Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Microsurgery ; 43(2): 185-195, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36086933

RESUMO

BACKGROUND: Perforator-based free perforator flaps have become an important tool for the reconstruction of tissue defects. The effect of the number of perforators on the outcomes of perforator flaps has been widely debated. This study aimed to compare the outcomes of single- and multiple-perforator-based free perforator flaps in free-flap reconstruction. METHODS: We searched PubMed, Web of Science, EMBASE, Chinese BioMedical Literature Database (CBM), Cochrane Library, and clinicaltrials.gov between January 2000 and June 2021 to identify studies that reported data on the outcomes of free perforator flaps. Two authors individually extracted data and performed quality assessment. Outcomes, including partial flap loss, total loss, fat necrosis, arterial insufficiency, venous insufficiency, hemorrhage and hematoma, wound dehiscence at recipient sites and donor site complications, were evaluated. RESULTS: Thirty-two studies with 2498 flaps were included in our analysis. No significant difference was found in the rates of partial loss and arterial insufficiency of flaps, hemorrhage and hematoma, wound dehiscence at recipient sites and donor site complications. However, the multiple-perforator group showed significantly lower rates of total loss (relative risk [RR] = 1.08, 95% confidence interval [CI]: 0.78-1.79, p = .754), fat necrosis (RR = 1.79, 95% [CI]: 1.36-2.36, p = .000) and venous insufficiency (RR = 1.72, 95% CI: 1.07-2.79, p = .026) than the single-perforator group. CONCLUSION: The rates of total loss, fat necrosis and venous insufficiency in the multiple-perforator group were lower than those in the single-perforator group. Hence, we recommend that multiple perforators be included in the free perforator flap when appropriate, to yield better clinical outcomes in reconstruction.


Assuntos
Necrose Gordurosa , Retalhos de Tecido Biológico , Retalho Perfurante , Procedimentos de Cirurgia Plástica , Humanos , Complicações Pós-Operatórias/etiologia , Hematoma
2.
Ear Nose Throat J ; : 1455613221115143, 2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35830468

RESUMO

OBJECTIVES: This study was conducted to identify the risk factors for free flap outcomes in head and neck reconstruction. METHODS: A retrospective review of 318 free flaps were used for head and neck reconstructions in 317 patients over seven years. The patient characteristics, surgical data, and flap outcomes were recorded. The impact of risk factors related on the outcomes of free flaps were analyzed using single and multivariate analysis. RESULTS: For single factor analysis, 295 free flaps for the first reconstruction were included. Hypertension and the type of recipient vein are associated with venous thrombosis (P = .018, P = .047). Hypertension, type of free flap, recipient artery, and recipient vein were associated with the incidence of re-exploration (P = .009, P = .011, P = .017, P = .021). Hypertension had an obvious effect on the flap survival (P = .005). For multivariate analysis, hypertension (odds ratio = .166, 95% confidence interval: .043 - .636; P = .009) was a statistically significant risk factor for flap survival. For types of recipient artery and vein, selecting two venous anastomosis (one of IJVS and one of EJVS) had the minimum incidence of venous thrombosis (2.2%), and selecting facial artery, single vein (one of IJVS), and two veins (one of IJVS and one of EJVS) for anastomosis had lower incidence of re-exploration, which were 4.4%, 2.9%, and 6.0%, respectively (P < .05). CONCLUSIONS: Risk factors as hypertension, type of free flap, recipient artery and vein should be paid more attention in the free flaps for head and neck reconstructions. We believe proper measures will lead to better results in head and neck reconstruction.

