Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Endosc Int Open ; 12(7): E875-E886, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38989254

RESUMO

Background and study aims Endoscopic ultrasound-guided hepaticogastrostomy with bridging between the left and right bile ducts is an alternative to endoscopic transpapillary drainage for malignant hilar biliary obstruction. We aimed to analyze the long-term stent patency of endoscopic ultrasound-guided hepaticogastrostomy with bridging. Patients and methods Patients who underwent endoscopic ultrasound-guided hepaticogastrostomy with bridging between April 2018 and July 2023 were retrospectively analyzed. We retrospectively compared the stent patency of these patients with that of the individuals who underwent endoscopic transpapillary drainage-multi-stenting using unmatched (entire) and propensity score-matched cohorts. Results Endoscopic ultrasound-guided hepaticogastrostomy with bridging had a technical success rate of 90% (18/20). Adverse events were minimal. The number of clinical success cases was 17 and 82 for endoscopic ultrasound-guided hepaticogastrostomy with bridging using metallic stent and endoscopic transpapillary drainage-multi-stenting, respectively. The recurrent biliary obstruction rate was 17.6% and 58.5% for endoscopic ultrasound-guided hepaticogastrostomy with bridging and endoscopic transpapillary drainage-multi-stenting, respectively; the median time to recurrent biliary obstruction (days) was significantly longer for endoscopic ultrasound-guided hepaticogastrostomy with bridging in the entire (not reached vs. 104, P =0.03) and propensity score-matched (183 vs. 79, P =0.05) cohorts. The non-recurrent biliary obstruction rate for endoscopic ultrasound-guided hepaticogastrostomy with bridging was 91.6% at 3 and 6 months and 57% at 12 months. Multivariate analyses revealed that endoscopic ultrasound-guided hepaticogastrostomy with bridging contributed to a lower recurrent biliary obstruction incidence (hazard ratio, 0.31, P =0.05) without significant difference. Conclusions Stent patency was significantly better for endoscopic ultrasound-guided hepaticogastrostomy with bridging. However, future prospective studies are needed.

2.
Endosc Int Open ; 12(6): E715-E722, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38841434

RESUMO

Background and study aims Endoscopic ultrasound-guided pancreatic duct drainage (EUS-PD) is emerging as an effective alternative treatment for obstructive pancreatitis after unsuccessful endoscopic retrograde pancreatography (ERP). However, the high incidence of adverse events associated with EUS-PD (approximately 20%) remains an issue. Recently, we developed a novel plastic stent for EUS-PD, with a radiopaque marker positioned at approximately one-third of the length from the distal end of the stent and side holes positioned exclusively distal to the marker. This study aimed to evaluate the feasibility and safety of using this stent in EUS-PD. Patients and methods We retrospectively reviewed data from 10 patients who underwent EUS-PD with the novel plastic stent at the National Cancer Center Hospital between March 2021 and October 2023. Technical and clinical success, procedure times, adverse events (AEs), recurrent pancreatic duct obstruction (RPO), and time to RPO were assessed. Results Of the 10 patients, five had postoperative benign pancreaticojejunal anastomotic strictures and five had malignant pancreatic duct obstruction. The technical and clinical success rates were both 100% (10/10). An AE (self-limited abdominal pain) occurred in one patient (10.0%). Two patients (20.0%) died of their primary disease during the follow-up period (median, 44 days; range, 25-272 days). The incidence of RPO was 10.0% (1/10), and the 3-month non-RPO rate was 83.3%. Conclusions The novel plastic stent shows potential as a useful and safe tool in EUS-PD.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38845460

