Environ Sci Technol ; 58(25): 10969-10978, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38860863

RESUMO

Affordable thin-film composite (TFC) membranes are a potential alternative to more expensive ion exchange membranes in saltwater electrolyzers used for hydrogen gas production. We used a solution-friction transport model to study how the induced potential gradient controls ion transport across the polyamide (PA) active layer and support layers of TFC membranes during electrolysis. The set of parameters was simplified by assigning the same size-related partition and friction coefficients for all salt ions through the membrane active layer. The model was fit to experimental ion transport data from saltwater electrolysis with 600 mM electrolytes at a current density of 10 mA cm-2. When the electrolyte concentration and current density were increased, the transport of major charge carriers was successfully predicted by the model. Ion transport calculated using the model only minimally changed when the negative active layer charge density was varied from 0 to 600 mM, indicating active layer charge was not largely responsible for controlling ion crossover during electrolysis. Based on model simulations, a sharp pH gradient was predicted to occur within the supporting layer of the membrane. These results can help guide membrane design and operation conditions in water electrolyzers using TFC membranes.


Assuntos
Eletrólise , Transporte de Íons , Membranas Artificiais , Água/química
3.
Water Res ; 259: 121815, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38820732

RESUMO

Microbial electrosynthesis (MES) cells exploit the ability of microbes to convert CO2 into valuable chemical products such as methane and acetate, but high rates of chemical production may need to be mediated by hydrogen and thus require a catalyst for the hydrogen evolution reaction (HER). To avoid the usage of precious metal catalysts and examine the impact of the catalyst on the rate of methane generation by microbes on the electrode, we used a carbon felt cathode coated with NiMo/C and compared performance to a bare carbon felt or a Pt/C-deposited cathode. A zero-gap configuration containing a cation exchange membrane was developed to produce a low internal resistance, limit pH changes, and enhance direct transport of H2 to microorganisms on the biocathode. At a fixed cathode potential of -1 V vs Ag/AgCl, the NiMo/C biocathode enabled a current density of 23 ± 4 A/m2 and a high methane production rate of 4.7 ± 1.0 L/L-d. This performance was comparable to that using a precious metal catalyst (Pt/C, 23 ± 6 A/m2, 5.4 ± 2.8 L/L-d), and 3-5 times higher than plain carbon cathodes (8 ± 3 A/m2, 1.0 ± 0.4 L/L-d). The NiMo/C biocathode was operated for over 120 days without observable decay or severe cathode catalyst leaching, reaching an average columbic efficiency of 53 ± 9 % based on methane production under steady state conditions. Analysis of microbial community on the biocathode revealed the dominance of the hydrogenotrophic genus Methanobacterium (∼40 %), with no significant difference found for biocathodes with different materials. These results demonstrated that HER catalysts improved rates of methane generation through facilitating hydrogen gas evolution to an attached biofilm, and that the long-term enhancement of methane production in MES was feasible using a non-precious metal catalyst and a zero-gap cell design.


Assuntos
Fontes de Energia Bioelétrica , Eletrodos , Metano , Metano/metabolismo , Catálise , Hidrogênio/metabolismo
4.
Nat Commun ; 15(1): 2775, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38555371

RESUMO

Homologous protein search is one of the most commonly used methods for protein annotation and analysis. Compared to structure search, detecting distant evolutionary relationships from sequences alone remains challenging. Here we propose PLMSearch (Protein Language Model), a homologous protein search method with only sequences as input. PLMSearch uses deep representations from a pre-trained protein language model and trains the similarity prediction model with a large number of real structure similarity. This enables PLMSearch to capture the remote homology information concealed behind the sequences. Extensive experimental results show that PLMSearch can search millions of query-target protein pairs in seconds like MMseqs2 while increasing the sensitivity by more than threefold, and is comparable to state-of-the-art structure search methods. In particular, unlike traditional sequence search methods, PLMSearch can recall most remote homology pairs with dissimilar sequences but similar structures. PLMSearch is freely available at https://dmiip.sjtu.edu.cn/PLMSearch .


Assuntos
Evolução Biológica , Proteínas , Proteínas/química , Anotação de Sequência Molecular , Algoritmos , Análise de Sequência de Proteína
5.
Environ Sci Technol ; 58(2): 1131-1141, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38169368

RESUMO

Hydrogen gas evolution using an impure or saline water feed is a promising strategy to reduce overall energy consumption and investment costs for on-site, large-scale production using renewable energy sources. The chlorine evolution reaction is one of the biggest concerns in hydrogen evolution with impure water feeds. The "alkaline design criterion" in impure water electrolysis was examined here because water oxidation catalysts can exhibit a larger kinetic overpotential without interfering chlorine chemistry under alkaline conditions. Here, we demonstrated that relatively inexpensive thin-film composite (TFC) membranes, currently used for high-pressure reverse osmosis (RO) desalination applications, can have much higher rejection of Cl- (total crossover of 2.9 ± 0.9 mmol) than an anion-exchange membrane (AEM) (51.8 ± 2.3 mmol) with electrolytes of 0.5 M KOH for the anolyte and 0.5 M NaCl for the catholyte with a constant current (100 mA/cm2 for 20 h). The membrane resistances, which were similar for the TFC membrane and the AEM based on electrochemical impedance spectroscopy (EIS) and Ohm's law methods, could be further reduced by increasing the electrolyte concentration or removal of the structural polyester supporting layer (TFC-no PET). TFC membranes could enable pressurized gas production, as this membrane was demonstrated to be mechanically stable with no change in permeate flux at 35 bar. These results show that TFC membranes provide a novel pathway for producing green hydrogen with a saline water feed at elevated pressures compared to systems using AEMs or porous diaphragms.


