1.
Magn Reson Med Sci ; 22(4): 487-495, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36047248

RESUMO

PURPOSE: Amide proton transfer (APT) imaging may detect changes in tissues' pH based on the chemical exchange saturation transfer (CEST) phenomenon, and thus it may be useful for identifying the penumbra in ischemic stroke patients. We investigated the effect of saturation pulse duration and power on the APT effect in phantoms with different pH values. METHODS: Five samples were prepared from a 1:10 solution of egg-white albumin in phosphate-buffered saline at pH 6.53-7.65. The APT signal intensity (SI) was defined as asymmetry of the magnetization transfer ratio at 3.5 ppm. We measured the APT SIs in the egg-white albumin samples of different pH values with saturation pulse durations of 0.5, 1.0, 2.0, and 3.0 sec and saturation pulse powers of 0.5, 1.5, and 2.5 µT. The relative change in the APT SI in relation to the saturation duration and power at different pH values was defined as follows: (APT SI each saturation pulse - APT SI shortest or weakest pulse)/APT SIshortest or weakest pulse. The dependence of the APT SI on pH and the relative change in the APT SI were calculated as the slope of the linear regression. RESULTS: The lower the pH, the larger the relative change in the APT SI, due to the change in saturation pulse duration and power. The APT SI was highly correlated with the pH at all saturation pulse durations and powers. CONCLUSION: The influence of saturation duration and power on the APT effect was greater at lower pH than higher pH. The combination of saturation pulse ≥ 1.0 s and power ≥ 1.5 µT was useful for the sensitive detection of changes in APT effects in the egg-white albumin samples with different pH values.


Assuntos
Amidas , Prótons , Humanos , Imageamento por Ressonância Magnética/métodos , Albuminas , Concentração de Íons de Hidrogênio
2.
Neuroradiology ; 65(3): 529-538, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36434310

RESUMO

PURPOSE: Accurate assessment of cerebral perfusion in moyamoya disease is necessary to determine the indication for treatment. We aimed to investigate the usefulness of dynamic PCASL using a variable TR scheme with optimized background suppression in the evaluation of cerebral perfusion in moyamoya disease. METHODS: We retrospectively analyzed the images of 24 patients (6 men and 18 women, mean age 31.4 ± 18.2 years) with moyamoya disease; each of whom was imaged with both dynamic PCASL using the variable-TR scheme and 123IMP SPECT with acetazolamide challenge. ASL dynamic data at 10 phases are acquired by changing the LD and PLD. The background suppression timing was optimized for each phase. CBF and ATT were measured with ASL, and CBF and CVR to an acetazolamide challenge were measured with SPECT. RESULTS: A significant moderate correlation was found between the CBF measured by dynamic PCASL and that by SPECT (r = 0.53, P < 0.001). The CBF measured by dynamic PCASL (52.5 ± 13.3 ml/100 mg/min) was significantly higher than that measured by SPECT (43.0 ± 12.6 ml/100 mg/min, P < 0.001). The ATT measured by dynamic PCASL showed a significant correlation with the CVR measured by SPECT (r = 0.44, P < 0.001). ATT was significantly longer in areas where the CVR was impaired (CVR < 18.4%, ATT = 1812 ± 353 ms) than in areas where it was preserved (CVR > 18.4%, ATT = 1301 ± 437 ms, P < 0.001). The ROC analysis showed a moderate accuracy (AUC = 0.807, sensitivity = 87.7%, specificity = 70.4%) when the cutoff value of ATT was set at 1518 ms. CONCLUSION: Dynamic PCASL using this scheme was found to be useful for assessing cerebral perfusion in moyamoya disease.


Assuntos
Doença de Moyamoya , Masculino , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Acetazolamida , Marcadores de Spin , Estudos Retrospectivos , Circulação Cerebrovascular
3.
Br J Radiol ; 95(1135): 20211066, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35522787

