1.
J Bone Joint Surg Br ; 84(4): 561-5, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12043779

RESUMO

The Bisurface knee prosthesis (BP) has a posterior stabilising cam (ball-and-socket joint) in the mid-posterior region of the femorotibial joint in an attempt to improve the range of movement. Based on an in vitro weight-bearing study contact areas of the Insall/Burstein 2 (IB2) and the BP knee were compared using pressure-sensitive films. The stability afforded by the cam was evaluated by means of dislocation distances in the vertical and horizontal planes. Significant adverse anterior translation in mid-flexion was not observed with the BP knee since the cam was effective above 60 degrees of flexion. At flexion of 60 degrees or more, the total contact areas were larger, as the cam represented a weight-bearing surface. The dislocation distances for the BP knee compared favourably with those for the IB2 knee. We conclude that the cam of the BP knee allows good movement, stability and wear.


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Humanos , Pessoa de Meia-Idade , Desenho de Prótese
2.
Altern Ther Health Med ; 7(5): 54-64, 66-9, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11565402

RESUMO

CONTEXT: Noninvasive magnetotherapeutic approaches to bone healing have been successful in past clinical studies. OBJECTIVE: To determine the effectiveness of low-amplitude, extremely low frequency magnetic fields on patients with knee pain due to osteoarthritis. DESIGN: Placebo-controlled, randomized, double-blind clinical study. SETTING: 4 outpatient clinics. PARTICIPANTS: 176 patients were randomly assigned to 1 of 2 groups, the placebo group (magnet off) or the active group (magnet on). INTERVENTION: 6-minute exposure to each magnetic field signal using 8 exposure sessions for each treatment session, the number of treatment sessions totaling 8 during a 2-week period, yielded patients being exposed to uniform magnetic fields for 48 minutes per treatment session 8 times in 2 weeks. The magnetic fields used in this study were generated by a Jacobson Resonator, which consists of two 18-inch diameter (46-cm diameter) coils connected in series, in turn connected to a function generator via an attenuator to obtain the specific amplitude and frequency. The range of magnetic field amplitudes used was from 2.74 x 10(-7) to 3.4 x 10(-8) G, with corresponding frequencies of 7.7 to 0.976 Hz. OUTCOME MEASURES: Each subject rated his or her pain level from 1 (minimal) to 10 (maximal) before and after each treatment and 2 weeks after treatment. Subjects also recorded their pain intensity in a diary while outside the treatment environment for 2 weeks after the last treatment session (session 8) twice daily: upon awakening (within 15 minutes) and upon retiring (just before going to bed at night). RESULTS: Reduction in pain after a treatment session was significantly (P < .001) greater in the magnet-on group (46%) compared to the magnet-off group (8%). CONCLUSION: Low-amplitude, extremely low frequency magnetic fields are safe and effective for treating patients with chronic knee pain due to osteoarthritis.


Assuntos
Campos Eletromagnéticos , Magnetismo/uso terapêutico , Osteoartrite do Joelho/terapia , Adulto , Método Duplo-Cego , Feminino , Humanos , Masculino , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/fisiopatologia , Dor/etiologia , Dor/fisiopatologia , Manejo da Dor , Medição da Dor/métodos , Medição da Dor/estatística & dados numéricos
3.
Pacing Clin Electrophysiol ; 24(12): 1765-73, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11817810