RESUMO

BACKGROUND AND AIM: Endoscopic ultrasound-guided gastroenterostomy is a procedure used to connect the stomach and dilated afferent loop using a stent under endoscopic ultrasound for afferent loop syndrome. However, the actual efficacy and safety of this procedure remain unclear. Therefore, this retrospective study aimed to evaluate the efficacy and safety of endoscopic ultrasound-guided gastroenterostomy using a laser-cut-type fully covered self-expandable metallic stent and an anchoring plastic stent for afferent loop syndrome. METHODS: Technical and clinical success rates, adverse events, recurrent intestinal obstruction rates, time to recurrent intestinal obstruction, and technical and clinical success rates of re-intervention were evaluated in intended patients who underwent endoscopic ultrasound-guided gastroenterostomy for afferent loop syndrome from October 2018 to August 2022. RESULTS: In 25 intended patients with afferent loop syndrome who intended endoscopic ultrasound-guided gastroenterostomy, the technical success rate was 100% (25/25), whereas the clinical success rate was 96% (24/25). Two patients experienced grade ≥ 3 early adverse events, including one with intra-abdominal abscess and one with hypotension. Both events were attributed to intestinal fluid leakage. No late adverse events were observed. The recurrent intestinal obstruction rate was 32% (8/25), and the median time to recurrent intestinal obstruction was 6.5 months (95% confidence interval: 2.8-not available). The technical and clinical success rates of re-intervention were both 100% (8/8). CONCLUSIONS: Endoscopic ultrasound-guided gastroenterostomy using a fully covered self-expandable metallic stent and an anchoring plastic stent is effective and safe as a treatment procedure for afferent loop syndrome.

4.
Endosc Int Open ; 12(3): E367-E376, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38464977

RESUMO

Background and study aims Endoscopic gastroduodenal stent (GDS) deployment is currently a standard treatment for malignant gastric outlet obstruction (mGOO) in patients with limited life expectancy; however, stent dysfunction (SD) and complicated pancreatitis often occur after GDS deployment. We investigated incidence and contributing factors of SD and complicated pancreatitis. Patients and methods We retrospectively reviewed 203 patients who underwent initial GDS deployment for palliation of mGOO symptoms between October 2017 and July 2022, including 109 who underwent GDS deployment across the duodenal papilla (sub-cohort). Results SDs, including tumor ingrowth (n = 26), kinking (n = 14), and migration (n = 13), occurred in 68 patients (33.5%). Cumulative SD incidence was 41.1% (95% confidence interval, 32.6-49.4%). SD incidence increased to 0.4%, 0.16%, and 0.06% per day at < 8, 8-16, and>16 weeks, respectively. On multivariate analysis, Niti-S pyloric/duodenal stent deployment (sub-distribution hazard ratio [sHR] 0.26, P = 0.01) and survival length ≥ 90 days (sHR 2.5, P = 0.01) were respectively identified as favorable and risk factors significantly associated with SD. Pancreatitis developed in 14 patients (12.8%) in the sub-cohort, which had significantly higher parenchymal diameter ( P < 0.01) and lower main pancreatic duct (MPD) caliber ( P < 0.01) than the non-pancreatitis cohort. On multivariate analysis, MPD caliber < 3 mm independently predicted pancreatitis (odds ratio 6.8, P = 0.03). Conclusions Deployment of the Niti-S pyloric/duodenal stent, with conformability even for angulated strictures, significantly reduced the incidence of SD. Stent selection, life expectancy, and MPD caliber should be taken into consideration during decision-making for GDS deployment for mGOO.

5.
J Clin Monit Comput ; 38(3): 715-719, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38310593

RESUMO

The standard method for qualitatively evaluating the dynamic response is to see if the gain of the amplitude spectrum curve approaches 1 (input signal = output signal) over the frequency band of the blood pressure waveform. In a previous report, Watanabe reported that Gardner's natural frequency and damping coefficient, which are widely used as evaluation methods, do not reflect the dynamic response of the circuit. Therefore, new parameters for evaluating the dynamic response of pressure monitoring circuits were desired. In this study, arterial pressure catheters with length of 30, 60, 150, and 210 cm were prepared, and a blood pressure wave calibrator, two pressure monitors with analog output and a personal computer were used to analyze blood pressure monitoring circuits. All data collection and analytical processes were performed using step response analysis program. The gain at 10 Hz was close to 1 and the systolic blood pressure difference was small in the short circuits (30 cm, 60 cm), and the gain at 10 Hz was 1.3-1.5 in the 150 cm circuit and over 1.7 in the 210 cm circuit. The difference in systolic blood pressure increased in proportion to the length of the circuit. It could also be inferred that the gain at 10 Hz should be less than 1.2 to meet a clinically acceptable blood pressure difference. In conclusion, the gain at 10 Hz is sufficiently useful as an indicator to determine the correct systolic blood pressure.