Assuntos
Cloro , Hidrogênio , Metacrilatos , Osmose , Membranas Artificiais , Águas Salinas , Cloretos
6.
Environ Sci Technol ; 58(1): 391-399, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38147515

RESUMO

Low-cost polyamide thin-film composite membranes are being explored as alternatives to expensive cation exchange membranes for seawater electrolysis. However, transport of chloride from seawater to the anode chamber must be reduced to minimize the production of chlorine gas. A double-polyamide composite structure was created that reduced the level of chloride transport. Adding five polyamide layers on the back of a conventional polyamide composite membrane reduced the chloride ion transport by 53% and did not increase the applied voltage. Decreased chloride permeation was attributed to enhanced electrostatic and steric repulsion created by the new polyamide layers. Charge was balanced through increased sodium ion transport (52%) from the anolyte to the catholyte rather than through a change in the transport of protons and hydroxides. As a result, the Nernstian loss arising from the pH difference between the anolyte and catholyte remained relatively constant during electrolysis despite membrane modifications. This lack of a change in pH showed that transport of protons and hydroxides during electrolysis was independent of salt ion transport. Therefore, only sodium ion transport could compensate for the reduction of chloride flux to maintain the set current. Overall, these results prove the feasibility of using a double-polyamide structure to control chloride permeation during seawater electrolysis without sacrificing energy consumption.


Assuntos
Cloretos , Nylons , Nylons/química , Prótons , Eletrólise , Água do Mar/química , Hidróxidos , Sódio , Membranas Artificiais
7.
Environ Sci Technol ; 57(39): 14569-14578, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37722004

RESUMO

Low-cost polyamide thin-film composite (TFC) membranes are being explored as alternatives to cation exchange membranes for seawater electrolysis. An optimal membrane should have a low electrical resistance to minimize applied potentials needed for water electrolysis and be able to block chloride ions present in a seawater catholyte from reaching the anode. The largest energy loss associated with a TFC membrane was the Nernstian overpotential of 0.74 V (equivalent to 37 Ω cm2 at 20 mA cm-2), derived from the pH difference between the anolyte and catholyte and not the membrane ohmic overpotential. Based on analysis using electrochemical impedance spectroscopy, the pristine TFC membrane contributed only 5.00 Ω cm2 to the ohmic resistance. Removing the polyester support layer reduced the resistance by 79% to only 1.04 Ω cm2, without altering the salt ion transport between the electrolytes. Enlarging the pore size (∼5 times) in the polyamide active layer minimally impacted counterion transport across the membrane during electrolysis, but it increased the total concentration of chloride transported by 60%. Overall, this study suggests that TFC membranes with thinner but mechanically strong supporting layers and size-selective active layers should reduce energy consumption and the potential for chlorine generation for seawater electrolyzers.

8.
Water Res ; 229: 119392, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36446179

RESUMO

Hydroxyl radical (•OH) and sulfate radical (SO4•-) produced in advanced oxidation processes (AOPs) have been widely studied for organic contaminants degradation, however, the different radical characteristics and reaction mechanisms on organics degradation are still needed. In this study, a homogeneous Co(II)/peroxymonosulfate activation system was established for caffeine (CAF) degradation, and pH was controlled to regulate the radicals production. The different attack routes driven by SO4•- and •OH were deeply explored by transformation products (TPs) identification and theoretical calculations. Specifically, a method on dynamic electronic structure analysis of reactants (R), transition state (TS) and intermediates (IMs) during reaction was proposed, which was applied to elucidate the underlying mechanism of CAF oxidation by •OH and SO4•- at the molecular orbital level. In total, SO4•- is kinetically more likely to attack CAF than •OH due to its higher oxidation potential and electrophilicity index. Single electron transfer reaction (SET) is only favorable for SO4•-due to its higher electron affinity than •OH, while only •OH can react with CAF via hydrogen atom abstraction (HAA) route. Radical adduct formation (RAF) is the most favorable route for both •OH and SO4•- attack according to both kinetics and thermodynamics results. These findings can significantly promote the understanding on the degradation mechanism of organic pollutants driven by •OH and SO4•- in AOPs.


