Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38544268

RESUMO

In the era of Industry 5.0, advanced technologies like artificial intelligence (AI), robotics, big data, and the Internet of Things (IoT) offer promising avenues for economic growth and solutions to societal challenges. Digital twin technology is important for real-time three-dimensional space reproduction in this transition, and unmanned aerial vehicles (UAVs) can support it. While recent studies have explored the potential applications of UAVs in nonterrestrial networks (NTNs), bandwidth limitations have restricted their utility. This paper addresses these constraints by integrating millimeter wave (mmWave) technology into UAV networks for high-definition video transmission. Specifically, we focus on coordinating intelligent reflective surfaces (IRSs) and UAV networks to extend coverage while maintaining virtual line-of-sight (LoS) conditions essential for mmWave communication. We present a novel approach for integrating IRS into Beyond 5G/6G networks to enhance high-speed communication coverage. Our proposed IRS selection method ensures optimal communication paths between UAVs and user equipment (UE). We perform numerical analysis in a realistically modeled 3D urban environment to validate our approach. Our results demonstrate significant improvements in the received SNR for multiple UEs upon the introduction of IRSs, and they confirm the feasibility of coverage extension in mmWave UAV networks.

2.
Int Angiol ; 40(2): 138-142, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33463976

RESUMO

BACKGROUND: We compared the subjective, clinical judgement of "saccular" morphology with the objective judgement of mechanical structural analysis. METHODS: Using structural analysis with the finite element method, we previously created a simple model of abdominal aortic aneurysm (AAA) that visualized the distribution of the maximum principal stress (MPS) in the aortic wall and identified the area of prominent stress. AAA "saccular" morphology was determined according to the area showing MPS>0.03 MPa. AAAs with low aspect ratio (horizontally long AAA sac) and small fillet radius were defined as "saccular." Twelve vascular surgeons were recruited. First, they judged the AAA as saccular or fusiform with 3-dimensional images at their clinical impression (subjective "eyeball" judgement). Second, they applied the deformable figure tools on the simple AAA-shaped sagittal view in the application model for 30 AAA cases. From the data of the tools applied, the mechanical structural analysis was performed semi-automatically and the morphology was judged with the objective "simple application." RESULTS: The structural analysis revealed that only one case was judged as saccular by 11 out of 12 surgeons and the other 29 AAAs were judged as fusiform by two-thirds or more of the surgeons. In contrast, 5 cases were subjectively judged as saccular by eight and more of the surgeons. CONCLUSIONS: The clinical judgement of AAA saccular morphology by the vascular surgeons was different from the judgement derived from the mechanical structural analysis using the application model. The saccular morphology may be theoretically rare in AAAs.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Humanos , Medição de Risco , Estresse Mecânico , Tomografia Computadorizada por Raios X
3.
Ann Vasc Dis ; 12(2): 176-181, 2019 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-31275470

RESUMO

Objective: To assess mechanisms underlying aneurysm formation using a simple electronic circuit model. Materials and Methods: We created a simple circuit model connecting the celiac artery (CA) to the superior mesenteric artery via the pancreaticoduodenal arcade. We retrospectively reviewed 12 patients with true pancreaticoduodenal artery aneurysms (PDAAs) who received open or endovascular treatment between 2004 and 2017. We set the resistance of each artery and organ voltage and calculated flow volume and rate in response to degrees of simulated CA stenosis from 0% to 99.9%. Results: Flow volume rates of the anterior pancreaticoduodenal artery and posterior pancreaticoduodenal artery decreased to zero when CA stenosis increased from 0% to 50% and then increased drastically, at which point flow direction reverted and the flow was up to three times the initial rate. The gastroduodenal artery (GDA) also showed reversed flow with severe CA stenosis. In 12 patients with PDAA, eight presented with a CA lesion, and the other patients presented with comorbidities causing the arteries to be pathologically fragile, such as Marfan syndrome, Behçet's disease, and segmental arterial mediolysis. All four GDA aneurysms were not accompanied by CA lesions. Conclusion: The mechanism underlying CA-lesion-associated PDAA formation may be partially explained using our model.