Assuntos
Determinação da Pressão Arterial , Pressão Sanguínea , Humanos , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/instrumentação , Pressão Sanguínea/fisiologia , Processamento de Sinais Assistido por Computador , Desenho de Equipamento , Sístole , Calibragem , Monitores de Pressão Arterial , Algoritmos , Reprodutibilidade dos Testes , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Catéteres , Pressão Arterial , Software
6.
J Hepatobiliary Pancreat Sci ; 31(3): 203-212, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38014632

RESUMO

BACKGROUND/PURPOSE: There is currently no consensus on the use of endoscopic papillectomy (EP) for early stage duodenal ampullary adenocarcinoma. This study aimed to evaluate the feasibility of EP for patients with early stage duodenal ampullary adenocarcinoma. METHODS: Patients who underwent EP for ampullary adenocarcinomas were investigated. Complete and clinical complete resection rates were evaluated. Clinical complete resection was defined as either complete resection or resection with positive or unknown margins but no cancer in the surgically resected specimen, or no recurrence on endoscopy after at least a 1-year follow-up. RESULTS: Adenocarcinoma developed in 30 patients (carcinoma in situ [Tis]: 21, mucosal tumors [T1a(M)]: 4, tumors in the sphincter of Oddi [T1a(OD)]: 5). The complete resection rate was 60.0% (18/30) (Tis: 66.7% [14/21], T1a[M]: 50.0% [2/4], and T1a[OD]: 40.0% [2/5]). The mean follow-up period was 46.8 months. The recurrence rate for all patients was 6.7% (2/30). The clinical complete resection rates of adenocarcinoma were 89.2% (25/28); rates for Tis, T1a(M), and T1a(OD) were 89.4% (17/19), 100% (4/4), and 80% (4/5), respectively. CONCLUSIONS: EP may potentially achieve clinical complete resection of early stage (Tis and T1a) duodenal ampullary adenocarcinomas.


Assuntos
Adenocarcinoma , Ampola Hepatopancreática , Neoplasias do Ducto Colédoco , Neoplasias Pancreáticas , Humanos , Ampola Hepatopancreática/cirurgia , Ampola Hepatopancreática/patologia , Resultado do Tratamento , Estudos Retrospectivos , Adenocarcinoma/cirurgia , Adenocarcinoma/patologia , Endoscopia Gastrointestinal , Neoplasias do Ducto Colédoco/diagnóstico por imagem , Neoplasias do Ducto Colédoco/cirurgia , Neoplasias do Ducto Colédoco/patologia , Neoplasias Pancreáticas/patologia
7.
J Hepatobiliary Pancreat Sci ; 31(3): 173-182, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38124014

RESUMO

BACKGROUND: The risk and prognosis of pancreatobiliary cancer and in patients with autoimmune pancreatitis (AIP) and IgG4-related sclerosing cholangitis (IgG4-SC) remain unclear. Therefore, we retrospectively investigated the risk of pancreatobiliary cancer and prognosis in patients with AIP and IgG4-SC. METHODS: Patients with AIP and IgG4-SC at seven centers between 1998 and 2022 were investigated. The following data were evaluated: (1) the number of cancers diagnosed and standardized incidence ratio (SIR) for pancreatobiliary and other cancers during the observational period and (2) prognosis after diagnosis of AIP and IgG4-SC using standardized mortality ratio (SMR). RESULTS: This study included 201 patients with AIP and IgG4-SC. The mean follow-up period was 5.7 years. Seven cases of pancreatic cancer were diagnosed, and the SIR was 8.11 (95% confidence interval [CI]: 7.29-9.13). Three cases of bile duct cancer were diagnosed, and the SIR was 6.89 (95% CI: 6.20-7.75). The SMR after the diagnosis of AIP and IgG4-SC in cases that developed pancreatobiliary cancer were 4.03 (95% CI: 2.83-6.99). CONCLUSIONS: Patients with autoimmune pancreatitis and IgG4-SC were associated with a high risk of pancreatic and bile duct cancer. Patients with AIP and IgG4-SC have a worse prognosis when they develop pancreatobiliary cancer.