RESUMO

The 7 Fr "split-tip electrode" (2.5-mm tip electrode divided longitudinally into four electrodes with an adjacent 2-mm ring electrode) improves mapping resolution due to its small recording electrodes and narrow interelectrode distances (0.1 mm). The purpose of this study was to examine the temperature-controlled ablation properties of this electrode. In seven anesthetized dogs, the thigh muscles were exposed and superfused with canine blood. A split-tip catheter electrode (with a thermocouple in each of the five electrodes) and a conventional 4-mm catheter electrode were positioned at constant pressure perpendicular or parallel to the surface of the thigh muscle. Impedance measured between each split electrode and a skin patch correlated with the degree of contact with blood and tissue. In the parallel catheter to tissue orientation, split electrodes not in contact with tissue had a low impedance (mean 210-224 ohms), and the split electrode almost entirely in contact with tissue had the highest impedance (380 +/- 56 ohms). In the perpendicular catheter to tissue orientation all split electrodes had a similar impedance (mean 279-286 ohms). A total of 75 radiofrequency (RF) lesions were produced in the temperature-controlled mode with the 4-mm electrode (target 60 degrees C) or the split-tip electrode (power limited by the hottest electrode reaching 70 degrees C) with current delivered to all five electrodes simultaneously, or only to electrodes in contact with tissue. Lesion depth was not significantly different between electrodes in the parallel orientation (5.2 +/- 0.9 vs 5.1 +/- 1.4 vs 5.3 +/- 1.1 mm), but significantly deeper with the conventional 4-mm tip electrode in the perpendicular orientation (6.7 +/- 1.2 vs 5.3 +/- 1.3 vs 5.6 +/- 0.9 mm, P < 0.05). This was due to higher power delivered to the conventional 4-mm electrode (27 +/- 9 vs 17 +/- 7 vs 15 +/- 7 W, P < 0.05) because convective cooling by the blood flow was less effective for the split-tip electrode due to a reduced heat conduction across the interelectrode space from the hottest electrode to cooler areas of the group of five electrodes (mean temperature difference between the hottest split electrodes and the ring electrode: 24 degrees C). Electrode cooling or heat conduction was not effected by the elimination of current delivery to non-contact electrodes. Steam pops occurred in 36% of applications with the conventional 4-mm electrode in the perpendicular orientation but never with the split-tip electrode in spite of the higher target temperature. Measurement of impedance from the split electrodes allow the determination of electrode tissue contact and RF lesions produced with the split-tip electrode in the temperature-controlled mode using a target of 70 degrees C were of reasonable size and not associated with steam pops.


Assuntos
Ablação por Cateter , Animais , Ablação por Cateter/instrumentação , Cães , Impedância Elétrica , Eletrodos , Desenho de Equipamento , Músculo Esquelético , Temperatura
4.
J Interv Card Electrophysiol ; 4(1): 219-24, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10729837

RESUMO

We previously showed that parasympathetic stimulation by a basket electrode catheter (BEC) positioned in the superior vena cava (SVC) can slow sinus rate (SR) or ventricular response (VR) during atrial fibrillation (AF). In 11 dogs, anesthetized with Na-pentobarbital, standard ECG leads II and aVR, blood pressure and right atrial electrograms were continuously monitored. Two different BEC configurations (B1, B2) were tested in the SVC. B1 consisted of five metal splines, each 3 cm in length. Stimulation was applied between adjacent splines. B2 consisted of 2 electrodes at opposite ends of each of 5 splines and a larger electrode at the middle of each spline. Stimulation was delivered between the two end electrodes and the middle electrode on the same arm. Stimulation consisted of square wave stimuli, each 0.1 msec duration, frequency 20 Hz at voltages from 1-40 V. Six dogs were studied with B1 and five were studied with the B2 configuration. The average voltage required to produce a 50% decrease in heart rate was 22+/- 12 V when stimulating between adjacent splines (B1) compared to 10+/- 5 V when stimulating along a single spline (B2), a 55% decrease (p

Assuntos
Fibrilação Atrial/fisiopatologia , Cateterismo , Estimulação Elétrica , Frequência Cardíaca , Coração/inervação , Sistema Nervoso Parassimpático/fisiologia , Animais , Cães , Desenho de Equipamento , Humanos , Recém-Nascido , Veia Cava Superior
5.
Circulation ; 98(5): 458-65, 1998 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-9714097

