Eur J Radiol ; 118: 38-43, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31439256

RESUMO

PURPOSE: This study aimed to investigate whether a machine learning-based computed tomography (CT) texture analysis could predict the mutation status of V-Ki-ras2 Kirsten rat sarcoma viral oncogene homolog (KRAS) in colorectal cancer. METHOD: This retrospective study comprised 40 patients with pathologically confirmed colorectal cancer who underwent KRAS mutation testing, contrast-enhancement CT, and 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) before treatment. Of the 40 patients, 20 had mutated KRAS genes, whereas 20 had wild-type KRAS genes. Fourteen CT texture parameters were extracted from portal venous phase CT images of primary tumors, and the maximum standard uptake values (SUVmax) on 18F-FDG PET images were recorded. Univariate logistic regression was used to develop predictive models for each CT texture parameter and SUVmax, and a machine learning method (multivariate support vector machine) was used to develop a comprehensive set of CT texture parameters. The area under the receiver operating characteristic (ROC) curve (AUC) of each model was calculated using five-fold cross validation. In addition, the performance of the machine learning method with the CT texture parameters was compared with that of SUVmax. RESULTS: In the univariate analyses, the AUC of each CT texture parameter ranged from 0.4 to 0.7, while the AUC of the SUVmax was 0.58. Comparatively, the multivariate support vector machine with comprehensive CT texture parameters yielded an AUC of 0.82, indicating a superior prediction performance when compared to the SUVmax. CONCLUSIONS: A machine learning-based CT texture analysis was superior to the SUVmax for predicting the KRAS mutation status of a colorectal cancer.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Aprendizado de Máquina , Mutação/genética , Proteínas Proto-Oncogênicas p21(ras)/genética , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Neoplasias Colorretais/genética , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos
2.
Eur J Radiol ; 108: 7-12, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30396674

RESUMO

OBJECTIVE: To assess the utility of virtual monochromatic imaging (VMI) using a dual-layer spectral detector CT for electronic cleansing in fecal-tagging CT colonography (CTC). METHODS: This study included 35 patients who underwent fecal-tagging CTC with a dual-layer detector spectral CT scanner. Conventional images at 120 kVp and VMI at 40, 50, and 60 keV were reconstructed. Quantitative image quality parameters, i.e., tagging density and image noise, were compared and the visual image quality was scored on a four-point scale. We recorded the number of the colon segments with appropriate tagging density (≥300 HU) for each patient and used these data to compare the reconstructions. In addition, electronic cleansing performance was semi-quantitatively assessed using a four-point scale. RESULTS: The mean tagging density on VMI was significantly higher than that on conventional 120 kVp images. The number of colon segments with appropriate tagging density on VMI were significantly higher than that on conventional 120 kVp images. There was no significant difference among the reconstructed images with respect to image noise. Scores for subjective image quality and electronic cleansing performance on VMI were significantly higher than those on conventional 120 kVp images. CONCLUSION: With dual-layer spectral detector CT, VMI can yield significantly better fecal-tagged CTC image quality and improve electronic cleansing performance.


Assuntos
Colonografia Tomográfica Computadorizada/métodos , Fezes , Adulto , Idoso , Neoplasias do Colo/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos
3.
Acad Radiol ; 25(4): 415-422, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29191684

RESUMO

RATIONALE AND OBJECTIVES: To assess the effect of model-based iterative reconstruction (MBIR) on image quality and diagnostic performance of low-radiation-dose computed tomography colonography (CTC) in the preoperative assessment of colorectal cancer. MATERIALS AND METHODS: This study included 30 patients with colorectal cancer referred for surgical treatment. All patients underwent CTC with a standard dose (SD) protocol in the supine position and a low-dose (LD; radiation dose reduction of approximately 85%) protocol in the prone position. The SD protocol images were post-processed using filtered back projection (FBP), whereas the LD protocol images were post-processed using FBP and MBIR. Objective and subjective image quality parameters were compared among the three different methods. Preoperative evaluations, including site, length, and tumor and node staging were performed, and the findings were compared to the postsurgical findings. RESULTS: The mean image noise of SD-FBP, LD-FBP, and LD-MBIR images was 17.3 ± 3.2, 40.5 ± 10.9, and 11.2 ± 2.0 Hounsfield units, respectively. There were significant differences for all comparison combinations among the three methods (P < .01). For image noise, the mean visual scores were significantly higher for SD-FBP and LD-MBIR than for LD-FBP, and the scores for SD-FBP and LD-MBIR were equivalent (3.9 ± 0.3 [SD-FBP], 2.0 ± 0.5 [LD-FBP], and 3.7 ± 0.3 [LD-MBIR]). Preoperative information was more accurate under SD-FBP and LD-MBIR than under LD-FBP, and the information was comparable between SD-FBP and LD-MBIR. CONCLUSION: MBIR can yield significantly improved image quality on low-radiation-dose CTC and provide preoperative information equivalent to that of standard-radiation-dose protocol.