Assuntos
Doenças Autoimunes , Pancreatite Autoimune , Neoplasias dos Ductos Biliares , Colangite Esclerosante , Neoplasias Pancreáticas , Pancreatite , Humanos , Pancreatite/diagnóstico , Pancreatite Autoimune/complicações , Pancreatite Autoimune/diagnóstico , Estudos Retrospectivos , Doenças Autoimunes/diagnóstico , Colangite Esclerosante/complicações , Neoplasias Pancreáticas/diagnóstico , Neoplasias dos Ductos Biliares/diagnóstico , Imunoglobulina G , Diagnóstico Diferencial
8.
BMJ Open ; 13(12): e078967, 2023 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-38072497

RESUMO

INTRODUCTION: The current endoscopic treatment for postoperative benign hepaticojejunostomy anastomotic stricture (HJAS) has a high technical success rate and is highly effective in the short term. However, long-term results have shown a high rate of stenosis recurrence, which indicates an insufficient response to treatment. Three prospective studies on fully covered self-expandable metallic stent (FC-SEMS) treatment for benign HJAS used the stenosis resolution rate as the primary endpoint, and no study has yet used the long-term non-stenosis rate (at 12 months) as the primary endpoint. METHODS AND ANALYSIS: We launched the 'saddle-cross study', which will be conducted as a multicentre, prospective intervention of endoscopic treatment using two modified FC-SEMSs (BONASTENT️ M-Intraductal) that have been improved for benign stenosis in patients with benign HJAS, with the long-term non-restenosis rate (at 12 months) as the primary endpoint. This study aims to evaluate the long-term non-restenosis rate (at 12 months) and safety of the saddle-cross technique for benign HJAS. We plan to enrol 50 participants. ETHICS AND DISSEMINATION: This study has been approved by the Certified Review Board of the National Cancer Center, Japan (CRB3180009). The results will be reported at various conferences and published in international peer-reviewed journals.


Assuntos
Stents Metálicos Autoexpansíveis , Humanos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Estudos Retrospectivos , Stents Metálicos Autoexpansíveis/efeitos adversos , Stents , Ensaios Clínicos Fase II como Assunto , Estudos Multicêntricos como Assunto
9.
Gastrointest Endosc ; 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38065510

RESUMO

BACKGROUND AND AIMS: Fully covered self-expandable metallic stents (SEMSs) are laser-cut (L) or braided (B); however, it remains unclear which approach is more effective for distal malignant biliary obstruction (DMBO). This study compared the clinical outcomes of using L-type and B-type stents because we believe that recurrent biliary obstruction (RBO) is less likely to occur with L-type stents. METHODS: Patients diagnosed with unresectable DMBO were randomly assigned to groups L and B in a stratified block fashion, and outcomes were compared. The primary outcome was the rate of RBO within 1 year; secondary outcomes were adverse events, clinical success rate, time to RBO (TRBO), and overall survival. RESULTS: Of the 60 enrolled participants, 56 (group L, n = 27; group B, n = 29) were included. The rates of RBO within 1 year were 44.4% and 17.2% in groups L and B, respectively (odds ratio, 2.57; 95% confidence interval [CI], 1.045-6.353). Early adverse events, which improved with conservative treatment, included pancreatitis (n = 4) in group L and pancreatitis (n = 3) and cholecystitis (n = 1) in group B (P = .913). The median TRBO (220 days [95% CI, 56-272] vs 418 days [95% CI, 232-454]) was significantly longer in group B than in group L (log-rank test, P = .0118). The median overall survival (group L, 158 days; group B, 204 days) after stenting was not significantly different between groups (P = .8544). CONCLUSIONS: In the setting of DMBO, B-type stents are associated with less recurrent obstruction than L-type stents, although there was no difference in safety. (UMIN Clinical Trials Registry number: UMIN000027239.).