RESUMO

BACKGROUND: Clinical efficacy has driven the use of larger electrodes (7F, length > or =4 mm) for radiofrequency ablation, which reduces electrogram resolution and causes variability in tissue contact depending on electrode orientation. With active cooling, ablation electrode size may be reduced. The purpose of this study was to examine the effect of electrode length on tissue temperature and lesion size with saline irrigation used for active cooling. METHODS AND RESULTS: In 11 anesthetized dogs, the thigh muscle was exposed and bathed with heparinized canine blood. A 7F ablation catheter with a 2- or 5-mm irrigated tip electrode was positioned perpendicular or parallel to the thigh muscle. Radiofrequency current was delivered at constant voltage (50 V) for 30 seconds during saline irrigation (20 mL/min) to 148 sites. Tissue temperature at depths of 3.5 and 7 mm and lesion size were measured. In the perpendicular electrode-tissue orientation, radiofrequency applications at 50 V with the 2-mm electrode compared with the 5-mm electrode resulted in lower power at 50 V (26 versus 36 W) but higher tissue temperatures, larger lesion depth (8.0 versus 5.4 mm), and greater diameter (12.4 mm versus 8.4 mm). Also, in the parallel orientation, overall power was lower with the 2-mm electrode (25 versus 33 W), but tissue temperatures were higher and lesions were deeper (7.3 versus 6.9 mm). Lesion diameter was similar (11.1 versus 11.3 mm) for both electrodes. CONCLUSIONS: The smaller electrode resulted in transmission of a greater fraction of the radiofrequency power to the tissue and resulted in higher tissue temperature, larger lesions, and lower dependency of lesion size on the electrode orientation.


Assuntos
Ablação por Cateter/instrumentação , Animais , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Distribuição de Qui-Quadrado , Cães , Eletrodos/estatística & dados numéricos , Desenho de Equipamento , Estudos de Avaliação como Assunto , Músculos/patologia , Músculos/cirurgia , Temperatura , Coxa da Perna
6.
J Cardiovasc Electrophysiol ; 9(1): 47-54, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9475577

RESUMO

INTRODUCTION: Increasing electrode size allows an increase in radiofrequency lesion depth. The purpose of this study was to examine the roles of added electrode cooling and electrode-tissue interface area in producing deeper lesions. METHODS AND RESULTS: In 10 dogs, the thigh muscle was exposed and superfused with heparinized blood. An 8-French catheter with 4- or 8-mm tip electrode was positioned against the muscle with a blood flow of 350 mL/min directed around the electrode. Radiofrequency current was delivered using four methods: (1) electrode perpendicular to the muscle, using variable voltage to maintain the electrode-tissue interface temperature at 60 degrees C; (2) same except the surrounding blood was stationary; (3) perpendicular electrode position, maintaining tissue temperature (3.5-mm depth) at 90 degrees C; and (4) electrode parallel to the muscle, maintaining tissue temperature at 90 degrees C. Electrode-tissue interface temperature, tissue temperature (3.5- and 7.0-mm depths), and lesion size were compared between the 4- and 8-mm electrodes in each method. In Methods 1 and 2, the tissue temperatures and lesion depth were greater with the 8-mm electrode. These differences were smaller without blood flow, suggesting the improved convective cooling of the larger electrode resulted in greater power delivered to the tissue at the same electrode-tissue interface temperature. In Method 3 (same tissue current density), the electrode-tissue interface temperature was significantly lower with the 8-mm electrode. With parallel orientation and same tissue temperature at 3.5-mm depth (Method 4), the tissue temperature at 7.0-mm depth and lesion depth were greater with the 8-mm electrode, suggesting increased conductive heating due to larger volume of resistive heating because of the larger electrode-tissue interface area. CONCLUSION: With a larger electrode, both increased cooling and increased electrode-tissue interface area increase volume of resistive heating and lesion depth.


Assuntos
Ablação por Cateter/instrumentação , Eletrodos , Animais , Ablação por Cateter/métodos , Cães , Músculo Esquelético/cirurgia , Ondas de Rádio , Temperatura , Coxa da Perna/cirurgia
7.
Circulation ; 93(6): 1083-6, 1996 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-8653827