3.
Br J Oral Maxillofac Surg ; 60(5): 547-553, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35437195

RESUMO

The vascularised forearm free flap is a workhorse flap for the reconstruction of many types of soft tissue defects. However, the difference in donor-site morbidity between the radial forearm free flap (RFFF) and ulnar forearm free flap (UFFF) remains controversial. This study aimed to compare the donor-site outcomes of RFFF and UFFF. We searched PubMed, EMBASE, Web of Science, clinicaltrials.gov, Cochrane Library, and Chinese Biomedical Literature Database up to August 10, 2021, to identify studies on donor-site outcomes of RFFF versus UFFF in patients undergoing reconstructive surgery. Two authors individually extracted data and performed quality assessments of the selected articles. The overall morbidity and overall effect of individual complications of the donor site were analysed. In total, 288 cases from five studies were included in our analysis. The UFFF group was significantly superior to the RFFF group regarding overall morbidity and overall effect of individual complications of the donor site. The morbidity of UFFF donor sites was significantly lower than that of RFFF, and UFFF may be an ideal substitute for RFFF in reconstructive surgery. However, additional large-scale studies are necessary to confirm this finding.


Assuntos
Retalhos de Tecido Biológico , Procedimentos de Cirurgia Plástica , Antebraço/cirurgia , Retalhos de Tecido Biológico/cirurgia , Humanos , Morbidade , Artéria Radial/cirurgia
4.
J Phys Chem Lett ; 13(3): 857-863, 2022 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-35045256

RESUMO

By interplay between first-principles molecular dynamics and nonadiabatic molecular dynamics simulations based on the decoherence-induced surface-hopping approach, we investigate and quantify the mechanisms through which different electron polaron hopping regimes in the reduced anatase TiO2(101) surface influence recombination of photogenerated charge carriers, also in the presence of adsorbed water (H2O) molecules. The simulations reveal that fast hopping regimes promote ultrafast recombination of photogenerated charge-carriers. Conversely, charge recombination is delayed in the presence of slower polaron hopping and even more so if the polaron is pinned at one Ti-site, as typical following adsorption of H2O on the anatase(101) surface. These trends are related to the observed enhancement of the space and energy overlap between conduction band minimum and polaron band gap states, and the ensuing nonadiabatic couplings (NAC) strengths, during a polaronic hop. We expect these insights on the beneficial role of polaron diffusion pinning for the extended lifetime of photoexcitations in TiO2 to sustain ongoing developments of photocatalytic strategies based on this substrate.

5.
Nanoscale ; 13(37): 15590-15597, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34528990

RESUMO

Studies on transuranic oxides provide a particularly valuable insight into chemical bonding in actinide compounds, in which subtle differences between metal ions and oxygen atoms are of fundamental importance for the stability of these compounds as well as their existence. In the case of neptunium, it is still mainly limited to specific Np oxide compounds without periodicity in the formation of stable structures or different oxidation states. Here, we report a systematic global minimum search of Np2Ox (x = 1-7) clusters and the computational study of their electronic structures and chemical bonding. These studies suggest that Np(V) ion could play the structure-directing role, and thus the mixed-valent Np(III/V) in Np2O4 is predicted accessible. In comparison with lower oxidation state Np analogues, significant 5f-orbital covalent interactions with Np(V)O bonding are observed, which shows that these model neptunium oxides can provide new understandings into the behavior of 5f-electrons in chemical bonding and structural design.

6.
Small ; 17(26): e2100732, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34080772

RESUMO

The rational synthesis of single-layer noble metal directly anchored on support materials is an elusive target to accomplish for a long time. This paper reports well-defined single-layer Pt (Pt-SL) clusters anchored on ultrathin TiO2 nanosheets-as a new frontier in electrocatalysis. The structural evolution of Pt-SL/TiO2 via self-assembly of single Pt atoms (Pt-SA) is systematically recorded. Significantly, the Pt atoms of Pt-SL/TiO2 possess a unique electronic configuration with PtPt covalent bonds surrounded by abundant unpaired electrons. This Pt-SL/TiO2 catalyst presents enhanced electrochemical performance toward diverse electrocatalytic reactions (such as the hydrogen evolution reaction and the oxygen reduction reaction) compared with Pt-SA, multilayer Pt nanoclusters, and Pt nanoparticles, suggesting an efficient new type of catalyst that can be achieved by constructing single-layer atomic clusters on supports.