Assuntos
Poluentes Químicos da Água , Poluentes Químicos da Água/química , Peróxidos/química , Oxirredução , Transporte de Elétrons , Sulfatos/química , Radical Hidroxila/química , Compostos Orgânicos
9.
Dig Dis Sci ; 68(1): 259-267, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35790704

RESUMO

BACKGROUND: Current postpolypectomy guidelines treat 1-9 mm nonadvanced adenomas (NAAs) as carrying the same level of risk for metachronous advanced colorectal neoplasia (ACRN). AIMS: To evaluate whether small (6-9 mm) NAAs are associated with a greater risk of metachronous ACRN than diminutive (1-5 mm) NAAs. METHODS: We retrospectively evaluated 10,060 index colonoscopies performed from July 2011 to June 2019. A total of 1369 patients aged ≥ 40 years with index NAAs and having follow-up examinations were categorized into 5 groups based on size and number of index findings: Group 1, ≤ 2 diminutive NAAs (n = 655); Group 2, ≤ 2 small NAAs (n = 529); Group 3, 3-4 diminutive NAAs (n = 78); Group 4, 3-4 small NAAs (n = 65); and Group 5, 5-10 NAAs (n = 42). Size was classified based on the largest NAA. ACRN was defined as finding an advanced adenoma or colorectal cancer at follow-up. RESULTS: The absolute risk of metachronous ACRN increased from 7.2% in patients with all diminutive NAAs to 12.2% in patients with at least 1 small NAA (P = 0.002). Patients in Group 2 (adjusted odds ratio [AOR] 1.89; 95% confidence interval [CI], 1.21-2.95), Group 3 (AOR 2.40; 95% CI 1.78-4.90), Group 4 (AOR 2.77; 95% CI 1.35-5.66), and Group 5 (AOR 3.71; 95% CI 1.65-8.37) were associated with an increased risk of metachronous ACRN compared with Group 1. CONCLUSIONS: Patients with small NAAs have an increased risk of metachronous ACRN. Postpolypectomy guidelines should consider including risk stratification between small and diminutive adenomas.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Segunda Neoplasia Primária , Humanos , Estudos Retrospectivos , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/cirurgia , Colonoscopia , Adenoma/epidemiologia , Adenoma/cirurgia , Segunda Neoplasia Primária/epidemiologia , Fatores de Risco
10.
Sci Total Environ ; 855: 158608, 2023 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-36089028

RESUMO

Urban green space (UGS) is a complex and highly dynamic interface between people and nature. The existing methods of quantifying and evaluating UGS are mainly implemented on the surface features at a landscape scale, and most of them are insufficient to thoroughly reflect the spatial-temporal relationships, especially the internal characteristics changes at a small scale and the neighborhood spatial relationship of UGS. This paper thus proposes a method to evaluate the internal dynamics and neighborhood heterogeneity of different types of UGS in Leipzig using the gray level co-occurrence matrix (GLCM) index. We choose GLCM variance, contrast, and entropy to analyze five main types of UGS through a holistic description of their vegetation growth, spatial heterogeneity, and internal orderliness. The results show that different types of UGS have distinct characteristics due to the changes of surrounding buildings and the distance to the built-up area. Within a one-year period, seasonal changes in UGS far away from built-up areas are more obvious. As for the larger and dense urban forests, they have the lowest spatial heterogeneity and internal order. On the contrary, the garden areas present the highest heterogeneity. In this study, the GLCM index depicts the seasonal alternation of UGS on the temporal scale and shows the spatial form of each UGS, being in line with local urban planning contexts. The correlation analysis of indices also proves that each type of UGS has its distinct temporal and spatial characteristics. The GLCM is valid in assessing the internal characteristics and relationships of various UGS at the neighborhood scales, and using the methodology developed in our study, more studies and field experiments could be fulfilled to investigate the assessment accuracy of our GLCM index approach and to further enhance the scientific understanding on the internal features and ecological functions of UGS.


Assuntos
Parques Recreativos , Características de Residência , Humanos , Planejamento de Cidades , Florestas , Cidades
11.
J Pers Med ; 12(12)2022 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-36556230

RESUMO

Elevated serum ferritin and uric acid levels are common in patients with fatty liver disease. This study assessed the association between serum ferritin and uric acid levels and liver fibrosis in subjects with lean metabolic dysfunction-associated fatty liver disease (MAFLD). This cross-sectional study used data from a community screening examination for metabolic syndrome from December 2018 to September 2019 at Keelung Chang Gung Memorial Hospital. Subjects with lean MAFLD were defined as those with a body mass index (BMI) < 23 kg/m2 and hepatic steatosis according to the MAFLD criteria. A total of 182 lean subjects were included and were divided into lean MAFLD and lean healthy groups. Serum ferritin and uric acid concentrations were positively correlated with liver fibrosis, regardless of whether FIB-4, APRI, or NFS were used as references. Univariate logistic regression analysis showed that age and uric acid were associated with advanced liver fibrosis. After adjusting for potential confounders, only uric acid level was statistically significant in predicting the advanced liver fibrosis (OR = 6.907 (1.111−42.94), p = 0.038) in the lean MAFLD group. We found that an elevated serum uric acid level is an independent factor associated with advanced liver fibrosis in lean MAFLD subjects by noninvasive fibrosis scores.