RESUMO

BACKGROUND: Progression of unintentionally induced atrioventricular delay is occasionally observed directly after termination of radiofrequency delivery in the vicinity of the atrioventricular node. We postulated that the application of a radiofrequency pulse may result in a tissue temperature rise that continues after the pulse. METHODS AND RESULTS: Using the thigh muscle preparation, 5-, 10-, 20-, and 30-second pulses were applied as 30 to 40 W via a standard 4-mm tip electrode with 10-g contact pressure. Forty-one undisturbed pulses were delivered while recording intramural temperatures at 2-, 4-, and 7-mm depth. Maximal "thermal latency" was observed with the shortest pulse duration and at greatest depth. With 5-second applications, tissue temperature at 7-mm depth peaked 11.6 seconds after termination of radiofrequency delivery and stayed above end-of-pulse value as long as 34.5 seconds after the pulse. The additional rise in tissue temperature was 2.9 degrees C. If only recording within the lesion border zone were considered, the duration of latency was maximal with 10-second pulses: an additional gain in tissue temperature of 3.4 degrees C was observed 6.4 seconds after the pulse while tissue temperature stayed above end-of-pulse value during 18.3 seconds. CONCLUSIONS: With relatively short applications, tissue temperature continues to rise after termination of radiofrequency delivery. This "thermal latency" may result in lesion growth after the pulse and may so explain the incidentally observed progression of conduction block after short pulses in the vicinity of the atrioventricular node. It also may explain the apparent discrepancy between lesion growth rate and intramural temperature rise studies.


Assuntos
Ablação por Cateter , Animais , Temperatura Corporal , Cães , Tempo de Reação
8.
Panminerva Med ; 37(2): 98-104, 1995 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8637778

RESUMO

The clinical studies describing the treatment of some neurological disorders with an externally applied pico Tesla (10R Tesla, or 10(-8) gauss) magnetic field are considered from a physical view point. An equation relating the intrinsic or "rest" energy of a charged particle of mass with its energy of interaction in an externally applied magnetic field B is presented. The equation is proposed to represent an initial basic physical interaction as a part of a more complex biological mechanism to explain the therapeutic effects of externally applied magnetic fields in these and other neurologic disorders.


Assuntos
Magnetismo , Doenças do Sistema Nervoso/terapia , Humanos , Computação Matemática
9.
Circulation ; 91(8): 2264-73, 1995 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-7697856

RESUMO

BACKGROUND: It is thought that only a thin layer of tissue adjacent to the electrode is heated directly by electrical current (resistive heating) during radiofrequency ablation. Most of the thermal injury is thought to result from conduction of heat from the surface layer. The purpose of this study was to determine whether lesion depth could be increased by producing direct resistive heating deeper in the tissue with higher radiofrequency power, allowed by cooling the ablation electrode with saline irrigation to prevent the rise in impedance that occurs when the electrode-tissue interface temperature reaches 100 degrees C. METHODS AND RESULTS: In 11 anesthetized dogs, the thigh muscle was exposed and bathed with heparinized canine blood (36 degrees C to 37 degrees C). A 7F catheter, with a central lumen, a 5-mm tip electrode with six irrigation holes, and an internal thermistor, was positioned perpendicular to the thigh muscle and held at a constant contact weight of 10 g. Radiofrequency current was delivered to 145 sites (1) at high constant voltage (66 V) without irrigation (CV group, n = 31), (2) at variable voltage (20 to 66 V) to maintain tip-electrode temperature at 80 degrees C to 90 degrees C without irrigation (temperature-control group, n = 39), and (3) at high CV (66 V) with saline irrigation through the catheter lumen and ablation electrode at 20 mL/min (CV irrigation group, n = 75). Radiofrequency current was applied for 60 seconds but was terminated immediately in the event of an impedance rise > or = 10 omega. Tip-electrode temperature and tissue temperature at depths of 3.5 and 7.0 mm were measured in all three groups (n = 145). In 33 CV irrigation group applications, temperature was also measured with a separate probe at the center (n = 18) or edge (n = 15) of the electrode-tissue interface. In all 31 CV group applications, radiofrequency energy delivery was terminated prematurely (at 11.6 +/- 4.8 seconds) owing to an impedance rise associated with an electrode temperature of 98.8 +/- 2.1 degrees C. All 39 temperature-control applications were delivered for 60 seconds without an impedance rise, but voltage had to be reduced to 38.4 +/- 6.1 V to avoid temperatures > 90 degrees C (mean tip-electrode temperature, 84.5 +/- 1.4 degrees C). In CV irrigation applications, the tip-electrode temperature was not > 48 degrees C (mean, 38.4 +/- 5.1 degrees C) and the electrode-tissue interface temperature was not > 80 degrees C (mean, 69.4 +/- 5.7 degrees C). An abrupt impedance rise with an audible pop and without coagulum occurred in 6 of 75 CV irrigation group applications at 30 to 51 seconds, probably owing to release of steam from below the surface. In the CV and temperature-control group applications, the temperatures at depths of 3.5 (62.1 +/- 15.1 degrees C and 67.9 +/- 7.5 degrees C) and 7.0 mm (40.3 +/- 5.3 degrees C and 48.3 +/- 4.8 degrees C) were always lower than the electrode temperature. Conversely, in CV irrigation group applications, electrode and electrode-tissue interface temperatures were consistently exceeded by the tissue temperature at depths of 3.5 mm (94.7 +/- 9.1 degrees C) and occasionally 7.0 mm (65.1 +/- 9.7 degrees C). Lesion dimensions were smallest in CV group applications (depth, 4.7 +/- 0.6 mm; maximal diameter, 9.8 +/- 0.8 mm; volume, 135 +/- 33 mm3), intermediate in temperature-control group applications (depth, 6.1 +/- 0.5 mm; maximal diameter, 11.3 +/- 0.9 mm; volume, 275 +/- 55 mm3), and largest in CV irrigation group applications (depth, 9.9 +/- 1.1 mm; maximal diameter, 14.3 +/- 1.5 mm; volume, 700 +/- 217 mm3; P < .01, respectively). CONCLUSIONS: Saline irrigation maintains a low electrode-tissue interface temperature during radiofrequency application at high power, which prevents an impedance rise and produces deeper and larger lesions. A higher temperature in the tissue (3.5 mm deep) than at the electrode-tissue interface indicates that direct resistive heating occurred deeper