7.
Head Neck ; 43(8): 2405-2413, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33847445

RESUMO

BACKGROUND: Adequate flap volume is key to maintaining oral function after oral cancer surgery. This study aimed to evaluate changes in radial forearm free flap (RFFF) volumes after 1 year of follow-up following ablative tumor surgery in the head and neck. METHODS: A prospective study that recorded the clinical data of 20 patients with head and neck cancer who underwent RFFF reconstruction. Magnetic resonance (MR) and Mimics Research 19.0 software were used to measure the RFFF volumes at 1, 3, 6, and 12 postoperative months. RESULTS: Compared with one postoperative month, the RFFF volume decreased by 15.5%, 29.4%, and 42.0% at 3, 6, and 12 months, respectively, after surgery. A significant positive correlation between postoperative radiotherapy and RFFF volume changes was detected. CONCLUSION: The volume of RFFF decreases with time. It is recommended to use overcorrection, with a 40% increase in RFFF volume, to reconstruct head and neck tumor-related defects.


Assuntos
Retalhos de Tecido Biológico , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Procedimentos de Cirurgia Plástica , Antebraço/cirurgia , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Neoplasias Bucais/cirurgia , Estudos Prospectivos
8.
J Craniofac Surg ; 32(5): 1689-1695, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33273197

RESUMO

BACKGROUND: With the gradual popularity of relatively novel medial sural artery perforator flap (MSAPF), robust studies are needed to compare the surgical outcomes of MSAPF versus multiple free soft flaps (MFSFs) to verify the advantages and disadvantages of MSAPF. METHODS: The authors searched PubMed, Web of Science, EMBASE, Cochrane Library, Chinese BioMedical Literature Database (CBM), and China National Knowledge Infrastructure (CNKI) until September, 2020, to identify studies that compared surgical outcomes of MSAPF and MFSFs. Two authors followed the PRISMA guidelines, individually extracted the data and performed the quality assessments. Survival rate of flaps, satisfaction degree of patients in recipient and donor site, skin grafting, and morbidity of recipient and donor site were evaluated. RESULTS: A total of 441 cases from 7 studies were included in our analysis. No significant differences were found regarding survival rate of flaps, recipient morbidity, and recipient satisfaction degree between the 2 groups. However, MSAPF group was significantly superior to MFSFs group in terms of skin grafting, morbidity, and satisfaction degree of donor site. CONCLUSION: Our meta-analysis showed that the MSPAF and MFSFs groups were similar in terms of survival rate of flaps, recipient morbidity, and recipient satisfaction degree. Medial sural artery perforator flap group was superior to MFSFs group in terms of morbidity and satisfaction degree of donor site. The results may prove that MSAPF is gaining popularity for a reason and is a good choice for repairing soft tissue defects.


Assuntos
Retalhos de Tecido Biológico , Retalho Perfurante , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Artérias , China , Humanos , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Resultado do Tratamento
9.
J Stomatol Oral Maxillofac Surg ; 122(4): e59-e64, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33242657

RESUMO

OBJECTIVE: The low accuracy limits the use of fibular free flap (FFF). We apply digital navigation and 3D printing model technology in mandibular reconstruction to improve FFF's accuracy. METHODS: 34 patients who underwent with FFF to repair mandibular defects were divided into Navigation Group (13 cases, using digital navigation and 3D printing model) and Control Group (21 cases, only 3D printing model). We retrospectively reviewed patients' hospitalization information and evaluated patients by subjective and objective items, such as UW-Qol scale, CT data. RESULTS: The operation time of Navigation Group was higher significantly than Control Group (10.36 ± 1.87vs9.00 ± 1.34 h).There were no significant differences in early postoperative complications. The Qol score of appearance, motion, anxiety were higher significantly in Navigation Group. The CT results showed that mandibular angle deviation and chin deflection of Navigation Group were better significantly than Control Group (1.72 ± 1.29° vs 3.69 ± 1.67°, 2.45 ± 1.39 vs 5.19 ± 2.13 mm). CONCLUSIONS: The digital navigation can improve FFF's accuracy in mandibular reconstruction. It doesn't significantly increase complications. The digital navigation's installation and operation methods should be simplified to shorter operation time and expand its application.