RESUMO

OBJECTIVE: To develop and validate deep convolutional neural network (DCNN) models for the diagnosis of adrenal adenoma (AA) using CT. METHODS: This retrospective study enrolled 112 patients who underwent abdominal CT (non-contrast, early, and delayed phases) with 107 adrenal lesions (83 AAs and 24 non-AAs) confirmed pathologically and with 8 lesions confirmed by follow-up as metastatic carcinomas. Three patients had adrenal lesions on both sides. We constructed six DCNN models from six types of input images for comparison: non-contrast images only (Model A), delayed phase images only (Model B), three phasic images merged into a 3-channel (Model C), relative washout rate (RWR) image maps only (Model D), non-contrast and RWR maps merged into a 2-channel (Model E), and delayed phase and RWR maps merged into a 2-channel (Model F). These input images were prepared manually with cropping and registration of CT images. Each DCNN model with six convolutional layers was trained with data augmentation and hyperparameter tuning. The optimal threshold values for binary classification were determined from the receiver-operating characteristic curve analyses. We adopted the nested cross-validation method, in which the outer fivefold cross-validation was used to assess the diagnostic performance of the models and the inner fivefold cross-validation was used to tune hyperparameters of the models. RESULTS: The areas under the curve with 95% confidence intervals of Models A-F were 0.94 [0.90, 0.98], 0.80 [0.69, 0.89], 0.97 [0.94, 1.00], 0.92 [0.85, 0.97], 0.99 [0.97, 1.00] and 0.94 [0.86, 0.99], respectively. Model E showed high area under the curve greater than 0.95. CONCLUSION: DCNN models may be a useful tool for the diagnosis of AA using CT. ADVANCES IN KNOWLEDGE: The current study demonstrates a deep learning-based approach could differentiate adrenal adenoma from non-adenoma using multiphasic CT.


Assuntos
Adenoma , Aprendizado Profundo , Adenoma/diagnóstico por imagem , Adenoma/patologia , Humanos , Redes Neurais de Computação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
4.
J Nucl Med Technol ; 2022 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-35440474

RESUMO

This study investigated the spatial resolution and image quality of the continuous bed motion (CBM) method in a sensitive silicon photomultiplier (SiPM)-based positron emission tomography (PET)/computed tomography (CT) system compared with the traditional step-and-shoot (SS) method. Methods: Siemens Biograph Vision was used in this study. Data acquisition using the SS method was performed for 3 min per bed. In the CBM method, the bed speed ranged from 0.5 to 3.3 mm/s. The acquisition time equivalent to the SS method was 1.1 mm/s for 2-bed ranges and 0.8 mm/s for seven-bed ranges. The spatial resolution was investigated using 18F point sources and evaluated using the full width at half maximum. Image quality was investigated using a National Electrical Manufacturers Association International Electrotechnical Commission body phantom with six spheres 10-, 13-, 17-, 22-, 28-, and 37-mm inner diameters. The radioactivity concentration ratio of the 18F solution in all spheres and the background was approximately 4:1. The detectability of each sphere was visually evaluated on a five-step score. Image quality was physically evaluated using the noise equivalent count rate (NECphantom), contrast percentage of the 10-mm hot sphere (QH,10mm), background variability percentage (N10mm), and contrast-noise ratio (QH,10mm/N10mm). Results: The spatial resolution was not affected by the difference of acquisition methods and bed speeds. The detectability of the 10-mm sphere with a bed speed of 2.2 mm/s or faster was significantly inferior to that of the SS 2-bed method. In evaluating image quality, no significant difference in the contrast percentage was observed among the acquisition methods and speeds in the CBM method. However, the increasing bed speed in the CBM method increased the N10mm and decreased the NECphantom. When comparing the SS 2-bed method with the CBM method at 0.8 mm/s, no significant differences in all parameters were observed. Conclusion: In a SiPM-based PET/CT scanner, the CBM method provides equivalent spatial resolution and image quality in whole body PET images with same acquisition time using the SS method.

5.
Dentomaxillofac Radiol ; 51(1): 20200609, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34319774

RESUMO

OBJECTIVES: To compare the gamma distribution (GD), intravoxel incoherent motion (IVIM), and monoexponential (ME) models in terms of their goodness-of-fit, correlations among the parameters, and the effectiveness in the differential diagnosis of various orofacial lesions. METHODS: A total of 85 patients underwent turbo spin-echo diffusion-weighted imaging with six b-values. The goodness-of-fit of three models was assessed using Akaike Information Criterion. We analysed the correlations and compared the effectiveness in the differential diagnosis among the parameters of GD model (κ, shape parameter; θ, scale parameter; fractions of diffusion: ƒ1, cellular component; ƒ2, extracellular diffusion; ƒ3, perfusion component), IVIM model (D, true diffusion coefficient; D*, pseudodiffusion coefficient; f, perfusion fraction), and ME model (apparent diffusion coefficient, ADC). RESULTS: The GD and IVIM models showed a better goodness-of-fit than the ME model (p < 0.05). ƒ1 had strong negative correlations with D and ADC (ρ = -0.901 and -0.937, respectively), while ƒ3 had a moderate positive correlation with f (ρ = 0.661). Malignant entity presented significantly higher ƒ1 and lower D and ADC than benign entity (p < 0.0001). Malignant lymphoma had significantly higher ƒ1 in comparison to squamous cell carcinoma (p = 0.0007) and granulation (p = 0.0075). The trend in ƒ1 was opposite to the trend in D. Malignant lymphoma had significant lower ƒ3 than squamous cell carcinoma (p = 0.005) or granulation (p = 0.0075). CONCLUSIONS: The strong correlations were found between the GD- and IVIM-derived parameters. Furthermore, the GD model's parameters were useful for characterising the pathological structure in orofacial lesions.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Diagnóstico Diferencial , Humanos , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Magn Reson Imaging ; 85: 287-296, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34740801