11.
J Hepatobiliary Pancreat Sci ; 30(3): 392-400, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36031808

RESUMO

BACKGROUND: In IgG4-related sclerosing cholangitis (IgG4-SC), the necessity of biliary drainage (BD) is unclear. In this study, we aimed to retrospectively investigate the improvement of liver damage and jaundice in cases of IgG4-SC with and without BD, before starting steroids. METHODS: A total of 52 patients with IgG4-SC were investigated in the study. The study endpoints were the normalization rate of alkaline phosphatase (ALP)/total bilirubin (T-Bil) after 8 weeks of steroids, with and without BD. RESULTS: Propensity score matching was performed based on ALP and T-Bil, and 28 patients were included. There were 14 patients each in the BD and non-BD groups. Before initiation of steroids, the mean ALP in the BD group and the non-BD group was 378/461 (P = .541); the mean T-Bil was 2.5/1.8 (P = .401). Eight weeks after initiation of steroids, ALP improvement rate in the BD group/non-BD group was 69.2%/61.5% (P = 1.000), and T-Bil improvement rate was 100%/100% (P = Ns). CONCLUSIONS: Steroids for IgG4-SC could prove effective in improving liver damage and jaundice, regardless of the presence or absence of BD. BD for IgG4-SC aimed to improve jaundice may not be necessary.


Assuntos
Colangite Esclerosante , Humanos , Colangite Esclerosante/tratamento farmacológico , Colangite Esclerosante/diagnóstico , Imunoglobulina G , Estudos Retrospectivos , Esteroides , Diagnóstico Diferencial
12.
J Hepatobiliary Pancreat Sci ; 30(6): 777-783, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36349478

RESUMO

BACKGROUND/PURPOSE: This study aimed to investigate the efficacy of intensive fluid-loading therapy post-endoscopic retrograde cholangiopancreatography (ERCP) for the prevention of post-ERCP pancreatitis (PEP) in at-risk patients. METHODS: In this retrospective study, data of 1200 patients at risk for PEP were investigated. After propensity score matching, 404 patients were included in the normal (n = 202) and hydration (n = 202) groups. On the day of ERCP, patients in both groups were infused with 2000 ml/24 h of fluid before ERCP. Meanwhile, the hydration group received an additional 1000 ml/10 h of lactated Ringer's solution postoperatively. RESULTS: The incidence of PEP was lower in the hydration group (12.4%) than in the normal group (24.3%) (odds ratio [OR]: 0.44; 95% CI: 0.26-0.75, p = .003). The incidence of severe PEP was 2.0% and 6.9% in the hydration and normal groups (OR: 0.27; 95% CI: 0.09-0.84, p = .027), respectively. The incidence of fatal PEP was 0% and 2.0% in the hydration and normal groups (OR: N.A.: p = .123), respectively. CONCLUSIONS: Post-ERCP hydration may be an effective method of preventing PEP, including severe PEP, in at-risk patients.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Pancreatite , Humanos , Lactato de Ringer , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Incidência , Pontuação de Propensão , Estudos Retrospectivos , Pancreatite/epidemiologia , Pancreatite/etiologia , Pancreatite/prevenção & controle
13.
J Clin Med ; 11(19)2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36233547

RESUMO

BACKGROUND AND PURPOSE: During endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), tract dilation is one of the most important steps, and the placement of conventional metal stents with 8.5 Fr delivery devices is difficult due to the large outer shape of the device. Fine-gauge balloon catheters have become popular because of their stricture penetration ability and ease of dilation. This study aimed to evaluate the utility of fine-gauge balloon catheters. PATIENTS AND METHODS: This retrospective study involved 38 patients who underwent conventional metal stent placement. The patients were classified into two groups: those who underwent dilation with a fine-gauge balloon catheter before initial metal stenting (balloon dilation group) and those who underwent bougie dilation only (non-balloon dilation group). We evaluated the stenting success rate after initial dilation and adverse events. RESULTS: Seventeen and twenty-one patients were included in the balloon dilation and non-balloon dilation groups, respectively. The stenting success rate after initial dilation was 100% (17/17) in the balloon dilation group and 71.4% (15/21) in the non-balloon dilation group (p = 0.024). As adverse events, peritonitis was observed in one case (4.8%) in the balloon dilation group, and in three cases (14.3%) in the non-balloon dilation group (p = 0.613). CONCLUSIONS: Dilation using a fine-gauge balloon catheter before conventional metal stent with 8.5 Fr delivery device placement is considered effective in EUS-HGS.

