Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 25(1): 544, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39010006

RESUMO

OBJECTIVE: We aimed to compare the clinical efficacy of inverted triangular cannulated compression screws combined with Gotfried positive or negative buttress reduction in the healing of femoral neck fractures. METHODS: Between October 2017 and March 2021, 55 patients with femoral neck fractures underwent treatment using inverted triangular cannulated compression screws combined with Gotfried positive or negative buttress reduction. Among these patients, 29 received inverted triangular cannulated compression screws combined with Gotfried positive buttress reduction treatment. This group consisted of 16 males and 13 females, with an average age of 43.45 ± 8.23 years. Additionally, 26 patients received inverted triangular cannulated compression nails combined with Gotfried negative buttress reduction treatment. This group included 14 males and 12 females, with an average age of 41.96 ± 8.69 years. Postsurgery, various measurements were taken, including the degree of shortening of the femoral neck, degree of bone nonunion, degree of fixation failure, degree of ischemic necrosis of the femoral head, and Harris score of the hip joint. RESULTS: All patients were followed up for a minimum of 18 months. The group that underwent treatment with an inverted triangular cannulated compression screw combined with Gotfried positive buttress reduction did not experience any cases of bone nonunion, fixation failure, or ischemic necrosis of the femoral head. In the group that received treatment with inverted triangle cannulated compression screws combined with Gotfried negative buttress reduction, there was one case of bone nonunion, three cases of early fixation failure, and one case of ischemic necrosis. Ultimately, five patients (19.23% of the total) underwent joint replacement surgery. The average shortening lengths in the vertical plane were 4.07 ± 1.98 mm and 8.08 ± 3.54 mm, respectively. In the horizontal plane, the average shortening lengths were 3.90 ± 1.57 mm and 7.77 ± 3.31 mm, respectively. At the last follow-up, the group that received Gotfried positive buttress reduction had a greater Harris hip joint score. CONCLUSION: The success rate of combining inverted triangular cannulated compression screws with Gotfried positive buttress reduction surgery is relatively high. This surgical approach effectively prevents femoral neck shortening and improves hip joint function. Moreover, it is crucial to avoid negative buttress reduction when managing femoral neck fractures.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Consolidação da Fratura , Humanos , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Resultado do Tratamento , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Estudos Retrospectivos , Seguimentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...