RESUMO

PURPOSE: This study investigated the optimal labeling position and gradient moment for 4D-MR angiography based on superselective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) for vessel-selective flow visualization of the internal carotid artery (ICA) and vertebrobasilar artery (VBA) systems. METHODS: Seven healthy volunteers were scanned with a 3.0 T MR scanner. To visualize the ICA system, the labeling focus was placed in the right ICA at 55, 75 and 95 mm below the imaging slab. To visualize the VBA system, the labeling focus was placed in the basilar artery (BA), upper vertebral artery (VA upper), and lower vertebral artery (VA lower). Two sizes of labeling focus were created using gradient moments of 0.5 and 0.75 mT/m ms. The contrast-to-noise ratio (CNR) was measured in the middle cerebral artery (MCA) and posterior cerebral artery (PCA) branches. RESULTS: CNRs increased as the distance between the center of the imaging slab and the labeling position decreased in all MCA segments. CNRs obtained with VA lower tended to be higher than those obtained with BA and VA upper in all PCA segments. Selective vessel visualization was achieved with the gradient moment of 0.75 mT/m ms for the ICA and VBA system. CONCLUSION: The optimal 4D-S-PACK gradient moment was found to be 0.75 mT/m ms for the ICA and VBA systems. When visualizing the ICA system, the labeling position should be placed as close as possible to the imaging slab. When visualizing the VBA system, the labeling position should be placed at VA lower .


Assuntos
Artéria Carótida Interna , Angiografia por Ressonância Magnética , Angiografia Digital/métodos , Artéria Carótida Interna/diagnóstico por imagem , Humanos , Angiografia por Ressonância Magnética/métodos , Artéria Cerebral Média , Marcadores de Spin
7.
PLoS One ; 16(9): e0256471, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34492075

RESUMO

PURPOSE: Most small renal cell carcinomas (small RCCs) will remain indolent after detection, but some stage I RCCs still metastasize. There are no risk-stratification imaging factors that could be used to identify poor-prognosis patients based on genomic profiling. Here, we evaluated the relationships between imaging parameters and RNA expressions in small RCC and attempted to identify imaging factors that could be used as effective biomarkers. METHODS: We acquired biopsy specimens of 18 clear cell carcinomas that had undergone perfusion CT (pCT) and MRI between April 2018 and March 2019. We performed RNA sequencing, assessed RNA expressions, and calculated each tumor's cell-cycle progression (CCP) score, which has prognostic value in predicting metastatic progression. We classified the tumors into two groups: clear cell type A (ccA) and type B (ccB). CcA has better survival compared to ccB. We evaluated the following characteristics of each tumor: tumor size, presence of pseudocapsule, and fat. We used the pCT and MRI to measure each tumor's volume transfer constant (Ktrans), rate constant (Kep), extracellular extravascular volume fraction (VE), fractional plasma volume (VP), and apparent diffusion coefficient (ADC). The correlations between these small RCC imaging parameters and the tumor size and RNA expressions were determined. RESULTS: The tumor size was significantly correlated with Kep and inversely correlated with VE, VP, ADC, and hallmark angiogenesis. The CCP score was significantly inversely correlated with Ktrans and Kep. The ccA tumors tended to show a pseudocapsule on MRI. CONCLUSION: Tumor size was correlated with low perfusion, but not with prognostic factors based on genomic profiling. Imaging parameters (e.g., Ktrans and Kep) and tumor characteristics (e.g., pseudocapsule) may enable gene-based risk stratification in small RCC.