Assuntos
Retalhos de Tecido Biológico , Reconstrução Mandibular , Fíbula/cirurgia , Humanos , Impressão Tridimensional , Estudos Retrospectivos
10.
Angew Chem Int Ed Engl ; 59(46): 20666-20671, 2020 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-32790246

RESUMO

Herein we present a new viologen-based radical-containing metal-organic framework (RMOF) Gd-IHEP-7, which upon heating in air undergoes a single-crystal-to-single-crystal transformation to generate Gd-IHEP-8. Both RMOFs exhibit excellent air and water stability as a result of favorable radical-radical interactions, and their long-lifetime radicals result in wide spectral absorption in the range 200-2500 nm. Gd-IHEP-7 and Gd-IHEP-8 show excellent activity toward solar-driven nitrogen fixation, with ammonia production rates of 128 and 220 µmol h-1 g-1 , respectively. Experiments and theoretical calculations indicate that both RMOFs have similar nitrogen fixation pathways. The enhanced catalytic efficiency of Gd-IHEP-8 versus Gd-IHEP-7 is attributed to intermediates stabilized by enhanced hydrogen bonding.

11.
Phys Chem Chem Phys ; 22(7): 3940-3952, 2020 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-32016244

RESUMO

Ag/AgCl-based structures have recently been receiving considerable attention as visible-light-driven plasmonic photocatalysts, wherein the fabrication of Ag/AgCl species shaped with an anisotropic morphology is considered to be an efficient way to enhance their performances. While the past decade has witnessed great progress in this direction, it is still strongly desired to initiate a green and low-cost protocol for the synthesis of Ag/AgCl based structures with high catalytic activity. Using a surfactant-assisted synthesis protocol, wherein a cationic bola-type surfactant of chloride counteranions serves both as a reactant (namely, source of chlorine) for the generation of AgCl structures and as a directing template to assist the formation of anisotropic structures, we herein report that cube-like Ag/AgCl with blunt edges could be fabricated simply by dropping an aqueous solution of silver nitrate into an ethanol solution of the hexane-1,6-bis(trimethylammonium chloride) surfactant. Importantly, compared to the sphere-like counterparts manufactured using a conventional tadpole surfactant, the as-fabricated cube-like structures exhibit substantially improved catalytic performances under visible-light or natural-sunlight irradiation. It has been revealed that photogenerated holes might serve as the main active species during the catalytic process. Meanwhile, our results have disclosed that in contrast to the sphere-like Ag/AgCl structures, the as-constructed cube-like structures are relatively enriched with high-index AgCl facets of smaller hole effective mass, which promote a faster carrier transfer, facilitate the migration of the photogenerated holes to the surface to be involved in photocatalytic reactions, and suppress carrier recombination, leading to their enhanced photocatalytic performances. Considering the tremendous diversity of surfactants (bola-, gemini-, polymeric surfactants etc.) with various halide counteranions and their sophisticated template effects, our new strategy might open up new opportunities for silver/silver halide (Ag/AgX, X = Cl, Br, and I)-based plasmonic structures with various morphologies and with superior light-to-chemical energy conversion capability.

12.
J Craniomaxillofac Surg ; 48(1): 56-66, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31911012

RESUMO

OBJECTIVE: This study aimed to compare the complications at the donor site of supra- versus subfascially harvested anterolateral thigh perforator free flaps. METHOD: We searched PubMed, Web of Science, EMBASE, the Chinese BioMedical Literature Database (CBM) and the Cochrane Library until December 31, 2018, to identify studies that compared complications at the donor site of the supra- versus subfascially raised anterolateral thigh perforator free flaps. Two authors individually extracted the data and performed the quality assessments. Skin grafting, the rate of poor healing in the donor site, dysfunction at the donor site and sensory functions at the donor site were evaluated. RESULT: Seven studies with a total of 525 patients were included in our analysis. No significant differences were found regarding skin grafting and sensory functions between the 2 groups. However, in regard to the rate of poor healing and dysfunction at the donor site, the SPF group showed significantly better outcomes than the SBF group after the operation. CONCLUSION: Our meta-analysis suggested that, in regards to skin grafting and sensory recovery, the SPF and SBF groups were similar. With regard to donor site healing and functional recovery, the SPF group exhibited better outcomes than the SBF group.