Assuntos
Ablação por Cateter/instrumentação , Músculo Esquelético/fisiologia , Músculo Esquelético/cirurgia , Animais , Temperatura Corporal , Ablação por Cateter/métodos , Cães , Impedância Elétrica , Eletrodos , Sistema de Condução Cardíaco/cirurgia , Membro Posterior , Cloreto de Sódio , Taquicardia Ventricular/cirurgia , Irrigação Terapêutica , Fatores de Tempo
10.
Neurol Res ; 17(2): 144-8, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7609852

RESUMO

The recent clinical studies describing the treatment of some neurological disorders with an externally applied pico Tesla (10(-12) Tesla, or 10(-8) gauss) magnetic field are considered from a physical view point. An equation relating the intrinsic (or rest) energy of a charged particle of mass m with its energy of interaction in an externally applied magnetic field B is presented. The equation represents an initial basic physical interaction as a part of a more complex biological mechanism to explain the therapeutic effects of externally applied magnetic fields in these and other neurologic disorders.


Assuntos
Encefalopatias/terapia , Magnetismo/uso terapêutico , Epilepsia/terapia , Humanos , Magnetoencefalografia/métodos , Doença de Parkinson/terapia
11.
Neurosurgery ; 35(4): 785-7; discussion 787-8, 1994 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7808631

RESUMO

A new cautery system known as the electroconvergent cautery system is described. This cautery system uses a radiofrequency current of 13.56 MHz. The current is passed through an amplifier, an impedance matching system, and a loading and tuning coil into a probe. After the probe tip is touched to the tissue, the mismatch of impedance between the probe tip and the generator is minimized to almost zero, resulting in high-current density at the probe tip, which causes pinpoint heating of the tissue at the point where it is touched by the probe without spread of heat to the surrounding tissue. This heat can cut and vaporize tissue and coagulate vessels. The probe can also be used to coagulate vessels with standard surgical forceps. Because convergence of energy is used for tissue heating, a grounding pad is not needed. The system can also be used under cerebrospinal fluid or saline.