Assuntos
Carcinoma de Células Renais/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Neovascularização Patológica/diagnóstico , Prognóstico , Idoso , Idoso de 80 Anos ou mais , Biópsia , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Meios de Contraste/administração & dosagem , Feminino , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/patologia , Medição de Risco
8.
Magn Reson Imaging ; 76: 87-95, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33232768

RESUMO

PURPOSE: Multi-spin echo acquisition cine imaging (MUSACI) is a method used for cerebrospinal fluid (CSF) dynamics imaging based on the proton phase dispersion and flow void using 3D multi-spin echo imaging. In a previous study, the refocusing flip angle of MUSACI was set at a constant 80°. We conducted the present study to investigate the preservation the CSF signal intensity even in a long echo train and improve the ability to visualize CSF movement by modifying the refocusing flip angle in MUSACI. METHODS: The MUSACI images were acquired in 10 healthy volunteers (7 men and 3 women; age range 24-44 years; mean age 29.4 ±â€¯6.2 years) with a 3.0 Tesla MR scanner. Five refocusing flip angle sets were applied: constant 30°, constant 50°, constant 80°, pseudo-steady state (PSS) 50°-70°-100° (PSS50°), and PSS80°-100°-130° (PSS80°). In all sequences, the in-plane spatial resolution was 0.58 × 0.58 mm2, and the CSF movement for one heartbeat was drawn at 80-msec intervals. The signal intensity (SI) of CSF in the lateral ventricle, the foramen of Monro, the third ventricle, the fourth ventricle, and the pons was measured on MUSACI. Pearson's correlation coefficient was calculated between the CSF SI and effective echo time (TE; TEeff) in the lateral ventricle. RESULTS: Both antegrade and retrograde CSF movements on the midsagittal MUSACI images and the retrograde CSF movement in the foramen of Monro was observed in all sequences with the constant flip angles. A strong reverse correlation between the CSF SI in the lateral ventricle and TEeff values was observed with constant 30° (r = -0.96, p < 0.01), constant 50° (r = -0.97, p < 0.01) and constant 80° (r = -0.88, p < 0.01). A weak positive correlation was observed with PSS50° (r = 0.28, p = 0.43), and a moderate reverse correlation was observed at PSS80° (r = -0.60, p = 0.07). The SI values of the foramen of Monro, the third ventricle, and the fourth ventricle were significantly lower than that of the lateral ventricle, and those values were higher than that of the pons in both the constant 80° sequence and the PSS 50° sequence. CONCLUSION: PSS50° could be the optimal flip angle scheme for MUSACI, because the SI changes due to CSF movement and the SI preservation due to a long echo train were large due to the use of the refocusing flip angle method.


Assuntos
Líquido Cefalorraquidiano/diagnóstico por imagem , Líquido Cefalorraquidiano/fisiologia , Hidrodinâmica , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Adulto Jovem
9.
Dentomaxillofac Radiol ; 50(2): 20200252, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32706975

RESUMO

OBJECTIVES: This study evaluated the correlation among the diffusion-derived parameters obtained by monoexponential (ME), intravoxel incoherent motion (IVIM) and γ distribution (GD) models and compared these parameters among representative orofacial tumours. METHODS: Ninety-two patients who underwent 1.5 T MRI including diffusion-weighted imaging were included. The shape parameter (κ), scale parameter (θ), ratio of the intracellular diffusion (ƒ1), extracellular diffusion (ƒ2) and perfusion (ƒ3) were obtained by the GD model; the true diffusion coefficient (D) and perfusion fraction (f) were obtained by the IVIM model; and the apparent diffusion coefficient (ADC) was obtained by the ME model. RESULTS: ƒ1 had a strongly negative correlation with the ADC (ρ = -0.993) and D (ρ = -0.926). A strong positive correlation between f and ƒ3 (ρ = 0.709) was found. Malignant lymphoma (ML) had the highest ƒ1, followed by squamous cell carcinoma (SCC), malignant salivary gland tumours, pleomorphic adenoma (Pleo) and angioma. Both the IVIM and GD models suggested the highest perfusion in angioma and the lowest perfusion in ML. The GD model demonstrated a high extracellular component in Pleo and revealed that the T4a+T4b SCC group had a lower ƒ2 than the T2+T3 SCC group, and poor to moderately differentiated SCC had a higher ƒ1 than highly differentiated SCC. CONCLUSIONS: Given the correlation among the diffusion-derived parameters, the GD model might be a good alternative to the IVIM model. Furthermore, the GD model's parameters were useful for characterizing the pathological structure.


Assuntos
Carcinoma de Células Escamosas , Imagem de Difusão por Ressonância Magnética , Carcinoma de Células Escamosas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Perfusão
10.
MAGMA ; 33(4): 515-516, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32060671

RESUMO

The original version of this article unfortunately contained a mistake. Second column of "Cell edema" should read as.