4.
J Vasc Surg ; 69(1): 86-91, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29914827

RESUMO

OBJECTIVE: The objective of this study was to use parameters to determine the geometric differences between ruptured abdominal aortic aneurysms (AAAs) and nonruptured AAAs. METHODS: Computed tomography data of 38 ruptured AAAs and 215 electively repaired (nonruptured) AAAs were collected from multiple institutes. We compared the ruptured AAA group and nonruptured AAA group with 1:1 matching by using the Mahalanobis distance, which was calculated using the patient's age, sex, and AAA diameter. We selected the longitudinal AAA image in multiplanar reconstruction view, placed a hypothetical ellipse on the aneurysm's protruded curve, and placed a circle on the portion connecting the aneurysm and the aorta. We then measured the aspect ratio (the vertical diameter divided by the horizontal diameter) and fillet radius (the radius of arc). RESULTS: The aspect ratio was significantly lower in the ruptured group than in the nonruptured group (2.02 ± 0.53 vs 2.60 ± 1.02; P = .002), as was the fillet radius (0.28 ± 0.18 vs 0.81 ± 0.44; P < .001). Receiver operating characteristic analysis revealed that the area under the curve of the aspect ratio was 0.688, and the optimal cutoff point was 2.23, with sensitivity and specificity of 0.55 and 0.76, respectively. The area under the curve of the fillet radius was 0.933, and the optimal cutoff was 0.347, with sensitivity and specificity of 0.97 and 0.87, respectively. CONCLUSIONS: The geometric analysis performed in this study revealed that ruptured AAAs had a smaller fillet radius and smaller aspect ratio than nonruptured AAAs did.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/fisiopatologia , Ruptura Aórtica/fisiopatologia , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
5.
Asian Cardiovasc Thorac Ann ; 26(2): 133-138, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29363319

RESUMO

Background Considering the unique characteristics of splenic artery aneurysms, we hypothesized that hemodynamic forces could play an important role in splenic artery aneurysm formation and that splenic artery geometry should be correlated with aneurysm development. Methods Tortuosity of the splenic artery was evaluated three-dimensionally by calculating the curvature using software and the original modeling system. We selected 54 splenic artery aneurysm patients who had undergone thin-slice computed tomography imaging with contrast. We compared the splenic artery aneurysm group to non-vascular patients via propensity-score matching (35 patients in each group). The splenic artery length index, average curvature, and maximum curvature were analyzed. Results Splenic artery aneurysm patients tended to have a longer splenic artery and the curvature was more severe compared to the non-vascular control patients. The average curvature of splenic artery aneurysm patients was associated with the dilatation rate in female patients. Conclusion Females with a tortuous splenic artery may have an increased risk of aneurysm formation.


Assuntos
Aneurisma/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Imageamento Tridimensional/métodos , Modelagem Computacional Específica para o Paciente , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Artéria Esplênica/diagnóstico por imagem , Idoso , Aneurisma/complicações , Aneurisma/patologia , Aneurisma/fisiopatologia , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/etiologia , Distribuição de Qui-Quadrado , Dilatação Patológica , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Pontuação de Propensão , Estudos Retrospectivos , Fatores de Risco , Software , Artéria Esplênica/patologia , Artéria Esplênica/fisiopatologia
6.
Circ J ; 82(1): 176-182, 2017 12 25.
Artigo em Inglês | MEDLINE | ID: mdl-28845031

RESUMO

BACKGROUND: Previously, we developed an image-based modeling system (V-Modeler) to investigate geometric changes in stent grafts (SGs) following their implantation for abdominal aortic aneurysms (AAAs). The aims of the present study were to improve this system for clinical use, to chronologically analyze postoperative morphological changes in SGs, and to demonstrate scenarios of SG migration.Methods and Results:Contrast-enhanced computed tomography data from 36 patients who underwent endovascular aneurysm repair (EVAR) for AAAs were used, with 72 centerline paths, in total, analyzed for bilateral SG legs. The existing V-modeler system was modified by introducing a penalty term, optimizing the number of control points using Akaike's information criterion, and changing the degree of the function from 3 to 5. Geometric parameters were then analyzed immediately, as well as >1 year after EVAR. Eight migrations were found and although overall SG curvature and curvature at the distal (leg) site did not change, curvature at the proximal (trunk) site of SGs decreased over time. Subanalysis revealed that SGs with severe curvature showed the same trend, whereas distal curvature increased in the non-severe curvature group. In addition, proximal curvature decreased more in Excluder than Zenith devices. CONCLUSIONS: The present study demonstrates SG behavior after implantation with numerical values for SG length and curvature.