Assuntos
Neoplasias Encefálicas/cirurgia , Eletrocoagulação/instrumentação , Astrocitoma/cirurgia , Neoplasias Encefálicas/secundário , Aprovação de Equipamentos , Desenho de Equipamento , Lobo Frontal/cirurgia , Glioma/cirurgia , Hemostasia Cirúrgica/instrumentação , Humanos , Imageamento por Ressonância Magnética , Pinealoma/cirurgia , Teratoma/cirurgia
12.
Am J Surg ; 168(1): 19-21, 1994 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8024093

RESUMO

In this follow-up report of the treatment of primary breast cancer with adjuvant immunotherapy, a total of 95 patients were studied: 46 patients with stage I breast cancer and 49 patients with stage II breast cancer. All patients underwent standard surgical treatment and received immunotherapy as adjuvant treatment. Patients received a primary series of eight doses (1 mL of tumor-associated antigen preparation given as 0.2 mL intradermally and 0.8 mL subcutaneously) given over 8 weeks, and then booster injections every 3 months for at least 2 years. The 5-year survival with adjuvant immunotherapy was 83% for those with negative axillary nodes and 53% for those with positive nodes; this compares favorably with national 5-year survival statistics from two other studies (node-negative, 72% and 83%; node-positive, 51% and 59%). Based on these data, the addition of immunotherapy to other adjuvant therapies in randomized prospective trials seems both reasonable and justified.


Assuntos
Adjuvantes Imunológicos/uso terapêutico , Antígenos de Neoplasias/imunologia , Neoplasias da Mama/mortalidade , Neoplasias da Mama/cirurgia , Análise Atuarial , Adulto , Distribuição por Idade , Idoso , Antineoplásicos/uso terapêutico , Neoplasias da Mama/imunologia , Neoplasias da Mama/patologia , Estudos de Casos e Controles , Quimioterapia Adjuvante , Terapia Combinada , Feminino , Seguimentos , Humanos , Imunização Secundária , Injeções Intradérmicas , Injeções Subcutâneas , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Taxa de Sobrevida
13.
Neurosurgery ; 35(1): 163-6; discussion 166-7, 1994 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7936142

RESUMO

The electromagnetic field focusing (EFF) surgical instrument creates an oscillating electromagnetic field that induces eddy currents in the tissue, which converge at the point of contact. This energy creates a focal spark capable of vaporizing tissue. The EFF instrument was used to resect 17 meningiomas in 14 patients. The effectiveness of the EFF probe in resecting tumor tissue was compared with that of the Cavetron ultrasonic surgical aspirator (Model 100) in 11 patients. The EFF system was superior to the Cavetron ultrasonic surgical aspirator in tumor excision in all but two cases, in which the EFF grounding tip was poorly tuned. Surgical time and blood loss were reduced by subjective analysis in all but these two cases, especially in the rubbery or calcified meningiomas resistant to aspiration. No complications were directly attributable to use of the EFF. Drawbacks encountered with the EFF system include buildup of "char" on the tip, requiring scraping, and intense heat at the tip, which occasionally melted the insulating sheath, requiring replacement.


Assuntos
Campos Eletromagnéticos , Eletrocirurgia/instrumentação , Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Physiol Chem Phys Med NMR ; 26(4): 287-97, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7700979

RESUMO

The clinical studies describing the treatment of some neurological disorders with an externally applied pico Tesla (10(-12) Tesla, or 10(-8) gauss) magnetic field are considered from a physical view point. An equation relating the intrinsic (or "rest") energy of a charted particle of mass m with its energy of interaction in an externally applied magnetic field B is presented. The equation is proposed to represent an initial basic physical interaction as a part of a more complex biological mechanism to explain the therapeutic effects of externally applied magnetic fields in these and other neurologic disorders.