Assuntos
Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Posicionamento do Paciente , Período Pré-Operatório , Decúbito Ventral , Doses de Radiação , Razão Sinal-Ruído , Decúbito Dorsal , Carga Tumoral
4.
Eur Radiol ; 27(2): 812-820, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27240454

RESUMO

OBJECTIVES: We evaluated the effects of a low contrast material (CM) dose protocol using 80-kVp on the image quality of hepatic multiphasic CT scans acquired on a 320-row CT scanner. METHODS: We scanned 30 patients with renal insufficiency (eGFR < 45 mL/min/1.73 m2) using 80-kVp and a CM dose of 300mgI/kg. Another 30 patients without renal insufficiency (eGFR > 60 mL/min/1.73 m2) were scanned with the conventional 120-kVp protocol and the standard CM dose of 600mgI/kg. Quantitative image quality parameters, i.e. CT attenuation, image noise, and the contrast-to-noise ratio (CNR) were compared and the visual image quality was scored on a four-point scale. The volume CT dose index (CTDIvol) and the size-specific dose estimate (SSDE) recorded with the 80- and the 120-kVp protocols were also compared. RESULTS: Image noise and contrast enhancement were equivalent for the two protocols. There was no significant difference in the CNR of all anatomic sites and in the visual scores for overall image quality. The CTDIvol and SSDE were approximately 25-30 % lower under the 80-kVp protocol. CONCLUSION: Hepatic multiphase CT using 80-kVp on a 320-row CT scanner allowed for a decrease in the CM dose and a reduction in the radiation dose without image quality degradation in patients with renal insufficiency. KEY POINTS: • The 80-kVp CT protocol enabled reduction of contrast dose by 50 % • The 80-kVp CT protocol reduced the radiation dose by 25-33 % • There was no degradation in the image quality of the 80-kVp protocol.


Assuntos
Injúria Renal Aguda/prevenção & controle , Meios de Contraste/administração & dosagem , Fígado/diagnóstico por imagem , Doses de Radiação , Insuficiência Renal , Tomografia Computadorizada por Raios X/métodos , Injúria Renal Aguda/induzido quimicamente , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Meios de Contraste/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
5.
Acad Radiol ; 23(2): 155-62, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25872861

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to assess the effect of a low-tube-voltage technique and iterative reconstruction (IR) on the radiation dose and image quality of computed tomography colonography (CTC). MATERIALS AND METHODS: We studied 30 patients (14 women and 16 men; mean age, 64.5 ± 13.1 years; range, 39-90 years) with colorectal cancer referred for surgical treatment. All underwent CTC with fecal tagging under a standard 120-kVp protocol in the supine position and a 100-kVp protocol in the prone position. The 120-kVp images were reconstructed with filtered back projection (FBP). The 100-kVp images were postprocessed using FBP and a hybrid type of IR (adaptive iterative dose reduction 3D). The effective radiation dose (ED), image noise, and contrast-to-noise ratio (CNR) were compared among the three protocols. The visual image quality was scored on a four-point scale. RESULTS: The mean ED was significantly lower under the 100-kVp protocol than the 120-kVp protocol, resulting in a 27% radiation dose decrease (3.5 ± 2.0 vs 2.5 ± 1.5 mSv; P < .01). Image noise decreased by 48%, and the mean attenuation of tagged fluid increased from 452 to 558 HU on images acquired at 100 kVp with IR compared to that in the 120-kVp protocol; these differences were significant. The mean CNR was significantly higher under the 100 kVp with IR than the other two protocols. We found no significant differences in the visual scores for diagnostic utility between the 100 kVp with IR and the 120 kVp with FBP protocol (P = .10). CONCLUSIONS: Low-tube-voltage CTC reduced the radiation dose by approximately 27% while maintaining the image quality.


Assuntos
Colonografia Tomográfica Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Colonografia Tomográfica Computadorizada/instrumentação , Neoplasias Colorretais/diagnóstico por imagem , Meios de Contraste , Diatrizoato , Diatrizoato de Meglumina , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Posicionamento do Paciente , Decúbito Ventral , Estudos Prospectivos , Razão Sinal-Ruído , Decúbito Dorsal
6.
Kurume Med J ; 61(1-2): 9-15, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25400236

