Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Environ Sci (China) ; 25 Suppl 1: S8-S14, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25078845

RESUMO

The present study investigated capillary electrophoretic detection of vanillin in vanilla perfume and air. An UV-absorbance detector was used in a home-made capillary electrophoretic instrument. A fused silica capillary (outer diameter: 364 µm, inner diameter: 50 µm) was used as a separation capillary, and a high electric voltage (20 kV) was applied across the two ends of the capillary. Total length of the capillary was 70 cm, and the effective length was 55 cm. Experimental results showed that the vanillin peak was detected at about 600, 450, and 500 seconds when pH of running buffers in CE were 7.2, 9.3, and 11.5, respectively. The peak area of vanillin was proportional to its concentration in the range of 0-10(-2) mol/L. The detection limit was about 10(-5) mol/L. Vanillin concentration in a 1% vanilla perfume sample was determined to be about 3×10(-4) mol/L, agreed well with that obtained by a HPLC method. Furthermore, determination of vanillin in air by combination of CE and active carbon adsorption method was investigated.


Assuntos
Ar/análise , Benzaldeídos/análise , Eletroforese Capilar/métodos , Perfumes/análise , Vanilla/química , Adsorção , Calibragem , Carbono/química , Cromatografia Líquida de Alta Pressão , Concentração de Íons de Hidrogênio , Peso Molecular , Padrões de Referência , Soluções , Solventes
2.
Biosens Bioelectron ; 19(4): 365-71, 2003 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-14615095

RESUMO

Alanine aminotransferase (ALT) has been regarded as one of the most sensitive indicators of hepatocellular damage. While ALT is widely used in the practice of medicine, few attempts have been made to develop biosensors applicable to the on-site diagnosis of liver diseases. In the hope of developing an immunosensor for measurement of ALT activity, we have generated monoclonal antibodies to human recombinant ALT and fabricated them for use in a sensor. The ALT immunosensor was composed of the followings: (1) anti-ALT antibody-immobilized outer membrane; (2) pyruvate oxidase-absorbed inner membrane; (3) a self assembled monolayer mediator-coated gold working electrode and an Ag/AgCl reference electrode. The chronoamperometric measurement of the immunosensor was performed with 40 microl of PBS containing substrates and ALT without a washing step in less than 5 min. The dynamic range of ALT immunosensor was presented as five orders of magnitude, ranging between 10 pg/ml and 1 microg/ml. The detection limit and the sensitivity were 10 pg/ml and 26.3 nA/(ng/ml), respectively. In the meantime, the enzyme sensor fabricated without anti-ALT antibody showed much poorer analytical values. The dynamic range, the detection limit, and the sensitivity were 10 ng/ml-100 microg/ml, 10 ng/ml and 11.4 nA/(ng/ml), respectively. The presented results indicated that the immunosensor system provided much better technical performance in all of the aspects evaluated than did the enzyme sensor without the immobilized-antibody.


Assuntos
Alanina Transaminase/análise , Alanina Transaminase/química , Anticorpos Monoclonais/química , Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Imunoensaio/instrumentação , Adsorção , Alanina Transaminase/imunologia , Anticorpos Monoclonais/imunologia , Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Eletrodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imunoensaio/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...