Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Endovasc Ther ; 30(2): 163-175, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35179077

RESUMO

OBJECTIVE: To evaluate the effectiveness and safety of using off-the-shelf "Octopus" technique to treat ruptured or symptomatic thoracoabdominal aortic aneurysm (TAAA) and pararenal abdominal aortic aneurysm (PRAAA). METHODS AND RESULTS: All cases who underwent "Octopus" technique from May 2016 to May 2019 at our center were retrospectively analyzed. A total of 10 cases (8 males) were included. The mean age was 54.5±14.2 years (range: 31-80 years). Eight cases presented as aneurysm rupture or impending rupture accepted emergency repair. Technical success, defined by placement of all endografts as planned, was achieved in all cases. A total of 30 target visceral branches were successfully cannulated, 9 celiac arteries were covered intentionally. Intraoperative endoleak was observed in 6 patients, all of them were gutter leak. During hospital stay, there was no death, no side branch occlusion or spinal cord ischemia. Median follow-up was 30 months (range: 12-50 months). One patient died of lung cancer at 14-month follow-up. There was no secondary endoleak. The primary endoleak were found spontaneously resolved in 3 cases at 7 days, 3-month, and 1-year imaging. One persistent endoleak totally resolved after sealing of gutter spaces at 4-month follow-up. The other 2 persistent endoleak decreased during follow-up, which are still under observation. The branch patency rate was 90.3% (28/31). All the 3 occluded branches were renal arteries. Branch occlusion occurred in 2 cases at 1-month follow-up and 1 case at 2-year follow-up, but renal insufficiency was not observed in these cases. Obvious aneurysm sac shrinkage (≥5 mm) was observed in all cases. The aneurysm size shrunk from 7.6±1.9 to 5.5±1.4 cm. No spinal cord ischemia occurred during follow-up. CONCLUSION: Treatment of ruptured TAAA and PRAAA with "Octopus" technique is feasible and safe for high surgical risk patients in the absence of fenestrated and branched devices. The long-term clinical outcomes needed to be investigated.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Procedimentos Endovasculares , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Prótese Vascular , Implante de Prótese Vascular , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Isquemia/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
2.
Ann Vasc Surg ; 73: 344-350, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33383139

RESUMO

BACKGROUND: One of the ongoing debates about carotid endarterectomy (CEA) is the closure technique of arterial wall in the operation. Current guidelines recommend routine patch closure (PAC); this recommendation is based on the evidence reported 10-20 years ago. Therefore, the exact role of PAC and primary closure (PRC) remains uncertain. The objectives of this study were to compare the perioperative and long-term outcomes of patients who underwent CEA with different closure techniques. METHODS: From January 2013 and December 2018, one senior vascular surgeon performed CEA for 126 patients in the First Affiliated Hospital, Sun Yat-sen University. The closure technique (PAC or PRC) was determined on the characteristics (diameter and level) of carotid arteries. Patient demographics and clinical data were retrospectively collected by two research fellows by reviewing the hospital medical records and relevant radiologic studies, as were carotid duplex reports, indications, intraoperative data, closure technique, and perioperative complications. Data of long-term outcomes were gathered by reviewing outpatient clinic visits and associated supplementary examinations. RESULTS: PRC was performed in 78 operations (61.9%), and PAC was performed in 48 operations (38.1%). There were no statistical differences in demographic and clinical data between the two groups. Carotid clamp time (P < 0.001) and operating time (P < 0.001) were significantly longer when performing PAC (P < 0.001), and intraoperative blood loss was significantly more when performing PAC than that of PRC (P < 0.001). The postoperative outcome and the follow-up results showed that there was no significant difference in the short-term and middle-term overall survival rate and restenosis-free survival rate between the two groups. CONCLUSIONS: There are no differences in postoperative and middle-term outcomes between PAC and selective PRC, whereas PRC technique can save operation time and shorten the intraoperative carotid clamp time. PRC can be safely applied in patients with a greater than 5 mm internal carotid artery (ICA).


Assuntos
Angioplastia/instrumentação , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Idoso , Angioplastia/efeitos adversos , Angioplastia/mortalidade , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , China , Constrição , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
J Ultrasound Med ; 37(12): 2759-2767, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29672890

RESUMO

OBJECTIVES: To evaluate the feasibility of the ultrafast ultrasound pulsed wave velocity (PWV) for carotid stiffness assessment and potential influencing factors. METHODS: Ultrafast PWV measurements of 442 carotid arteries in 162 consecutive patients (patient group) and 66 healthy volunteers (control group) were performed. High- and very high-frequency transducers were used in 110 carotid segments. The ultrafast PWVs at the beginning and end of systole were automatically measured. The correlations between the intima-media thickness (IMT) and ultrafast PWV and the equipment and carotid factors influencing the utility of ultrafast PWV were analyzed. RESULTS: Each ultrafast PWV acquisition was completed within 1 minute. The intraobserver variability showed mean differences ± SD of 0.12 ± 1.28 m/s for the PWV before systole and 0.06 ± 1.30 m/s for the PWV at the end of systole. Ultrafast PWV measurements were more likely obtained with the very high- frequency transducer when the IMT was less than 1.5 mm (P < .05). A generalized linear mixed-effects model analysis showed that the very high-frequency transducer had a greater ability to obtain a valid carotid ultrafast PWV measurement with an IMT of less than 1.5 mm (P < .05). The IMT was positively correlated with the PWV before systole and at the end of systole (r = 0.207-0.771; all P < .05) in the control group, patient group, and carotid subgroup with an IMT of less than 1.5 mm. A multiple regression analysis showed that the IMT and plaque were important independent factors in predicting failure of the ultrafast PWV (P < .001). CONCLUSIONS: The ultrafast PWV is an effective and user-friendly method for evaluating carotid stiffness. The IMT and transducer type are factors influencing the ability to obtain an ultrafast PWV measurement.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Processamento de Imagem Assistida por Computador/métodos , Rigidez Vascular/fisiologia , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Análise de Onda de Pulso , Reprodutibilidade dos Testes , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...