Assuntos
Campos Eletromagnéticos , Doenças do Sistema Nervoso/terapia , Humanos
15.
J Laparoendosc Surg ; 2(6): 293-302, 1992 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-1489994

RESUMO

The initial 950 consecutive laparoscopic cholecystectomies performed in one city at four hospitals by 30 general surgeons are reported, covering a period from April 4, 1990 to April 3, 1991. There were two operative deaths (0.2%), three common bile duct lacerations (0.3%), two subhepatic abscesses, two bowel perforations, and three bile leaks, two requiring laparotomy. Seven episodes of bleeding occurred, of which five required laparotomy, but none involved a major vessel. Sixty-five procedures were converted to open (6.7%). The mean operative time was 85.4 min. Intraoperative cholangiography was adequately completed in 49.8% and not attempted in 30.3%. Thirteen patients (2.7%) were found to have common duct stones. The pathologic diagnoses were chronic cholecystitis in 784 patients (82.5%), acute cholecystitis in 145 (15.3%), and cancer of the gallbladder in one (0.1%). Hospital stays ranged from 4 h to 31 days (mean 49.5 h). This procedure can be learned and performed safely in a community setting.


Assuntos
Colecistectomia Laparoscópica , Fatores Etários , Peso Corporal , Causas de Morte , Colecistectomia/mortalidade , Colecistectomia/estatística & dados numéricos , Colecistectomia Laparoscópica/efeitos adversos , Colecistectomia Laparoscópica/métodos , Colecistectomia Laparoscópica/mortalidade , Colecistectomia Laparoscópica/estatística & dados numéricos , Feminino , Humanos , Complicações Intraoperatórias/epidemiologia , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Oklahoma/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Tempo
16.
Biomed Instrum Technol ; 26(5): 414-21, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1393211

RESUMO

Electromagnetic-field focusing (EFF) is a method of converging induced eddy current onto a pointed tip of a tuned length return circuit in the near field of a resonator, which results in the production of high temperature. Previously reported applications of this method include various devices for local hyperthermia and a precision surgical device. The latter is currently being used in human clinical trials under two investigational device exemptions from the Food and Drug Administration. In the present work, the thermal profile produced in a uniform, tissue-simulating phantom by the hand-held probe of the surgical EFF system is compared with those produced by mono- and bipolar electrocauteries and by a contact Nd:YAG laser. At the equivalent power setting and 2-cm insertion depth, the EFF probe was shown to have a tighter thermal profile than the monopolar electrocautery or the contact Nd:YAG laser. This finding is consistent with earlier histologic evidence that brain cortical tissue cut by the surgical EFF probe had minimal thermal damage in the tissue surrounding the incision.


Assuntos
Eletrocoagulação , Campos Eletromagnéticos , Hipertermia Induzida/instrumentação , Terapia a Laser , Temperatura , Desenho de Equipamento , Modelos Estruturais
17.
J Hosp Infect ; 21(1): 39-50, 1992 May.
Artigo em Inglês | MEDLINE | ID: mdl-1351495

RESUMO

The aerosol of surgical plume could be measured effectively with the use of bacteriophage phi X-174 as a biological marker, in contrast to previous methodologies reported by others. Recovery of virus plaque-forming units was highest from hydrophobic polytetrafluoro-ethylene membranes compared to hydrophobic polycarbonate screen filters or polyvinylidene difluoride depth filters, indicating that the method of virus recovery strongly affects the utility of a virus as an aerobiological marker. With this new method, surgical plume was indeed found in significant amounts when cutting tissue phantoms made with agar containing virus. The Electromagnetic Field Focusing System was used, which is a new thermal surgical device. The nominal power setting did not appear to be a factor in the amount of virus recovered. However, when pulse modulating the power by adjusting the crest factor from 1.4 to 4.3, a measure of the duty cycle for power delivery which adjusted the device from its cutting to haemostatic mode, a nearly five-fold increase in surgical plume, as evidence by the recovery of phi X-174 plaque forming units, was seen. The data indicate that bacteriophage phi X-174 can be used effectively as an aerobiological marker for aerosols generated during clinical procedures, and reinforce the need to use a safety vacuum during aerosol generating procedures. The availability of a safe and economical biological marker for aerosols from clinical procedures, which may lead to acquired infections in hospital personnel, makes evaluation of procedures and containment systems markedly easier. The data also indicates that surgical plume biohazard may be present in other techniques that employ pulse modulation including surgical lasers and electrocauteries.


