RESUMO
A novel flow injection chemiluminescent enhancement method for the determination of tannic acid based on luminol-KIO4-Mn2+ system is developed. The method is simple, rapid and effective to determine tannic acid in the range of 3.0×10-8~5.0×10-6 mol/L with a detection limit of 9×10-9 mol/L. The relative standard deviation is 1.5% for the determination of 1.0×10-6 mol/L tannic acid (n=11). The mehtod has been applied to determine the content of tannic acid in Chinese gall with satisfactory results.
RESUMO
A mathematical model of electro-chemical cell was induced according to its electric model. Based on the mathematical model, Fourier transform (FT) was applied to separate the charging current from Faradaic current in fast scanning voltammetric signal. The proposed method was investigated with both simulated voltammogram and experimental voltammogram. The results indicate that the proposed methods can successfully separate the charging current from Fradaic current, and the result is consistent with theoretical model.