Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Chinese Journal of Radiology ; (12): 879-883, 2011.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-421710

RESUMO

ObjectiveTo evaluate the ability of high resolution magnetic resonance (MR) imaging at 3.0 tesla to depict the characterization of human carotid arterial vessel wall and detect atherosclerotic lesions ex vivo in comparison to histopathologic results. MethodsEighteen carotid arteries obtained from 9 elderly donors underwent fat-suppressed T1 - and T2-weighted MR imaging at 3.0 tesla MR system with a mouse coil. Corresponding histological sections were obtained for the comparison. Correlation between MR images and histopathologic slices was obtained by Pearson or Spearman correlation coefficient.Cohen K was computed to quantify the agreement between MRI and histopathologic findings.Results Lumen area,intima and media area measured on fat-suppressed T2-weighted images showed stronger correlation with the corresponding histopathologic slices [ MRI vs.histopathology:( 27. 53 ± 6. 77 ) mm2 vs.( 25.83 ±6. 69 ) mm2, r2 = 0. 91,P2 = 0. 024, ( 12.31 ± 3. 31 ) mm2 vs.( 12. 28 ± 3.71 ) mm2, r2 = 0. 70, P2 = 0. 020,Median 12. 29 mm2(Min 1.12 mm2, Max 33.18 mm2) vs.Median 11.62 mm2(Min 0.89 mm2, Max 32. 84 mm2 ), r2 = 0. 74, P2 = 0. 016, respectively]. The Cohen K score between the MR imaging and American Heart Association classifications was 0. 74, which corresponds to a good agreement. Conclusions 3.0 T high-resolution multi-sequence MRI can clearly show the structure of ex vivo carotid artery wall and allow quantitative assessment.Fat-suppressed T2Wimaging has a greater advantagein presenting atherosclerotic lesions.

2.
Chinese Journal of Radiology ; (12): 44-47, 2010.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-391414

RESUMO

Objective To analyze and explore the value of 3 T high resolution magnetic resonance vessel wall imaging for identifying the activity of Takayasu arteritis. Methods Twenty-six consecutive patients with Takayasu arteritis underwent 3.0 T high resolution MR vessel wall imaging on supraortic vessels (according to the classification of Lupi-Herrea , type Ⅰ and Ⅲ were included). Sixteen patients were in active phase and 10 in inactive phase based on the Kerr criteria. The MR vessel wall imaging appearances of Takayasu arteritis were compared between the active phase and inactive phase cases. Results Wall thickening was demonstrated in all involved arteries. There were statistically significant differences between active phase and inactive phase cases in MR appearances including multi-ring thickening of vessel wall (75/80 and 18/50), arterial inner wail enhancement (50/80 and 19/50), obscurity of perivascular fat (55/80 and 18/50,X<'2>=50.39,7.41,13.40,P<0.01). There was also a statistically significant difference in the thickness of carotid artery wall between the two groups [ (3.8±0.2) mm vs (2.5±0.8) mm]. Conclusion 3 T high resolution MR vessel wall imaging is valuable for identifying the activity of Takayasu arteritis.

3.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-473302

RESUMO

Objective To assess the value of CT, PET, PET/CT in diagnosis of peritoneal metastases with Meta analysis. Methods Articles of CT, PET or PET/CT on peritoneal metastases published in English or Chinese from Jan 2000 to May 2008 were collected, and histopathological and (or) surgical findings were taken as golden standards. The sensitivity, specificity, summary receiver operating characteristic (SROC) curves, area under the curve (AUC) and the heterogeneity were calculated with software of SAS 8.0, Meta-DiSc 1.4 and STATA 10.0. Results The results of Meta analysis from 11selected articals showed that PET had the highest pooled specificity [0.96, (0.91-0.98)];PET/CT had highest pooled sensitivity [0.77, (0.67-0.85)]. The AUC and Q~* of PET, PET/CT and CT was (0.92, 0.85), (0.99, 0.96), (0.91, 0.84), respectively. AUC of PET/CT was higher than that of CT (Z=2.33, P<0.05). Conclusion PET/CT is a high accuracy diagnostic tool for detecting peritoneal metastases.

4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-387487

RESUMO

Childhood rheumatic diseases are multi-system diseases which affect connective tissue of whole body and lung is one of the main target organs. The review focus on the utility of high-resolution computed tomography (HRCT)in childhood rheumatic lung disease, including HRCT technique, the normal and abnormal HRCT imaging appearances,then emphasizes and illustrates HRCT imaging futures of several childhood rheumatic lung diseases.

5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-545620

RESUMO

Objective To understand the situation of, mental health and behavior of the residents influenced by the environment noise. Methods From Feb. till Mar. 2005 and from Sep. till Oct. 2006, the residents living in 4 functional districts in Lu'an city, Anhui Province for one year or more were investigated by questionnaire. The investigation involved the general status, noise perception, behavior, adjustability and so on. 952 available questionnaires from 84 sites were attained. Results The significant differences were seen in the environmental noise perception among sex, age, occupation and health status (P

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...