Assuntos
Retalhos de Tecido Biológico , Procedimentos de Cirurgia Plástica , Humanos , Transplante de Pele , Coxa da Perna , Resultado do Tratamento
13.
J Oral Maxillofac Surg ; 78(1): 142-152, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31550437

RESUMO

PURPOSE: The purpose of the present study was to investigate the differences in postoperative thrombosis and flap failure between internal jugular vein (IJV) system anastomosis and external jugular vein (EJV) system anastomosis in free flaps for the reconstruction of head and neck defects. MATERIALS AND METHODS: We searched PubMed, Web of Science, EMBASE, Chinese BioMedical Literature Database, and other databases until March 2019 for studies that had reported data for anastomosis for the 2 different venous systems in the microvascular free-flap reconstruction of head and neck defects. We assessed thrombosis and flap failure in patients undergoing anastomosis of the IJV system and patients undergoing anastomosis of the EJV system. RESULTS: Nine studies with a total of 2051 patients with venous anastomosis were included in the present meta-analysis. IJV system anastomosis showed a significantly lower incidence of venous thrombosis than did the EJV system (relative risk [RR], 0.55; 95% confidence interval [CI], 0.37 to 0.82). Eight studies were included in the analysis of the flap failure rate, which showed a lower failure rate for the IJV system anastomosis than for the EJV system (RR, 0.59; 95% CI, 0.35 to 1.00). CONCLUSIONS: The incidence of thrombosis and flap failure after venous anastomosis in the IJV system was lower than that in the EJV system. The results from the present study have shown that the IJV system should be the first choice for venous anastomosis in the reconstruction of free flaps.


Assuntos
Retalhos de Tecido Biológico , Neoplasias de Cabeça e Pescoço , Anastomose Cirúrgica , Humanos , Veias Jugulares/cirurgia , Pescoço/cirurgia , Estudos Retrospectivos
14.
J Oral Maxillofac Surg ; 77(8): 1724-1732, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30904550

RESUMO

PURPOSE: This study focused on quality of life for patients in northeast China who underwent oral cancer resection directly before flap reconstruction. In addition, this study compared differences among the radial forearm free flap (RFFF), ulnar forearm free flap (UFFF), and anterolateral thigh flap (ALTF) for defect reconstruction. MATERIALS AND METHODS: To assess patients' quality of life, the University of Washington Quality of Life and 14-item Oral Health Impact Profile (OHIP-14) questionnaires were completed 6 months after reconstruction. RESULTS: The flap size of the ALTF group was much larger than that of the UFFF and RFFF groups. The appearance score of the ALTF group was markedly higher than that of the UFFF and RFFF groups, whereas these groups had a much higher swallowing score than the ALTF group. Furthermore, the ALTF group had much lower social disability OHIP-14 scores than the RFFF group. CONCLUSIONS: The results indicate that all 3 reconstruction methods are similar, but that the ALTF has a slight advantage over the UFFF and RFFF.


Assuntos
Retalhos de Tecido Biológico , Neoplasias Bucais , Procedimentos de Cirurgia Plástica , Qualidade de Vida , China , Humanos , Neoplasias Bucais/cirurgia , Coxa da Perna
15.
J Craniofac Surg ; 30(2): e119-e125, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30531277

RESUMO

PURPOSE: The main aim of this article is to compare the complication rate associated with the use of miniplates versus reconstruction plates in vascularized osteocutaneous flap reconstruction of the mandible. PATIENTS AND METHODS: The authors searched PubMed, Web of Science, EMBASE, Chinese BioMedical Literature Database (CBM), Cochrane Library, and clinicaltrials.gov up to September 2017 to identify studies that compared the complication rate of miniplates versus reconstruction plates in patients undergoing mandibular reconstruction. Two reviewers individually extracted the data and performed a quality assessment. Plate exposure, plate fracture/removal, infection, and overall complications were evaluated. RESULTS: Five studies with 511 cases were included in our analysis. No significant difference was found between the groups. However, the reconstruction plate led to fewer overall complications and plate exposure postoperatively than did the miniplate. CONCLUSION: Our meta-analysis suggests that miniplates and reconstruction plates are suitable for mandibular reconstruction with a vascularized osteocutaneous flap.