14.
Diagnostics (Basel) ; 12(7)2022 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-35885571

RESUMO

Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is useful in diagnosing subepithelial lesions (SELs), and adequate tissue sampling is necessary to differentiate between benign and malignant diseases to determine therapeutic strategies. This study aimed to evaluate sampling adequacy and diagnostic performance of EUS-FNA for SELs with Franseen needles. This retrospective study enrolled 130 patients who underwent EUS-FNA with a 22-gauge needle for SELs from January 2010 to March 2021. We compared sampling adequacy and predictive factors influencing the sampling adequacy of EUS-FNA for SELs between Franseen and conventional needles. The sampling adequacy rates were 95.0% (38/40) with Franseen needles and 76.7% (69/90) with conventional needles (p = 0.011). The mean number of punctures with Franseen needles (2.80) was significantly less than that with conventional needles (3.42) (p < 0.001). In the multivariate analysis, the use of Franseen needles (p = 0.029; odds ratio [OR], 5.37; 95% confidence interval [CI], 1.18−23.36) was an independent factor influencing the sampling adequacy. Compared to conventional needles, the Franseen needle could play a vital role in accurately diagnosing SELs by yielding better sampling adequacy and reducing the number of passes.

16.
J Hepatobiliary Pancreat Sci ; 29(8): 950-959, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35362661

RESUMO

BACKGROUND/PURPOSE: The detection ability and role of different imaging modalities to detect pancreatic neuroendocrine neoplasms (PNENs) including small lesions is unclear. This study aimed to compare the ability of endoscopic ultrasound (EUS) and computed tomography (CT) to detect PNENs. METHODS: Data of patients who underwent EUS and contrast-enhanced CT and were diagnosed with PNENs were analyzed. The detection rates of pancreatic lesions with EUS and CT based on tumor size and influencing factors were investigated. RESULTS: For 256 PNEN lesions, the detection rate of EUS was better than that of CT (94.5% vs 86.3%; P < .001). EUS was significantly superior to CT for PNENs ≤5 mm (58.3% vs 16.7%; P = .006) and 5-10 mm (97.7% vs 79.5%; P = .008). There was no significant difference in the detection rate between EUS and CT for PNENs >10 mm (98.4% vs 96.4%; P = .375). Size (≤5 mm) and insulinoma were independent factors associated with poor EUS and CT detection rates. CONCLUSIONS: Endoscopic ultrasound exhibited better detection ability than CT, with an excellent detection rate for PNENs >5 mm, except for insulinomas. CT could detect PNENs >10 mm, which are amenable to treatment.


Assuntos
Insulinoma , Tumores Neuroendócrinos , Neoplasias Pancreáticas , Endossonografia , Humanos , Tomografia Computadorizada por Raios X
17.
Dig Dis Sci ; 67(7): 2882-2890, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34973148

RESUMO

BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy is technically difficult. Extensive training is required to develop the ability to perform this procedure. AIMS: To investigate the learning curve of single-balloon-assisted enteroscopy ERCP (SBE-ERCP). METHODS: We conducted a retrospective, observational case series at a single center. We evaluated the SBE-ERCP procedures between April 2011 and February 2021. The main outcomes were the rate of reaching the target site and the success rate of the entire procedure. These parameters were additionally expressed as a learning curve. RESULTS: A total of 687 SBE-ERCP procedures were analyzed. The learning curve was analyzed in blocks of 10 cases. In this study, seven endoscopists, experts in conventional ERCP, were included. The overall SBE-ERCP procedural success rate was 92.2% (634/687 cases). Combining all data from individual endoscopists' evaluation periods, the insertion and success rates of the SBE-ERCP procedures gradually increased with increased experience performing SBE-ERCP. The insertion success rates for the number of SBE-ERCP cases (< 20, 21-30, > 30) were 82.9%, 92.9%, and 94.3%, respectively; the procedure success rates were 74.3%, 81.4%, and 92.9%, respectively. The endoscopists who had performed > 30 SBE-ERCP cases had a success rate of ≥ 90%. CONCLUSIONS: Our results suggest that performing > 30 cases is one of the targets for conventional ERCP experts to become competent in performing SBE-ERCP in patients with a surgically altered anatomy.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Enteroscopia de Balão Único , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Enteroscopia de Duplo Balão , Humanos , Curva de Aprendizado , Estudos Retrospectivos
18.
J Hepatobiliary Pancreat Sci ; 28(6): 524-532, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33931982

