Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 11249, 2024 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755348

RESUMO

This technique-focused observational study explores the impact of a 6-week Nordic Walking (NW) program on physiological and biomechanical aspects in ischemic heart disease (IHD) patients. Twelve male IHD patients (66.2 ± 5.2 years, 12.2 ± 7.5 years of disease duration) were evaluated pre- and post-training for (i) gait parameters, (ii) exercise tolerance using electrocardiographic (ECG) stress test, (iii) a 6-min walk test (6MWT). The NW training, adhering to IHD patient guidelines, involved a 100-m walk at a self-selected, preferred speed without sticks, with classic NW sticks and mechatronic sticks. A mechatronic measuring system, specifically engineered for measuring, diagnosing and monitoring the patient's gait, was integrated into mechatronic sticks. Post-training, significant enhancements were observed in ECG stress test duration, metabolic equivalency, and 6MWT distance, irrespective of the stick type. However, no significant changes were noted in spatiotemporal parameters concerning the measured side, stick utilisation, or type. The results suggest that NW training boosts exercise capacity and refines gait mechanics in male IHD patients. However, the improvement in exercise capacity was not linked to changes in gait mechanics from NW training but rather to the movement during NW gait. Hence, the key to enhancing exercise capacity in IHD patients is the movement during NW gait, not the quality of gait mechanics.


Assuntos
Tolerância ao Exercício , Marcha , Isquemia Miocárdica , Caminhada , Humanos , Masculino , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/reabilitação , Marcha/fisiologia , Idoso , Caminhada/fisiologia , Tolerância ao Exercício/fisiologia , Pessoa de Meia-Idade , Terapia por Exercício/métodos , Eletrocardiografia , Teste de Caminhada , Teste de Esforço
2.
Sensors (Basel) ; 23(20)2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37896529

RESUMO

Marching with Nordic walking (NW) poles is a common form of physical activity. It is recommended in the treatment and rehabilitation of many diseases. NW's wide range of applications in rehabilitation and its effectiveness are limited by the need for experienced physiotherapists to supervise patients during the training. A prerequisite for good rehabilitation results is correctly using the poles during walking. Essential parameters of NW include the angle of inclination of the pole, the force of the pole on the ground, and proper coordination of performed movements. The purpose of this paper is to present the design and operating principle of a mechatronic NW pole system for measuring and recording the gait parameters. The subject of the work was the assessment of the usefulness of the mechatronic NW pole system for phases identified during marching. The study was conducted in field conditions. The study's main objective was to compare the obtained results from the developed system with those of a commercial system for measuring foot pressure distributions on the ground. The paper also presents sample results measuring walkers' gait with NW poles in the field and the resulting gait phase analysis.


Assuntos
Caminhada Nórdica , Consumo de Oxigênio , Humanos , Caminhada , Marcha , Exercício Físico
3.
Appl Bionics Biomech ; 2023: 1135733, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37304836

RESUMO

The study aimed to compare the technique of normal gait with the Nordic walking (NW) gait with classical and mechatronic poles in patients with ischemic heart disease. It was assumed that equipping classical NW poles with sensors enabling biomechanical gait analysis would not cause a change in the gait pattern. The study involved 12 men suffering from ischemic heart disease (age: 66.2 ± 5.2 years, body height: 173.8 ± 6.74 cm; body mass: 87.3 ± 10.89 kg; disease duration: 12.2 ± 7.5 years). The MyoMOTION 3D inertial motion capture system (Noraxon Inc., Scottsdale, AZ, USA) was used to collect biomechanical variables of gait (spatiotemporal and kinematic parameters). The subject's task was to cover the 100 m distance with three types of gait-walking without poles (normal gait), walking with classical poles to NW, and walking with mechatronic poles from the so-called preferred velocity. Parameters were measured on the right and left sides of the body. The data were analyzed using two-way repeated measures analysis of variance with the between-subject factor "body side." Friedman's test was used when necessary. For most kinematic parameters, with the exception of knee flexion-extension (p = 0.474) and shoulder flexion-extension (p = 0.094), significant differences were found between normal and walking with poles for both the left and right side of the body and no differences due to the type of pole. Differences between the left and right movement ranges were identified only for the ankle inversion-eversion parameter (gait without poles p = 0.047; gait with classical poles p = 0.013). In the case of spatiotemporal parameters, a reduction in the cadence step value using mechatronic poles and the stance phase using classical poles compared to normal walking was observed. There was also an increase in the values for step length and step time regardless of the type of poles, stride length, and swing phase when using classical poles and stride time when using mechatronic poles. The differences between the right and left sides of the measurement occurred when walking with both types of poles for single support (gait with classical poles p = 0.003; gait with mechatronic poles p = 0.030), stance phase (gait with classical poles p = 0.028; gait with mechatronic poles p = 0.017) and swing phase (gait with classical poles p = 0.028; gait with mechatronic poles p = 0.017). Mechatronic poles can be used in the study of the biomechanics of gait in real-time with feedback on its regularity because no statistically significant differences were found between the NW gait with classical and mechatronic poles in the studied men with ischemic heart disease.