11.
MAGMA ; 33(4): 507-513, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31897902

RESUMO

OBJECTIVE: A phantom for diffusion-weighted imaging is required to standardize quantitative evaluation. The objectives were to develop a phantom simulating various cell densities and to evaluate repeatability. MATERIALS AND METHODS: The acrylic fine particles with three different diameters were used to simulate human cells. Four-degree cell density components were developed by adjusting the volume of 10-µm particles (5, 20, 35, and 50% volume, respectively). Two-degree components to simulate cell edema were also developed by adjusting the diameter without changing number (17% and 40% volume, respectively). Spearman's rank correlation coefficient was used to find a significant correlation between apparent diffusion coefficient (ADC) and particle density. Coefficient of variation (CV) for ADC was calculated for each component for 6 months. A p value < 0.05 represented a statistically significance. RESULTS: Each component (particle ratio of 5, 17, 20, 35, 40, and 50% volume, respectively) presented ADC values of 1.42, 1.30, 1.30, 1.12, 1.09, and 0.89 (× 10-3 mm2/s), respectively. A negative correlation (r = - 0.986, p < 0.05) was observed between ADC values and particle ratio. CV for ADC was less than 5%. DISCUSSION: A phantom simulating the diffusion restriction correlating with cell density and size could be developed.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/métodos , Edema/diagnóstico por imagem , Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Resinas Sintéticas/química , Detergentes , Difusão , Edema/fisiopatologia , Humanos , Modelos Lineares , Teste de Materiais , Neoplasias/fisiopatologia , Tamanho da Partícula , Água/química
12.
MAGMA ; 33(2): 293-298, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31552552

RESUMO

OBJECTIVES: It is necessary to standardize the examination procedure and diagnostic criteria of diffusion tensor imaging (DTI). Thus, the purpose of this study was to examine the reproducibility of measurements using a standardization phantom composed of different fibre materials with different fibre densities (FDs) for the evaluation of fractional anisotropy (FA) derived from DTI. MATERIALS AND METHODS: Two types of fibre materials wrapped in heat-shrinkable tubes were used as fibre phantoms. We designed fibre phantoms with three different FDs of each fibre material. The standardization phantom was examined using DTI protocol six times a day, and each examination session was repeated once a month for 7 consecutive months. Fibre tracking was performed by setting regions of interest in the FA map, and FA was measured in each fibre phantom. Coefficients of variation (CVs) were used to evaluate the inter-examination reproducibility of FA values. Furthermore, Bland-Altman plots were used to evaluate the intra-operator reproducibility of FA measurements. RESULTS: All CVs for each fibre phantom were within 2% throughout the 7-month study of repeated DTI sessions. The high intra-operator reproducibility of the FA measurement was confirmed. DISCUSSION: High reproducibility of measurements using a standardization phantom for the evaluation of FA was achieved.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Imagens de Fantasmas , Anisotropia , Humanos , Imageamento por Ressonância Magnética , Padrões de Referência , Reprodutibilidade dos Testes
13.
Magn Reson Med ; 81(1): 331-341, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30194785

RESUMO

PURPOSE: To evaluate the visualization of CSF dynamics using the novel method multi-spin echo acquisition cine imaging (MUSACI). METHODS: MUSACI is based on multi-echo volume isotropic turbo spin-echo acquisition (VISTA) with pulse gating. MUSACI images were acquired in 11 healthy volunteers (7 men, 4 women; age range, 24-46 y, mean age, 31.9 ± 5.51 y). We compared the CSF signal intensities (SIs) at multiple values of the effective echo time (TEeff ) at the lateral ventricle, the foramen of Monro, the third ventricle, and the fourth ventricle. We compared the CSF SI changes in MUSACI at multiple TEeff and the mean velocities in phase contrast (PC) at each trigger delay at the foramen of Monro, the third ventricle, and the fourth ventricle. RESULTS: The anterograde CSF motion from the aqueduct to the fourth ventricle, the retrograde motion from the aqueduct to the third ventricle, and the retrograde motion from the foramen of Monro to the lateral ventricle were observed with MUSACI. The CSF SIs at each TEeff in the foramen of Monro, the third ventricle, and the fourth ventricle were significantly lower than that at each TEeff in the lateral ventricle (P < 0.05). The CSF SI in MUSACI changed with the TEeff , and the CSF movements were observed at each trigger delay in PC. CONCLUSION: MUSACI can provide both high-resolution anatomical detail of the CSF passageways and physiologic information regarding CSF dynamics in a single scan.


