Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Cardiol ; 266: 15-23, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-29706428

RESUMO

PURPOSE: In a pig model of acute myocardial infarction (AMI), we validated a functional computed tomography (CT) technique for concomitant assessment of myocardial edema and ischemia through extravscualar contrast distribution volume (ECDV) and myocardial perfusion (MP) measurements from a single dynamic imaging session using a single contrast bolus injection. METHODS: In seven pigs, balloon catheter was used to occlude the distal left anterior descending artery for one hour followed by reperfusion. CT and cardiac magnetic resonance (CMR) imaging studies were acquired on 3 days and 12 ±â€¯3 day post ischemic insult. In each CT study, 0.7 ml/kg of iodinated contrast was intravenously injected at 3-4 ml/s before dynamic contrast-enhanced (DCE) cardiac images were acquired with breath-hold using a 64-row CT scanner. DCE cardiac images were analyzed with a model-based deconvolution to generate ECDV and MP maps. ECDV as an imaging marker of edema was validated against CMR T2 weighted imaging in normal and infarcted myocardium delineated from ex-vivo histological staining. RESULTS: ECDV in infarcted myocardium was significantly higher (p < 0.05) than that in normal myocardium on both days post AMI and was in agreement with the findings of CMR T2 weighted imaging. MP was significantly lower (p < 0.05) in the infarcted region compared to normal on both days post AMI. CONCLUSION: This imaging technique can rapidly and simultaneously assess myocardial edema and ischemia through ECDV and MP measurements, and may be useful for delineation of salvageable tissue within at-risk myocardium to guide reperfusion therapy.


Assuntos
Meios de Contraste/administração & dosagem , Extravasamento de Materiais Terapêuticos e Diagnósticos/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Meios de Contraste/efeitos adversos , Extravasamento de Materiais Terapêuticos e Diagnósticos/etiologia , Coração/diagnóstico por imagem , Coração/efeitos dos fármacos , Suínos
2.
Int J Cardiol ; 254: 272-281, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29223511

RESUMO

PURPOSE: We implemented and validated a compressed sensing (CS) based algorithm for reconstructing dynamic contrast-enhanced (DCE) CT images of the heart from sparsely sampled X-ray projections. METHODS: DCE CT imaging of the heart was performed on five normal and ischemic pigs after contrast injection. DCE images were reconstructed with filtered backprojection (FBP) and CS from all projections (984-view) and 1/3 of all projections (328-view), and with CS from 1/4 of all projections (246-view). Myocardial perfusion (MP) measurements with each protocol were compared to those with the reference 984-view FBP protocol. RESULTS: Both the 984-view CS and 328-view CS protocols were in good agreements with the reference protocol. The Pearson correlation coefficients of 984-view CS and 328-view CS determined from linear regression analyses were 0.98 and 0.99 respectively. The corresponding mean biases of MP measurement determined from Bland-Altman analyses were 2.7 and 1.2ml/min/100g. When only 328 projections were used for image reconstruction, CS was more accurate than FBP for MP measurement with respect to 984-view FBP. However, CS failed to generate MP maps comparable to those with 984-view FBP when only 246 projections were used for image reconstruction. CONCLUSION: DCE heart images reconstructed from one-third of a full projection set with CS were minimally affected by aliasing artifacts, leading to accurate MP measurements with the effective dose reduced to just 33% of conventional full-view FBP method. The proposed CS sparse-view image reconstruction method could facilitate the implementation of sparse-view dynamic acquisition for ultra-low dose CT MP imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Animais , Estudos de Viabilidade , Processamento de Imagem Assistida por Computador/instrumentação , Isquemia Miocárdica/fisiopatologia , Imagem de Perfusão do Miocárdio/instrumentação , Imagens de Fantasmas , Suínos , Tomografia Computadorizada por Raios X/instrumentação
3.
J Am Heart Assoc ; 6(2)2017 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-28159821

