Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 42(3): 699-716, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26705891

RESUMO

The Bernoulli effect may result in eruption of a vulnerable carotid atheroma, causing a stroke. We measured electrocardiography (ECG)-registered QRS intra-stenotic blood velocity and atheroma strain dynamics in carotid artery walls using ultrasonic tissue Doppler methods, providing displacement and time resolutions of 0.1 µm and 3.7 ms. Of 22 arteries, 1 had a peak systolic velocity (PSV) >280 cm/s, 4 had PSVs between 165 and 280 cm/s and 17 had PSVs <165 cm/s. Eight arteries with PSVs <65 cm/s and 4 of 9 with PSVs between 65 and 165 cm/s had normal systolic diametric expansion (0% and 7%) and corresponding systolic wall thinning. The remaining 10 arteries had abnormal systolic strain dynamics, 2 with diametric reduction (>-0.05 mm), 2 with extreme wall expansion (>0.1 mm), 2 with extreme wall thinning (>-0.1 mm) and 4 with combinations. Decreases in systolic diameter and/or extreme systolic arterial wall thickening may indicate imminent atheroma rupture.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/fisiopatologia , Técnicas de Imagem por Elasticidade/métodos , Imagem de Perfusão/métodos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Técnicas de Imagem de Sincronização Cardíaca/métodos , Módulo de Elasticidade , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Rigidez Vascular
2.
Artigo em Inglês | MEDLINE | ID: mdl-22255998

RESUMO

Coronary artery disease is a deadly and costly condition and represents an important public health issue globally. Coronary Doppler vibrometry (CDV), a new noninvasive coronary artery stenosis detection technique, showed encouraging results in our recent clinical study. However, the CDV system required lengthy offline data analysis, thus it did not provide any feedback during examination on the quality of data, not to mention analysis results. To overcome these limitations, we have developed a new CDV system that interactively performs acquisition, analysis and display of a complete data set while a subject is still on the examination table. Our system is based on a commercial ultrasound machine, and it will be a useful tool for CDV research and clinical studies in the future.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Algoritmos , Cardiologia/métodos , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Diástole , Eletrocardiografia/métodos , Humanos , Modelos Anatômicos , Modelos Cardiovasculares , Miocárdio/patologia , Reprodutibilidade dos Testes , Transdutores , Ultrassom , Interface Usuário-Computador
3.
Artigo em Inglês | MEDLINE | ID: mdl-19963465

RESUMO

Various vector Doppler methods have been proposed in the last several decades to overcome the Doppler angle dependency in both conventional spectral Doppler and color Doppler by measuring both the speed and direction of blood flow. However, they have not been adopted for routine use because most of them require specialized hardware, which is not available in commercial ultrasound systems. An alternative approach (cross-beam method) that uses color Doppler images obtained from different steered beam angles is more feasible, but there is error in registering multiple color Doppler images because they are not acquired simultaneously. To alleviate this problem, we have evaluated a cross-beam vector Doppler system that registers spatially with a position sensor two color Doppler images from two different angles and temporally with ECG synchronization. The registration error was reduced to an average of 0.92 mm from 2.49 mm in 9 human subjects. Vector Doppler carotid artery images of a healthy subject and a patient with atherosclerotic plaques are also presented.


Assuntos
Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Técnica de Subtração/instrumentação , Transdutores , Ultrassonografia Doppler/instrumentação , Ultrassonografia Doppler/métodos , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Artigo em Inglês | MEDLINE | ID: mdl-17282145

RESUMO

We developed a reflectance continuous-wave near-infrared spectroscopy topography system with multi-source and multi-detector sensor head. A single wavelength (808 nm) laser diode is used as the original light source. With different-measurement approach, we can reconstruct images representing the variety of cerebral blood volume in clinical applications. Phantom experiments have been taken to verify the performance of the system. We also took clinical experiments for brain activities research during acupunctures and have obtained some primarily results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...