Assuntos
Aneurisma da Aorta Abdominal/terapia , Migração de Corpo Estranho/prevenção & controle , Modelos Cardiovasculares , Stents/normas , Idoso , Idoso de 80 Anos ou mais , Aorta/anatomia & histologia , Feminino , Humanos , Artéria Ilíaca/anatomia & histologia , Imageamento Tridimensional , Masculino , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Medicine (Baltimore) ; 96(30): e7428, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28746184

RESUMO

We evaluated the effects of changes in blood flow due to abdominal aortic aneurysm (AAA) surgery by using a simple zero-dimension model and applied theoretical values to clinical data.The zero-dimension electronic circuit model and diagram of blood flow distribution were created by setting the resistance of the aorta, bilateral iliac arteries, renal arteries, and aneurysm. Resistance of the aneurysm and resistance of the aorta before surgery were compared with that of the aorta after surgery. We set the radius length of each anatomical parameter to calculate theoretical values.Renal flow increased 13.4% after surgery. Next, we analyzed contrast-enhanced computed tomography data of 59 patients who underwent AAA surgery. A total of 19 patients were treated with a Y graft and 7 patients were treated with a straight graft during open surgery. However, 33 patients were treated with a bifurcated stent graft. A significant linear relationship between the increased estimated glomerular filtration rate (eGFR) ratio and the decreased aneurysm ratio was found only for the straight graft group.Using a circuit model, renal blood flow theoretically increased after AAA surgery. Clinically, there was a correlation between volume regression and eGFR improvement only in the limited AAA group.


Assuntos
Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/cirurgia , Rim/fisiopatologia , Modelos Cardiovasculares , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Aorta/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular , Meios de Contraste , Eletricidade , Taxa de Filtração Glomerular/fisiologia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Modelos Lineares , Fluxo Sanguíneo Regional , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia , Estudos Retrospectivos , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Resistência Vascular
8.
Circ J ; 79(7): 1534-41, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25808227

RESUMO

BACKGROUND: Quantification of geometric changes of the stent graft (SG) in abdominal aortic aneurysm has been required for follow up of endovascular aneurysm repair (EVAR). The aim was to develop an image-based modeling system (V-Modeler) to investigate these changes over time. METHODS AND RESULTS: V-Modeler was applied to investigate the migration of the SG. Three sets of computed tomography images were taken at 3 different times: (1) 5 days after the implantation; (2) 7 months later when the unilateral leg migrated upward; and (3) 10 months later when the limb had migrated into the common iliac aneurysm resulting in a type 1b endoleak. A spline function was used to represent the center lines of the SG to track its evolutional geometric changes in a three-dimensional manner. The characteristics of vascular geometry, as well as the SG geometry using geometric parameters such as length, curvature, torsion, angle of tangent vector (ATV), and migrated length, was evaluated. It was observed that the strong peak of the curvature in the distal area appeared, and a conversion of the torsion disappeared chronologically. CONCLUSIONS: The V-Modeler was developed, which not only can extract vascular geometry but also can identify geometric parameter, such as curvature, torsion, and ATV, to predict adverse events following EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Modelos Cardiovasculares , Stents , Tomografia Computadorizada por Raios X , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/cirurgia , Aortografia , Feminino , Humanos , Fatores de Tempo
9.
J Am Heart Assoc ; 4(1): e001547, 2015 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-25600144