4.
Artigo em Inglês | MEDLINE | ID: mdl-36612484

RESUMO

This study compared selected temporal and kinematic parameters of normal gait and Nordic Walking (NW) performed with classic and mechatronic poles (classic poles equipped with sensors). It was assumed that equipping NW poles with sensors for biomechanical gait analysis would not impair the NW walking technique. Six professional NW instructors and athletes, including three women, participated in the study. The MyoMotion MR3 motion analysis system was used to collect gait kinematic variables. The subject's task was to cover a 100-m distance with three types of gait: a gait without poles, a gait with classic NW poles, and a gait with mechatronic poles at the preferred speed. Parameters were measured both on the right and left sides of the body. No significant differences were found between gait types for three temporal parameters: step cadence, step, and stride time. For the other variables, all the differences identified were between free-walking and walking with poles, with no differences between standard and mechatronic poles. For nine kinematic parameters, differences between free-walking and walking with poles for both the left and right sides were found, while no differences were due to the pole type. All temporal parameters were characterized by symmetry, while among kinematic parameters, only two were asymmetrical (shoulder abduction-adduction in walking with regular poles and elbow flexion-extension in walking without poles). Equipping classic NW poles with additional signaling and measuring devices (mechatronic poles) does not impair the NW technique, making it possible to use them in further studies of gait biomechanics.


Assuntos
Marcha , Caminhada , Humanos , Feminino , Movimento , Caminhada Nórdica , Análise da Marcha
5.
Sensors (Basel) ; 21(2)2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33430138

RESUMO

This article is devoted to the novel method of upper limb rehabilitation support using a dedicated mechatronic system. The mechatronic rehabilitation system's main advantages are the repeatability of the process and the ability to measure key features and the progress of the therapy. In addition, the assisted therapy standard is the same for each patient. The new method proposed in this article is based on the prediction of the patient's intentions, understood as the intentions to perform a movement that would be not normally possible due to the patient's limited motor functions. Determining those intentions is realized based on a comparative analysis of measured kinematic (range of motion, angular velocities, and accelerations) and dynamic parameter values, as well as external loads resulting from the interaction of patients. Appropriate procedures were implemented in the control system, for which verification was conducted via experiments. The aim of the research in the article was to examine whether it is possible to sense the movement intentions of a patient during exercises, using only measured load parameters and kinematic parameters of the movement. In this study, the construction of a mechatronic system prototype equipped with sensory grip to measure the external loads, control algorithms, and the description of experimental studies were presented. The experimental studies of the mechanism were aimed at the verification of the proper operation of the system and were not a clinical trial.


Assuntos
Intenção , Reabilitação do Acidente Vascular Cerebral , Terapia por Exercício , Humanos , Movimento , Amplitude de Movimento Articular , Extremidade Superior
6.
Clin Biomech (Bristol, Avon) ; 63: 79-84, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30849649

RESUMO

BACKGROUND: The mechanical parameters of the Ilizarov fixator are influenced by many factors related to its spatial configuration. The aim of this study was to experimentally evaluate the impact of the type of implant and the number of distraction rods on the uniformity of loading of distraction rods and stiffness coefficients of the Ilizarov fixator. METHODS: The tests were carried out on a physical model. The model was mounted in a universal loading station MTS 858 Mini Bionix. Forces in distraction rods are measured with the use of strain gauge force transducers. Displacements of bone fragments were measured by means of digital image correction. FINDINGS: In the case of a fixator with 3 distraction rods, configuration of implants has no statistically significant effect on the forces occurring in distraction rods. In the case of a fixator with 4 distraction rods, there are statistically significant differences in the forces in distraction rods. The highest transverse stiffness coefficients occurs in the system with 4 distraction rods and the configuration of 1K1S implants, while the smallest transverse stiffness coefficients occurs in the fixator with 4 distraction rods and the configuration of 0K1S implants. INTERPRETATION: Based on the results of experiments on the physical model, we observed an asymmetry in the distribution of forces transmitted through distraction rods. The configuration with 3 distraction rods provides more uniform distribution of forces in distraction rods and reduces the impact of the implant configuration on transverse stiffness coefficients. The use of a configurations with 4 rods may be advantageous when we want to obtain greater transverse stiffness coefficients of a system consisting of the fixator and fragments of the lengthened bone.


Assuntos
Parafusos Ósseos , Fixadores Externos , Fêmur/fisiologia , Equipamentos Ortopédicos , Fenômenos Biomecânicos , Desenho de Equipamento , Fêmur/anormalidades , Fraturas Ósseas , Humanos , Imageamento Tridimensional , Teste de Materiais , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...