Assuntos
Ventrículos Cerebrais/diagnóstico por imagem , Líquido Cefalorraquidiano/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Adulto , Líquido Cefalorraquidiano/fisiologia , Feminino , Voluntários Saudáveis , Humanos , Hidrocefalia/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Imagens de Fantasmas
14.
Acad Radiol ; 26(10): e305-e316, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30528753

RESUMO

RATIONALE AND OBJECTIVES: We aimed to compare the distortion ratio (DR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the orofacial region and prove the usefulness of TSE-DWI for the differential diagnosis of orofacial lesions. MATERIALS AND METHODS: The DR, SNR, and CNR of both sequences were compared in 42 cases. Then, the apparent diffusion coefficient (ADC) of various orofacial lesions obtained by TSE-DWI was investigated in 143 lesions. RESULTS: In the first study, 38 of 42 cases were analyzed. TSE-DWI showed a significantly lower DR (p < 0.05) and higher SNR and CNR than EPI-DWI (p < 0.05), indicating the superiority of TSE-DWI. In the second study, 114 cases (79.3%) were successfully analyzed. When lesions were divided into cysts, benign tumors, squamous cell carcinoma, malignant lymphoma, and other malignant tumors (OT), significant differences were observed in all pairs of lesions (p < 0.05) except squamous cell carcinoma and OT (p = 0.877). The area under the curve for distinguishing benign from malignant tumors was 0.80 with a cutoff ADC of 1.29 × 10-3 mm²/s. CONCLUSION: TSE-DWI produced better quality images than EPI-DWI. TSE-DWI yields the high possibility of obtaining ADC in the orofacial region, and this value was considered useful for the differential diagnosis of orofacial lesions.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Razão Sinal-Ruído
15.
Br J Radiol ; 91(1085): 20170671, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29376736

RESUMO

OBJECTIVE: Our first objective was to prove the validity of the six-point Dixon method for estimating the proton density fat fraction (PDFF) of the salivary gland. The second objective was to estimate the salivary gland PDFF using Dixon method to evaluate the pathological conditions. METHODS: At first, 12 volunteers underwent two types of sequences: single-voxel magnetic resonance spectroscopy and the Dixon method and the PDFFs obtained by the two methods were compared. Next, a total of 67 individuals [normal, n = 46; Sjögren's syndrome (SS), n = 11; and IgG4-related dacryoadenitis and sialadenitis (IgG4-DS), n = 4, parotitis, n = 6] were enrolled to estimate the parotid gland (PG) and submandibular gland (SMG) PDFF using the Dixon method. RESULTS: This volunteer study demonstrated excellent correlation between two methods (R2 = 0.964, slope = 1.05). In the normal group, the PG-PDFF was correlated with the weight and body mass index (BMI) (ρ = 0.38, p = 0.0085; and ρ = 0.63, p < 0.0001). The SMG-PDFF was also correlated with the weight, BMI, and serum triglyceride (ρ = 0.37, p = 0.0067; ρ = 0.42, p = 0.0022; and ρ = 0.35, p = 0.024). The PG-PDFF of the SS group (48.2 ± 15.1%) was higher than that of any other groups; however, no significant difference was found due to the wide overlap. The SS group (39.0 ± 26.14%) also had significantly higher SMG-PDFF than the normal group (8.9 ± 5.4%), p < 0.0001) and IgG4-DS group (3.8 ± 2.3%), p = 0.020). CONCLUSION: The Dixon method is a feasible method for estimating the PDFF and demonstrates fat accumulation in SMG in the SS group. Advances in knowledge: The PDFF obtained by the Dixon method is helpful for understanding the salivary gland pathological condition.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Espectroscopia de Ressonância Magnética/métodos , Glândulas Salivares/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prótons , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
Asia Ocean J Nucl Med Biol ; 6(1): 24-31, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29333464