RESUMO

Sufficient colonic dilation is important when using CT colonography (CTC) for colorectal cancer screening. We investigated the effect of antispasmodic agents and the patient body habitus on the degree of colonic dilation in screening CTC.We assessed the effect of clinical characteristics [age, gender, body mass index (BMI), and the presence of diverticula] and the use of antispasmodics on colonic distention in 140 patients who underwent CTC for colorectal cancer screening. The CTC was performed in both the supine- and prone positions. Seventy patients received antispasmodics prior to CT examination and the other 70 did not. Colonic distention was scored using a 5-point scale: 1=collapsed, 2=poorly visualized, 3=visualized but underdistended, 4=acceptable, and 5=excellent. Images scored as 4 or 5 were considered to be of diagnostic quality. The mean visual evaluation score was significantly higher in the supine- than the prone position (4.2±0.5 vs. 4.0±0.5, p<0.01). For the supine position, only the use of antispasmodic was statistically associated with sufficient colonic dilation by univariate logistic analysis (odds ratio=2.365, p=0.03). For the prone position, age, BMI, and the use of antispasmodic were statistically associated with sufficient colonic dilation by multivariate analysis. The odds ratio of these parameters was 0.955 (p=0.02), 0.874 (p=0.03), and 2.391 (p=0.02), respectively.We obtained sufficient colonic dilation with an antispasmodic for CTC in both positions. Younger age and a lower BMI were also associated with better colonic dilation in the prone position.


Assuntos
Índice de Massa Corporal , Colo/efeitos dos fármacos , Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Parassimpatolíticos , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Japão , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Parassimpatolíticos/administração & dosagem , Posicionamento do Paciente , Valor Preditivo dos Testes , Decúbito Ventral , Estudos Prospectivos , Fatores Sexuais , Decúbito Dorsal
7.
J Comput Assist Tomogr ; 37(5): 790-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24045258

RESUMO

OBJECTIVE: The objective of this study was to evaluate the effect of a low-tube-voltage technique and hybrid iterative reconstruction (HIR) on image quality at dynamic computed tomography (CT) of the pancreas. METHODS: The study included 18 consecutive patients (10 women, 8 men; mean age, 68.5 ± 9.5 years) with locally advanced pancreatic cancer who received chemotherapy and had stable disease during the 100- and 120-kV CT studies. The 120-kV images were reconstructed using filtered back projection, and the 100-kV images were postprocessed using filtered back projection and HIR. Scans obtained during 3 pancreatic phases were subjected to quantitative and qualitative analysis. RESULTS: The mean effective dose was significantly lower under the 100- than the 120-kV protocols (29.2 ± 3.6 vs 52.1 ± 5.1 mSv; P < 0.01). The mean contrast-to-noise ratio of the pancreatic cancer and the visual scores were significantly higher under 100 kV with HIR than those under the other 2 protocols (P < 0.01). CONCLUSIONS: Use of low tube voltage and HIR can provide significantly improved image quality at pancreatic dynamic CT.


Assuntos
Algoritmos , Neoplasias Pancreáticas/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Acta Radiol ; 53(7): 714-9, 2012 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-22821957

RESUMO

BACKGROUND: Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. PURPOSE: To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. MATERIAL AND METHODS: We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. RESULTS: Detection sensitivity for flat polyps was 31.3%, 44.4%, and 87.5% for lesions measuring 2-3 mm, 4-5 mm, and ≥6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6%, 79.0%, and 91.7%. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. CONCLUSION: CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Adulto , Idoso , Biópsia , Catárticos/administração & dosagem , Distribuição de Qui-Quadrado , Pólipos do Colo/patologia , Colonoscopia , Meios de Contraste/administração & dosagem , Diatrizoato de Meglumina/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polietilenoglicóis/administração & dosagem , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
Anticancer Res ; 31(9): 2983-8, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21868548

RESUMO

AIM: To determine the safety and usefulness of a novel anticancer drug, miriplatin, in transarterial chemoembolization (TACE) for unresectable hepatocellular carcinoma. PATIENTS AND METHODS: Patients (n=115) who underwent TACE with miriplatin-lipiodol suspension (miriplatin group), and control patients (n=131) who underwent TACE with cisplatin-lipiodol suspension (CDDP group) took part in this study. RESULTS: The overall incidence of adverse events was significantly lower in the miriplatin group. The percentage of patients attaining treatment effect 4 in both groups was not significantly different. The proportion exhibiting a >50% decrease in positive tumor markers following TACE was significantly greater in the CDDP group for alpha-fetoprotein, but not significantly different for des-gammma-carboxy prothrombin. CONCLUSION: Miriplatin-lipiodol suspension was associated with reduced intensity of adverse events and had comparable short-term therapeutic effects to cisplatin-lipiodol suspension, thereby indicating its usefulness in TACE.


Assuntos
Antineoplásicos/uso terapêutico , Carcinoma Hepatocelular/tratamento farmacológico , Quimioembolização Terapêutica , Óleo Etiodado/uso terapêutico , Neoplasias Hepáticas/tratamento farmacológico , Compostos Organoplatínicos/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/administração & dosagem , Antineoplásicos/efeitos adversos , Óleo Etiodado/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organoplatínicos/administração & dosagem , Compostos Organoplatínicos/efeitos adversos