Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 23(6): 1325-7, 2006 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-17228735

RESUMO

A fluorescence method is found for determination of bovine serum albumin (BSA). The method is based on the interaction of fluorescein with BSA to form a complex in Tris-HCl buffer of pH 2.2. The complex exitation wavelength is 467 nm, the emission wavelength is 515 nm. The linear measurement rang is between 1.8-500 mg/L for BSA, F = 26.776 C + 2.8082, r = 0.9999. This method is sensitive,steady,and low cost for determination of BSA.


Assuntos
Fluoresceína/química , Soroalbumina Bovina/análise , Animais , Bovinos , Interações Medicamentosas , Espectrometria de Fluorescência/métodos
2.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 35(1): 113-6, 2004 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-14981833

RESUMO

OBJECTIVE: To investigate the state of impaired cerebral energy metabolism of the hydrocephalus tissue. METHODS: Adult male dogs were used for establishing the model of kaolin-induced hydrocephalus. A simple and rapid method for the simultaneous determination of creatine (Cr), phosphocreatine (Crp), and adenosinephosphates (AMP, ADP, ATP) in different stages of experimental hydrocephalus tissue by reversed-phase high performance liquid chromatography (RP-HPLC) has been established. The chromatographic conditions were as follows: Inertsil ODS-3 C18 column (4.6 mm x 250 mm i.d. 5 microns), the mobile phase being composed of KH2PO4 buffer (330 mmol/L)-acetonitrile-TBA (45 mmol/L) (94:5.5:0.5) (pH = 6.27) and detector at 210 nm. RESULTS: The calibration curve showed a good linearity in the mass concentration range of 5.69-3640.50 mumol/L (r = 0.9993) for Cr, 3.47-555.50 mumol/L (r = 0.9999) for Crp, 2.69-1723.00 mumol/L (r = 0.9993) for AMP, 2.66-1704.00 mumol/L (r = 0.9999) for ADP and 2.94-1883.50 mumol/L (r = 0.9999) for ATP. The recoveries ranged from 90.10% to 107.00% with relative standard deviations from 1.58% to 3.88%. The detection limits of this method were 3.55-5.84 mumol/L. By means of this method, the Cr, Crp, AMP, ADP and ATP in different stages of 16 dogs experimental hydrocephalus tissue were determined with satisfactory results. CONCLUSION: This method is rapid, precise, accurate and suitable for the determination of the high energy nucleotides in hydrocephalus tissues.


Assuntos
Trifosfato de Adenosina/análise , Hidrocefalia/metabolismo , Fosfocreatina/análise , Difosfato de Adenosina/análise , Monofosfato de Adenosina/análise , Animais , Química Encefálica , Cromatografia Líquida de Alta Pressão/métodos , Creatina/análise , Cães , Masculino , Distribuição Aleatória , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...