RESUMO

OBJECTIVES: Yttrium-90 (90Y) is a beta particle nuclide used in targeted radionuclide therapy which is available to both single-photon emission computed tomography (SPECT) and time-of-flight (TOF) positron emission tomography (PET) imaging. The purpose of this study was to assess the image quality of PET and Bremsstrahlung SPECT by simulating PET and SPECT images of 90Y using Monte Carlo simulation codes under the same conditions and to compare them. METHODS: In-house Monte Carlo codes, MCEP-PET and MCEP-SPECT, were employed to simulate images. The phantom was a torso-shaped phantom containing six hot spheres of various sizes. The background concentrations of 90Y were set to 50, 100, 150, and 200 kBq/mL, and the concentrations of the hot spheres were 10, 20, and 40 times of those of the background concentrations. The acquisition time was set to 30 min, and the simulated sinogram data were reconstructed using the ordered subset expectation maximization method. The contrast recovery coefficient (CRC) and contrast-to-noise ratio (CNR) were employed to evaluate the image qualities. RESULTS: The CRC values of SPECT images were less than 40%, while those of PET images were more than 40% when the hot sphere was larger than 20 mm in diameter. The CNR values of PET images of hot spheres of diameter smaller than 20 mm were larger than those of SPECT images. The CNR values mostly exceeded 4, which is a criterion to evaluate the discernibility of hot areas. In the case of SPECT, hot spheres of diameter smaller than 20 mm were not discernable. On the contrary, the CNR values of PET images decreased to the level of SPECT, in the case of low concentration. CONCLUSION: In almost all the cases examined in this investigation, the quantitative indexes of TOF-PET 90Y images were better than those of Bremsstrahlung SPECT images. However, the superiority of PET image became critical in the case of low activity concentrations.

17.
Br J Radiol ; 90(1077): 20160704, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28707990

RESUMO

OBJECTIVE: To estimate the fat fraction (FF) in the salivary glands (SGs) by the mDIXON method and the 1H-MR spectroscopy (MRS) method, and to compare the results. METHODS: 16 healthy volunteers were enrolled. mDIXON Quant and MRS (point-resolved spectroscopy: PRESS) with a single TE were employed to measure the FF in the parotid gland (PG) and submandibular gland (SMG). Multiple TEs were applied in 10 volunteers to correct for T2 decay. In addition, we assumed that the 1.3 ppm peak accounted for 60% of the total fat peak and estimated the FF (MRS all) as a gold standard. On mDIXON Quant images, volumes of interest were set on the bilateral SGs and we obtained the FF (mDIXON) of each volume of interest. RESULTS: There was a strong correlation between the results of the mDIXON Quant method and the MRS (single TE) method (R2 = 0.960, slope = 0.900). Using PRESS with multiple TEs, there was also a strong correlation between FF (mDIXON) and FF (MRS all) (R2 = 0.963, slope = 1.18). FF (MRS all) was 24.9±12.7% in the PG and 4.5±3.0% in the SMG, while FF (mDIXON) was 29.4±16.2% in the PG and 6.4±4.7% in the SMG. There were no significant differences between the two methods, but the Bland-Altman plot showed that FF (mDIXON) was slightly larger than FF (MRS all) for small FF areas. CONCLUSION: The mDIXON Quant method could be clinically useful for evaluating the FF of SGs, but the absolute values need careful interpretation. Advance in knowledge: This study suggested the potential clinical usefulness of the mDIXON Quant method for the SGs.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Glândulas Salivares/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
18.
J Magn Reson Imaging ; 45(3): 863-871, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27439061

RESUMO

PURPOSE: To evaluate the dependence of saturation pulse power and duration on glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging and assess the degeneration of human lumbar intervertebral discs (IVDs) using this method. MATERIALS AND METHODS: All images were acquired on a 3T magnetic resonance imaging (MRI) scanner. The CEST effects were measured in the glycosaminoglycan (GAG) phantoms with different concentrations. In the human study, CEST effects were measured in the nucleus pulposus of IVD. We compared the CEST effects among the different saturation pulse powers (0.4, 0.8, and 1.6 µT) or durations (0.5, 1.0, and 2.0 sec) at each Pfirrmann grade (I-V). The relationship between the CEST effects and low back pain was also evaluated. RESULTS: The phantom study showed high correlations between the CEST effects and GAG concentration (R2 = 0.863, P < 0.0001, linear regression). In the human study, the CEST effect obtained with the 0.8 µT power was significantly greater than those obtained with 0.4 (P < 0.01) and 1.6 µT power (P < 0.05) at Pfirrmann grade I. The CEST effect obtained with a 1.0-sec duration was significantly greater than those derived with 0.5 and 2.0 sec (P < 0.01) durations at Pfirrmann grades I and II. The CEST effects in the group with moderate low back pain were significantly lower than those in the groups without pain (P < 0.001) and with mild pain (P = 0.0216). CONCLUSION: The contrast of gagCEST imaging in the lumbar IVDs varied with saturation pulse power and duration. GagCEST imaging may serve as a tool for evaluating IVD degeneration in the lumbar spine. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:863-871.