RESUMO

BACKGROUND/PURPOSE: The relationship between autoimmune pancreatitis (AIP) and malignancy has been reported. However, the potential risk for cancer in patients with immunoglobulin 4 (IgG4)-related sclerosing cholangitis (IgG4-SC) is unclear. The present study aimed to evaluate the incidence of cancer in IgG4-SC patients. METHODS: We retrospectively collected clinical data for 121 patients diagnosed with IgG4-SC from 7 hospitals. We calculated the standardized incidence ratio (SIR) of cancer in IgG4-SC patients based on the national cancer rates. The SIR of the period after the diagnosis of IgG4-SC were calculated. RESULTS: The mean follow-up period was 6.4 years, with 121 IgG4-SC patients. During the follow-up period, 26 patients had cancer, and 29 cancers were diagnosed. The SIR of cancer after the diagnosis of IgG4-SC was 1.90 (95% confidence interval [CI] 1.67-2.21). The SIR of pancreatic and bile duct cancer was 10.30 and 8.88, respectively. The SIR of cancer in <1 year, 1-5 years, and >5 years after diagnosis of IgG4-SC were 2.58, 1.01, and 2.44, respectively. CONCLUSIONS: IgG4-SC patients have a high risk of cancer including pancreatic and bile duct cancer. The risk of cancer was high less <1 year and >5 years after diagnosis of IgG4-SC. Therefore, IgG4-SC patients may require careful long-term follow-up.


Assuntos
Doenças Autoimunes , Neoplasias dos Ductos Biliares , Colangiocarcinoma , Colangite Esclerosante , Pancreatite , Doenças Autoimunes/diagnóstico , Doenças Autoimunes/epidemiologia , Neoplasias dos Ductos Biliares/epidemiologia , Neoplasias dos Ductos Biliares/etiologia , Ductos Biliares Intra-Hepáticos , Colangite Esclerosante/complicações , Colangite Esclerosante/diagnóstico , Colangite Esclerosante/epidemiologia , Diagnóstico Diferencial , Humanos , Imunoglobulina G , Pancreatite/epidemiologia , Pancreatite/etiologia , Estudos Retrospectivos , Fatores de Risco
19.
J Hepatobiliary Pancreat Sci ; 28(7): 617-624, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33788414

RESUMO

BACKGROUND/PURPOSE: The role of endoscopic preoperative biliary drainage for pancreatic head cancer is controversial because of the high incidence of stent occlusion before surgery. We sought to validate a suitable stent for biliary drainage in patients with pancreatic cancer undergoing neoadjuvant chemotherapy (NAC)/neoadjuvant chemoradiotherapy (NAC-RT). METHODS: We evaluated patients who received preoperative neoadjuvant therapy for pancreatic head cancer between January 2013 and December 2019. A covered metal (CMS) or plastic stent (PS) was inserted in symptomatic patients for biliary drainage. Recurrent biliary obstruction (RBO), success rate of endoscopic drainage, adverse events, and surgical outcomes were compared between the CMS and PS groups. RESULTS: Occurrence rate of RBO was significantly higher with PS (97%) vs CMS (15%, P < .001), and time to RBO was significantly longer with CMS vs PS (not reached vs 40.5 days, P < .001). Delayed schedule associated with RBO for neoadjuvant chemotherapy was significantly lower in CMS vs PS (14% vs 50%, P < .05). There was no difference in postoperative bleeding, operation time, complications, and rate of a microscopically margin-negative resection between groups. CONCLUSIONS: Use of CMS during NAC/NAC-RT allows for safe chemotherapy without causing cholangitis or biliary obstruction and for surgery to be performed.


Assuntos
Colestase , Neoplasias Pancreáticas , Drenagem , Humanos , Terapia Neoadjuvante , Neoplasias Pancreáticas/terapia , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...