RESUMO
Escherichia coli O157:H7 is an important serotype of enterohemorrhagic E. coli that was first identified as a human pathogen in 1982. This pathogen causes several serious diseases. In this study, immunomagnetic separation was coupled with a fluorescent nanobeads lateral flow assay to establish a sensitive and rapid detection method for Escherichia coli O157:H7 in raw milk. The pathogen was captured from raw milk by immunomagnetic separation with immunomagnetic nanobeads and then detected using a fluorescent nanobeads lateral flow assay. A fluorescent line was formed in the test line of the test strip and quantitatively detected using a fluorescent reader. Screening times, which included immunomagnetic separation and the fluorescent nanobeads lateral flow assay, were 8, 7, 6, and 5h when 1, 5, 25, and 125 cfu of E. coli O157:H7, respectively, were inoculated into 25mL of raw milk. The established method could be widely applied to the rapid onsite detection of other pathogens to ensure food safety.
Assuntos
Escherichia coli O157/isolamento & purificação , Separação Imunomagnética , Leite/microbiologia , Animais , Contagem de Colônia Microbiana , Microbiologia de Alimentos , HumanosRESUMO
Label selection is of vital importance for immunochromatographic assays. In this study, the fluorescent microsphere test strip and colloidal gold immunochromatographic test strip (FM-ICTS and CG-ICTS) were developed for the detection of Escherichia coli O157:H7 on the basis of the sandwich format. Two types of labels, namely, colloidal gold particles (CG) and carboxyl-modified fluorescent microspheres (FMs), were compared while coupling with anti-E. coli O157:H7 monoclonal antibody (mAb). The FM-ICTS and CG-ICTS were also compared. Results show that the coupling rate between FMs and mAb was higher than that between CG and mAb. Under optimum conditions, the sensitivity of FM-ICTS was eight times higher than that of CG-ICTS. Approximately 0.1 µg of mAb was used in every FM-ICTS, whereas 0.4 µg of mAb was used in every CG-ICTS. The coefficient of variation of FM-ICTS and CG-ICTS was 4.8% and 16.7%, respectively. The FM-ICTS and CG-ICTS can be stored at room temperature for 12 months and specific to five E. coli O157:H7 strains. Milk sample inoculated with E. coli O157:H7 were tested by the FM-ICTS and CG-ICTS. The FM-ICTS sensitivity was 10(4) CFU/ml while the CG-ICTS sensitivity was 10(5) CFU/ml. The sensitivity, consumption of antibodies, and coefficient of variation of FM-ICTS were better than those of CG-ICTS for the detection of E. coli O157:H7.