RESUMO

BACKGROUND: Radial artery occlusion is a known complication following transradial cardiac catheterization. A shorter duration of postprocedural radial clamp time may reduce radial artery occlusion (RAO) but might be associated with incomplete hemostasis. METHODS AND RESULTS: In total, 568 patients undergoing transradial diagnostic cardiac catheterization were randomly assigned to either 20 minutes (ultrashort) or 60 minutes (short) hemostatic compression time using patent hemostasis. Subsequently, clamp pressure was reduced gradually over 20 minutes. Access site hemostasis and RAO were assessed after clamp removal. Repeated assessment of RAO was determined at 1 week in 210 (37%) patients. Mean age was 64±11 years, and 30% were female. Percutaneous coronary intervention was performed in 161 patients. RAO immediately after clamp removal was documented in 14 (4.9%) and 8 (2.8%) patients in the 20- and 60-minute clamp application groups, respectively (P=0.19). The incidence of grade 1 hematoma was higher in the 20-minute group (6.7% versus 2.5%, P=0.015). RAO at 1 week after the procedure was 2.9% and 0.9% in the 20- and 60-minute groups, respectively (P=0.36). Requirement for clamp retightening (36% versus 16%, P=0.01) was higher among patients who had RAO. Need for clamp retightening was the only independent predictor of RAO (P=0.04). CONCLUSIONS: Ultrashort radial clamp application of 20 minutes is not preferable to a short duration of 60 minutes. The 60-minute clamp duration is safe and provides good access site hemostasis with low RAO rates. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02269722.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária/efeitos adversos , Hemorragia/terapia , Técnicas Hemostáticas/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Punções/efeitos adversos , Cateterismo Cardíaco/métodos , Cateterismo Periférico/efeitos adversos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Desenho de Equipamento , Feminino , Hemorragia/epidemiologia , Hemorragia/etiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Ontário/epidemiologia , Pressão , Artéria Radial/diagnóstico por imagem , Artéria Radial/fisiopatologia , Fatores de Risco , Fatores de Tempo , Grau de Desobstrução Vascular
4.
Med Phys ; 43(8): 4821, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27487900

RESUMO

PURPOSE: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. METHODS: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated from the dynamic contrast-enhanced (DCE) heart images taken at baseline and three weeks after the ischemic insult. RESULTS: Their results showed that the phantom and animal images acquired with the CT platform were minimally affected by image noise and artifacts. For the beam-hardening phantom study, changes in water HU in the wall surrounding the heart chambers greatly reduced from >±30 to ≤ ± 5 HU at all kVp settings except one region at 100 kVp (7 HU). For the cone-beam phantom study, differences in mean water HU from the central slice were less than 5 HU at two peripheral slices with each 4 cm away from the central slice. These findings were reproducible in the pig DCE images at two peripheral slices that were 6 cm away from the central slice. For the partial-scan phantom study, standard deviations of the mean water HU in 10 successive partial scans were less than 5 HU at the central slice. Similar observations were made in the pig DCE images at two peripheral slices with each 6 cm away from the central slice. For the image noise phantom study, CNRs in the ASiR-V images were statistically higher (p < 0.05) than the non-ASiR-V images at all kVp settings. MP maps generated from the porcine DCE images were in excellent quality, with the ischemia in the LAD territory clearly seen in the three orthogonal views. CONCLUSIONS: The study demonstrates that this CT system can provide accurate and reproducible CT numbers during cardiac gated acquisitions across a wide axial field of view. This CT number fidelity will enable this imaging tool to assess contrast enhancement, potentially providing valuable added information beyond anatomic evaluation of coronary stenoses. Furthermore, their results collectively suggested that the 100 kVp/25 mAs protocol run on this CT system provides sufficient image accuracy at a low radiation dose (<3 mSv) for whole-heart quantitative CT MP imaging.


Assuntos
Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Animais , Artefatos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Espalhamento de Radiação , Razão Sinal-Ruído , Suínos
5.
Cardiovasc Revasc Med ; 16(4): 217-20, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25940686

RESUMO

Patients diagnosed with ST-segment elevation myocardial infarction (STEMI) are occasionally found to have no culprit lesion on coronary angiography and are classified as presenting with false-positive STEMI. The clinical presentation and outcomes of these patients need to be further explored. In this case-controlled study, 259 consecutive patients with true code STEMI were compared to 104 consecutive STEMI patients without culprit lesions on emergent coronary angiography. We compared the clinical presentation, electrocardiographic features, etiology, and outcomes of the two groups. STEMI patients without culprit lesions were less likely to have typical chest pain (46% vs. 79%, P < 0.01). The ST-elevation in the group without culprit lesion was more likely to be concave (56% vs. 31%, P < 0.01), with less reciprocal ST-depression (19% vs. 71%, P < 0.01). The group without culprit lesions had a higher rate of ventilator support requirement (12.4% vs. 5.4%, P = 0.02), and higher rate of 30-day mortality (11.0% vs. 5.9%, P = 0.02). However, after excluding the patients with out-of-hospital cardiac arrests from both groups, the difference was no longer significant (P = 0.40 and 0.34 respectively). The relative poor outcomes of patients with false-positive code STEMI reflect the severity of their underlying medical condition. Careful history and review of ECG may help differentiate this group from true STEMI.


Assuntos
Angiografia Coronária , Infarto do Miocárdio/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Síndrome de Brugada , Doença do Sistema de Condução Cardíaco , Estudos de Casos e Controles , Angiografia Coronária/métodos , Eletrocardiografia/métodos , Feminino , Sistema de Condução Cardíaco/anormalidades , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...