Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Oral Maxillofac Implants ; 37(4): 653-659, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35904821

RESUMO

PURPOSE: The purpose of this systematic review and meta-analysis was to evaluate the effects of splinting impression copings on the accuracy of conventional impressions for two-unit nonparallel implant restorations. MATERIALS AND METHODS: MEDLINE via PubMed, Embase, and Web of Science databases were searched with no publication year or language limits, and studies comparing the accuracy of conventional impressions for two-unit nonparallel implant restorations made using splinted impression copings and nonsplinted impression copings were identified. A meta-analysis was performed using Review Manager software. The mean difference (MD) with 95% confidence interval (95% CI) for the framework strain and marginal gap of the implant-framework connection between impressions using splinted and nonsplinted copings were statistically analyzed (α = .05). RESULTS: Initially, 142 articles were identified after the removal of duplicates. Five in vitro studies were included in the systematic review, and four in vitro studies were included in the meta-analysis. All the included studies were focused on internal-connection implants and implant-level impressions. The implant angulation in the included studies ranged from 8 to 30 degrees. Impressions using splinted impression copings exhibited significantly smaller marginal gaps than those using nonsplinted impression copings (P = .02; mean difference [MD] = -13.34; 95% CI = -24.31 to -2.36). Moreover, with respect to the framework strain, no significant differences were found between impressions using splinted impression copings and nonsplinted impression copings (P = .47; MD = -12.64; 95% CI = -47.32 to 22.03). CONCLUSIONS: Significantly larger marginal gaps were found in the impressions using splinted impression copings, but the clinical significance was low. Based on the limited number of studies included, splinting copings is unnecessary when making conventional impressions for two-unit nonparallel implant restorations.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Adaptação Psicológica , Materiais para Moldagem Odontológica , Prótese Dentária Fixada por Implante/métodos
2.
RSC Adv ; 9(47): 27432-27438, 2019 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-35529239

RESUMO

A single-step hydrothermal route for synthesizing molybdenum doped zinc oxide nanoflakes was employed to accomplish superior electrochemical characteristics, such as a specific capacitance of 2296 F g-1 at current density of 1 A g-1 and negligible loss in specific capacitance of 0.01025 F g-1 after each charge-discharge cycle (up to 8000 cycles). An assembled asymmetric supercapacitor (Mo:ZnO@NF//AC@NF) also exhibited a maximum energy density and power density of 39.06 W h/kg and 7425 W kg-1, respectively. Furthermore, it demonstrated a specific capacitance of 123 F g-1 at 1 A g-1 and retained about 75.6% of its initial capacitance after 8000 cycles. These superior electrochemical characteristics indicate the potential of this supercapacitor for next-generation energy storage devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...