Assuntos
Glicosaminoglicanos/metabolismo , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/metabolismo , Dor Lombar/diagnóstico por imagem , Dor Lombar/metabolismo , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adulto , Biomarcadores/metabolismo , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Degeneração do Disco Intervertebral/complicações , Dor Lombar/etiologia , Masculino , Imagem Molecular/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Ann Nucl Med ; 30(10): 675-681, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27510893

RESUMO

OBJECTIVE: 90Y-ibritumomab tiuxetan (Zevalin) which is used for the treatment of malignant lymphomas can be used for SPECT imaging based on bremsstrahlung from 90Y beta particles. However, gamma rays emitted by 111In, which is administered to evaluate the indication for the treatment, contaminate the 90Y bremsstrahlung images. Our objective is to investigate the influence of 111In on the 90Y SPECT images using Monte Carlo simulation. METHODS: We used an in-house developed simulation code for the Monte Carlo simulation of electrons and photons (MCEP). Two hot spheres with diameters of 40 mm were put in an elliptical phantom. Both spheres ("sphere 1" and "sphere 2") were filled with 90Y and 111In mixed solutions. The activities of 90Y in sphere 1 and sphere 2 were 241 and 394 kBq/mL, respectively, and the ones of 111In were 8.14 and 13.3 kBq/mL, respectively. The background activity of 90Y was 38.6 kBq/mL, whereas that of 111In was 1.30 kBq/mL; moreover, the acquisition time was 30 min. Two energy windows were used: one is 90-190 keV included the 111In photopeak; the other is 90-160 keV. To evaluate the quality of the SPECT images, the contrast recovery coefficient (CRC) and the constant noise ratio (CNR) of the SPECT images were derived. RESULTS: For the energy window between 90 and 160 keV, the 111In count was 74 % of the total. In that case, the CRC values were 30.1 and 30.7 % for "sphere 1" and "sphere 2", respectively, whereas the CNR values were 6.8 and 12.1, respectively. For the energy window between 90 and 190 keV, the 111In count reached 85 % of the total count. The CRC and CNR values were 38.6 and 40.0 % and 10.6 and 19.4, respectively. CONCLUSIONS: Our simulation study revealed that the cross talk between 111In and 90Y in SPECT imaging is rather serious. Even for the energy window excluding the 111In photopeak, the count ratio of 90Y was less than 30 % of the total. However, the influence of 111In on 90Y-SPECT imaging cannot be ignored, and the count ratio because of 111In is important to estimate the density of 90Y.


Assuntos
Radioisótopos de Índio , Método de Monte Carlo , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio , Imagens de Fantasmas
20.
Asia Ocean J Nucl Med Biol ; 4(2): 72-80, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27408895

RESUMO

OBJECTIVES: The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods. METHODS: An anthropomorphic striatal phantom was filled with (123)I solutions at different striatum-to-background radioactivity ratios. Data were acquired using two SPECT/CT devices, equipped with a low-to-medium-energy general-purpose collimator (cameras A-1 and B-1) and a low-energy high-resolution (LEHR) collimator (cameras A-2 and B-2). The SPECT images were once reconstructed by FBP using Chang's AC and once by ordered subset expectation maximization (OSEM) using both CTAC and Chang's AC; moreover, scatter correction was performed. OSEM on cameras A-1 and A-2 included resolution recovery (RR). The images were analyzed, using the specific binding ratio (SBR). Regions of interest for the background were placed on both frontal and occipital regions. RESULTS: The optimal number of iterations and subsets was 10i10s on camera A-1, 10i5s on camera A-2, and 7i6s on cameras B-1 and B-2. The optimal full width at half maximum of the Gaussian filter was 2.5 times the pixel size. In the comparison between FBP and OSEM, the quality was superior on OSEM-reconstructed images, although edge artifacts were observed in cameras A-1 and A-2. The SBR recovery of OSEM was higher than that of FBP on cameras A-1 and A-2, while no significant difference was detected on cameras B-1 and B-2. Good linearity of SBR was observed in all cameras. In the comparison between Chang's AC and CTAC, a significant correlation was observed on all cameras. The difference in the background region influenced SBR differently in Chang's AC and CTAC on cameras A-1 and B-1. CONCLUSION: Iterative reconstruction improved image quality on all cameras, although edge artifacts were observed in images captured by cameras with RR. The SBR of OSEM with RR was higher than that of FBP, while the SBR of OSEM without RR was equal to that of FBP. Also, the SBR of Chang's AC varied with different background regions in cameras A-1 and B-1.