Assuntos
Bacteriófago phi X 174/isolamento & purificação , Instrumentos Cirúrgicos , Aerossóis , Biomarcadores , Campos Eletromagnéticos , Replicação Viral
18.
Stereotact Funct Neurosurg ; 59(1-4): 128-34, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1295031

RESUMO

The intense heat produced at the tip of the electromagnetic field focusing (EFF) probe at its point of contact with tissue can cut and vaporize tissue and coagulate blood vessels. As the probe is shaped like a bayonet and has a diameter of 0.3 mm at its tip, it can be used on deep structures through narrow openings, making it ideal for stereotactic craniotomy. Thirteen stereotactic craniotomy procedures using the EFF system were performed. Locations of the lesions were deep in the cerebrum, cerebellum and in the lateral ventricle. The system proved efficient with reduced blood loss and unobstructed view of deep structures. No complications resulted from the use of the system.


Assuntos
Neoplasias Encefálicas/cirurgia , Campos Eletromagnéticos , Microcirurgia/instrumentação , Técnicas Estereotáxicas/instrumentação , Neoplasias Encefálicas/secundário , Craniotomia/instrumentação , Craniotomia/métodos , Glioma/cirurgia , Humanos , Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Microcirurgia/métodos , Neuroblastoma/cirurgia
19.
Angiology ; 42(7): 568-75, 1991 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-1863016

RESUMO

Nine canines were anesthetized with pentobarbital and studied by both selective and semiselective coronary artery angiography following intravenous bolus doses of 1,3,5,8, or 10 mg/kg of cocaine. Catheterization was accomplished with a 5 Fr catheter over a 0.035 inch guidewire under fluoroscopic control, and angiograms were obtained by injection of a diatrizoate solution. Digital subtraction angiography (DSA) was performed prior to cocaine administration and at minutes 0.5, 1, 1.5, 3, 5, and, in some cases, minutes 10 and 15 after cocaine administration. The 1 and 3 mg/kg doses of cocaine had no effect on the coronary arteries. The 5 mg/kg dose significantly dilated the coronary arteries. The 8 mg/kg dose produced significant dilation at 30 seconds after cocaine but nonsignificant dilation of the coronary arteries at all other times. The 10 mg/kg dose produced significant dilation at 30 seconds, nonsignificant dilation at 60 seconds followed by significant constriction at 90 seconds after cocaine, which led to immediate death in most animals. The coronary dilation and constriction produced by 10 mg/kg of cocaine could be prevented by either preadministration or postadministration of naloxone, but this did not prevent subsequent death.


Assuntos
Cocaína/farmacologia , Vasos Coronários/efeitos dos fármacos , Angiografia Digital , Animais , Angiografia Coronária , Cães , Relação Dose-Resposta a Droga , Feminino , Masculino , Sistema Vasomotor/efeitos dos fármacos
20.
Angiology ; 42(3): 195-201, 1991 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2018240

RESUMO

Electromagnetic field-focusing (EFF) probe is a precision surgical and interventional tool. Use of the device produces maximum temperature in excess of 1800 degrees C by convergence of radio-frequency (RF) induced eddy currents in biological tissues. Applications of the EFF probe in angioplasty, aneurysm thrombosis, and neurosurgery have been previously reported. In the present work, the EFF probe was guided under fluoroscopic control and used to occlude renal, splenic, and vertebral arteries in dogs. The occlusion was typically accomplished with about one minute of RF power application. Histology of the treated vessel three to six weeks posttreatment showed total occlusion consisting of intimal and subintimal changes and organized thrombus in the lumen. This suggests that the EFF probe in comparison with other procedures is an inexpensive, relatively safe precision interventional tool for performing an occlusion for experimental and therapeutic purposes.


Assuntos
Artérias/cirurgia , Campos Eletromagnéticos , Embolização Terapêutica/métodos , Animais , Artérias/patologia , Cães , Embolização Terapêutica/instrumentação , Fluoroscopia , Temperatura Alta , Artéria Renal/cirurgia , Artéria Esplênica/cirurgia , Artéria Vertebral/cirurgia