Assuntos
Placas Ósseas/efeitos adversos , Reconstrução Mandibular , Complicações Pós-Operatórias , Humanos , Mandíbula/cirurgia , Reconstrução Mandibular/efeitos adversos , Reconstrução Mandibular/instrumentação , Reconstrução Mandibular/métodos , Complicações Pós-Operatórias/classificação , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Retalhos Cirúrgicos
16.
World J Surg Oncol ; 16(1): 149, 2018 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-30037329

RESUMO

BACKGROUND: The repair and reconstruction of maxillary and mandibular extensive defects have put huge challenges to surgeons. The fibular free flap (FFF) is one of the standard treatment choices for reconstruction. The conventional FFF has deficiencies, such as forming poor oral mucosa, limited flap tissue, and perforator vessel variation. To improve the use of FFF, we add the flexor hallucis longus (FHL) in the flap (FHL-FFF). In this paper, we described the advantage and indication of FHL-FFF and conducted a retrospective study to compare FHL-FFF and FFF without FHL. METHODS: Fifty-four patients who underwent FFF were enrolled and divided into two groups: nFHL group (using FFF without FHL, 38 patients) and FHL group (using FHL-FFF, 16 patients). The perioperative clinical data of patients was collected and analyzed. RESULTS: The flaps all survived in two groups. We mainly used FHL to fill dead space, and the donor-site morbidity was slight. In FHL group, flap harvesting time was shorter (118.63 ± 11.76 vs 125.74 ± 11.33 min, P = 0.042), the size of flap's skin paddle was smaller (16.5 (0-96) vs 21.0(10-104) cm2, P = 0.027) than nFHL group. There were no significant differences (P > 0.05) in hospital days, hospitalization expense, rate of perioperative complications, etc. between the two groups. Compared with FFF without FHL, FHL-FFF will neither affect the use of flap nor bring more problems. CONCLUSION: The FHL-FFF simplifies the flap harvesting operation. The FHL can form good mucosa and make FFF rely less on skin paddle. It can be used for adding flap tissue and dealing with perforator vessel variation in reconstruction of maxillary and mandibular extensive defects.


Assuntos
Fíbula/transplante , Retalhos de Tecido Biológico , Neoplasias Mandibulares/cirurgia , Reconstrução Mandibular/métodos , Neoplasias Maxilares/cirurgia , Ferimentos e Lesões/cirurgia , Adulto , Idoso , Feminino , Retalhos de Tecido Biológico/irrigação sanguínea , Humanos , Masculino , Mandíbula/cirurgia , Maxila/cirurgia , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Ferimentos e Lesões/etiologia
17.
Head Neck ; 40(7): 1356-1365, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29443415

RESUMO

BACKGROUND: The anterolateral thigh (ALT) free flap has been an extremely versatile flap. The purpose of this study was to propose comprehensive functional assessments of the donor site. METHODS: A total of 33 ALT flaps were enrolled prospectively. Objective assessments included isokinetic testing of the knee, and electromyographic examination of the lateral femoral cutaneous nerve (LFCN). The Patient and Observer Scar Assessment Scale (POSAS) was used to subjectively assess the donor-site scar. RESULTS: On the donor side, a significant decrease in most isokinetic muscle strength values was obvious 1 year postoperatively (P < .01). The normal side showed a compensatory increase 1 year postoperatively in the majority of isokinetic muscle strength values (P < .05). The majority of patients (70%) showed decreased sensory conduction velocity of the LFCN or no response to the microcurrent stimulation postoperatively. The aesthetic outcome was satisfactory. CONCLUSION: The decline in functional parameters at the donor-site was common. However, much more research is needed.


