectivity, sensitivity, accuracy and precision. Furthermore, the OSCC could realize sample dilution by monitoring the MIRM channel with less intensity for samples beyond the upper limit of quantification, without the need of sample dilution, which improves the assay throughput. Considering the advantages of excluding the MSCC preparation and sample dilution in OSCC, this strategy can be widely applied in various fields such as drugs, food safety and environmental analysis.


Assuntos
Aflatoxinas , Animais , Cromatografia Líquida/métodos , Aflatoxinas/análise , Leite/química , Avena , Espectrometria de Massas em Tandem/métodos , Calibragem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...