RESUMO

BACKGROUND: We aimed to develop a simple structural model of aortic aneurysms using computer-assisted drafting (CAD) in order to create a basis of definition for saccular aortic aneurysms. METHODS AND RESULTS: We constructed a simple aortic aneurysm model with 2 components: a tube similar to an aorta and an ellipse analogous to a bulging aneurysm. Three parameters, including the vertical and horizontal diameters of the ellipse and the fillet radius, were altered in the model. Using structural analysis with the finite element method, we visualized the distribution of the maximum principal stress (MPS) in the aortic wall and identified the area(s) of prominent stress. We then selected patients with thoracic aortic aneurysms in whom the aneurysm expansion rates were followed up and applied the theoretical results to the raw imaging data. The maximum MPS drastically increased at areas where the aspect ratio (vertical/horizontal) was <1, indicating that "horizontally long" hypothetical ellipses should be defined as "saccular" aneurysms. The aneurysm expansion rate for the patients with thoracic aneurysms conforming to these parameters was significantly high. Further, "vertically long" ellipses with a small fillet might be candidates for saccular aneurysms; however, the clinical data did not support this. CONCLUSIONS: Based on the biomechanical analysis of a simple aneurysm model and the clinical data of the thoracic aortic aneurysms, we defined "horizontally long" aortic aneurysms with an aspect ratio of <1 as "saccular" aneurysms.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Simulação por Computador , Imageamento Tridimensional , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Aneurisma/diagnóstico por imagem , Aneurisma/fisiopatologia , Aneurisma Roto/prevenção & controle , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Fenômenos Biomecânicos , Progressão da Doença , Humanos , Modelos Cardiovasculares , Monitorização Fisiológica , Variações Dependentes do Observador , Medição de Risco , Estudos de Amostragem , Estresse Mecânico
10.
Trop Med Health ; 41(4): 157-61, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24478593

RESUMO

Surveys of mosquito larvae were carried out in six areas of Kosrae Island, Kosrae State, the Federated States of Micronesia in December 2009 and June 2012. A total of 962 larvae of six species were collected from 106 natural and artificial habitats. They were identified as Aedes aegypti, Ae. albopictus, Ae. marshallensis, Culex quinquefasciatus, Cx. annulirostris, and Cx. kusaiensis. This is the first report from Kosrae Island for three of these species-Ae. marshallensis, Cx. quinquefasciatus, and Cx. annulirostris. The most abundant species was Ae. albopictus, followed by Ae. marshallensis, and these two species were found in all areas. Relatively large numbers of Cx. quinquefasciatus and Cx. kusaiensis were found in five areas. Fewer Cx. annulirostris were found, and only in three areas. Aedes aegypti larvae were collected from a single habitat at Tafunsak in 2009. To prevent the outbreak of dengue fever, environmental management should focus on the destruction, alteration, disposal and recycling of containers that produce larger numbers of adult Aedes mosquitoes.

11.
Traffic Inj Prev ; 4(4): 345-54, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14630583

RESUMO

In vehicle-pedestrian collisions, lower extremities of pedestrians are frequently injured by vehicle front structures. In this study, a finite element (FE) model of THUMS (total human model for safety) was modified in order to assess injuries to a pedestrian lower extremity. Dynamic impact responses of the knee joint of the FE model were validated on the basis of data from the literature. Since in real-world accidents, the vehicle bumper can impact the lower extremities in various situations, the relations between lower extremity injury risk and impact conditions, such as between impact location, angle, and impactor stiffness, were analyzed. The FE simulation demonstrated that the motion of the lower extremity may be classified into a contact effect of the impactor and an inertia effect from a thigh or leg. In the contact phase, the stress of the bone is high in the area contacted by the impactor, which can cause fracture. Thus, in this phase the impactor stiffness affects the fracture risk of bone. In the inertia phase, the behavior of the lower extremity depends on the impact locations and angles, and the knee ligament forces become high according to the lower extremity behavior. The force of the collateral ligament is high compared with other knee ligaments, due to knee valgus motions in vehicle-pedestrian collisions.


Assuntos
Acidentes de Trânsito , Automóveis , Traumatismos do Joelho/epidemiologia , Fenômenos Biomecânicos , Ligamentos Colaterais/lesões , Simulação por Computador , Desenho de Equipamento , Análise de Elementos Finitos , Fraturas Ósseas/fisiopatologia , Humanos , Articulação do Joelho/fisiopatologia , Traumatismos da Perna/fisiopatologia , Ligamento Colateral Médio do Joelho/lesões , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...