Assuntos
Nervo Femoral/fisiopatologia , Retalhos de Tecido Biológico , Força Muscular/fisiologia , Condução Nervosa/fisiologia , Sítio Doador de Transplante/fisiopatologia , Adulto , Idoso , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Coxa da Perna
18.
Br J Neurosurg ; 32(2): 165-171, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29338437

RESUMO

PURPOSE: Rupture of an intracranial aneurysm is a life-threatening acute cerebrovascular event. The purpose of this study was to investigate whether aneurysmal subarachnoid haemorrhage (SAH) incidence rate is higher or lower in elderly population than in middle aged population. MATERIALS AND METHODS: Aneurysmal SAH cases were collected retrospectively from the archives of 21 hospitals in Mainland China. All the cases were collected from September 2016 and backward consecutively for a period of time up to 8 years. SAH was initially diagnosed by brain computed tomography (CT). CT angiography (CTA) or digital subtraction angiography (DSA) was followed and SAH was confirmed to be due to cerebral aneurysm rupture. For cases when multiple bleeding occurred, the age of the first SAH was used in this study. The total incidence from all hospitals at each age group were summed together for females and males respectively; then adjusted by the total population number at each age group for females and males which was from the 2010 population census of the People's Republic of China. RESULTS: In total there were 8,144 cases of intracranial aneurysmal SAH, with 4,861 females and 3,283 males. For females the relative aneurysmal SAH incidence rate started to decrease after around 65 years old, while for males the relative aneurysmal SAH incidence rate started to decrease after around 53 years old. CONCLUSION: Our data tentatively suggest elderly patients may be at a reduced risk of rupture compared with patients who are younger while have similar other risk factors.


Assuntos
Hemorragia Subaracnóidea/epidemiologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/epidemiologia , Angiografia Digital , China/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Hemorragia Subaracnóidea/diagnóstico por imagem , Tomografia Computadorizada por Raios X
20.
Head Neck ; 39(2): 279-287, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27617706

RESUMO

BACKGROUND: The free fibula flap has become popular for mandibular reconstruction. The purpose of this study was to propose comprehensive functional assessments of the donor site. METHODS: Thirty free fibula flaps for mandible reconstruction were prospectively enrolled in the study. Objective assessments included isokinetic testing of the ankle joint, electromyographic examination of the superficial peroneal nerve (SPN), and preoperative and postoperative foot scans. The Patient and Observer Scar Assessment Scale (POSAS) was used to subjectively assess the donor site. RESULTS: The isokinetic values of the donor side showed a significant decrease 1 year postoperatively. The results of the electromyographic test of the SPN were categorized as 3 types. The plantar center pressure shifted to the heel on the donor side 6 months postoperatively. The aesthetic outcome was satisfactory. CONCLUSION: The functional parameters of the donor site indeed declined in our assessments. Further refinements in the surgical technique are needed to improve the donor site status. © 2016 Wiley Periodicals, Inc. Head Neck 39: 279-287, 2017.


Assuntos
Transplante Ósseo/métodos , Fíbula/transplante , Retalhos de Tecido Biológico/transplante , Reconstrução Mandibular/métodos , Sítio Doador de Transplante/fisiopatologia , Cicatrização/fisiologia , Adulto , Idoso , Transplante Ósseo/efeitos adversos , China , Estudos de Coortes , Eletromiografia/métodos , Feminino , Fíbula/irrigação sanguínea , Seguimentos , Retalhos de Tecido Biológico/irrigação sanguínea , Hospitais Universitários , Humanos , Masculino , Neoplasias Mandibulares/patologia , Neoplasias Mandibulares/cirurgia , Reconstrução Mandibular/efeitos adversos , Pessoa de Meia-Idade , Neoplasias Bucais/patologia , Neoplasias Bucais/cirurgia , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo , Coleta de Tecidos e Órgãos/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...