1.
J Appl Clin Med Phys ; 25(7): e14325, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38467039

RESUMO

PURPOSE: The picket fence (PF) test is highly recommended for multi-leaf collimator (MLC) quality assurance. However, since the electronic portal imaging device (EPID) on the Elekta Unity only covers a small area, it is not feasible to perform the PF test for the entire MLC. Here, we propose a technique for the PF test by stitching two double-exposed films. METHODS: Two EBT3 films were used to encompass the entire MLC, with each one covering one half of the area. Two fields were employed to apply double exposure: a PF pattern consisting of 11 2 mm wide pickets and a 2.84 cm x 22 cm open field. The edges of the open field defined by the diaphragms were used to correct film rotation as well as align them horizontally. The PF pattern was also measured with the EPID where the pickets were used to align the films vertically. Individual leaf positions were detected on the merged film for quantitative analysis. Various MLC positioning errors were introduced to evaluate the technique's sensitivity. RESULTS: The merged films covered 72 leaf pairs properly (four leaf pairs on both sides were outside the treatment couch). With the EPID, the leaf positioning accuracy was -0.02 ± 0.07 mm (maximum: 0.29 mm) and the picket width variation was 0.00 ± 0.03 mm (maximum: 0.11 mm); with the films, the position accuracy and width variation were -0.03 ± 0.13 mm (maximum: 0.80 mm) and 0.00 ± 0.13 mm (maximum: 0.74 mm), respectively. The EPID was able to detect errors of 0.5 mm or above with submillimeter accuracy; the films were only able to detect errors > 1.0 mm. CONCLUSION: We developed a quantitative technique for the PF test on the Elekta Unity. The merged films covered nearly the entire MLC leaf banks. The technique exhibited clinically acceptable accuracy and sensitivity to MLC positioning errors.


Assuntos
Aceleradores de Partículas , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia de Intensidade Modulada/métodos , Aceleradores de Partículas/instrumentação , Imageamento por Ressonância Magnética/métodos , Dosimetria Fotográfica/métodos , Dosimetria Fotográfica/instrumentação , Imagens de Fantasmas , Neoplasias/radioterapia
2.
Med Phys ; 49(6): 4026-4042, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35355285

RESUMO

PURPOSE: Most commercially available treatment planning systems (TPSs) approximate the continuous delivery of volumetric modulated arc therapy (VMAT) plans with a series of discretized static beams for treatment planning, which can make VMAT dose computation extremely inefficient. In this study, we developed a polar-coordinate-based pencil beam (PB) algorithm for efficient VMAT dose computation with high-resolution gantry angle sampling that can improve the computational efficiency and reduce the dose discrepancy due to the angular under-sampling effect. METHODS AND MATERIALS: 6 MV 1 × 1 m m 2 $1 \times 1{\rm{\;m}}{{\rm{m}}^2}$ pencil beams were simulated on a uniform cylindrical phantom under an EGSnrc Monte Carlo (MC) environment. The MC-generated PB kernels were collected in the polar coordinate system for each bixel on a 40 × 40 c m 2 $40 \times 40{\rm{\;c}}{{\rm{m}}^2}$ fluence map and subsequently fitted via a series of Gaussians. The fluence was calculated using a detectors' eye view with off-axis and MLC transmission factors corrected. Doses of VMAT arc on the phantom were computed by summing the convolution results between the corresponding PB kernels and fluence for each bixel in the polar coordinate system. The convolution was performed using fast Fourier transform to expedite the computing speed. The calculated doses were converted to the Cartesian coordinate system and compared with the reference dose computed by a collapsed cone convolution (CCC) algorithm of the TPS. A heterogeneous phantom was created to study the heterogeneity corrections using the proposed algorithm. Ten VMAT arcs were included to evaluate the algorithm performance. Gamma analysis and computation complexity theory were used to measure the dosimetric accuracy and computational efficiency, respectively. RESULTS: The dosimetric comparisons on the homogeneous phantom between the proposed PB algorithm and the CCC algorithm for 10 VMAT arcs demonstrate that the proposed algorithm can achieve a dosimetric accuracy comparable to that of the CCC algorithm with average gamma passing rates of 96% (2%/2mm) and 98% (3%/3mm). In addition, the proposed algorithm can provide better computational efficiency for VMAT dose computation using a PC equipped with a 4-core processor, compared to the CCC algorithm utilizing a dual 10-core server. Moreover, the computation complexity theory reveals that the proposed algorithm has a great advantage with regard to computational efficiency for VMAT dose computation on homogeneous medium, especially when a fine angular sampling rate is applied. This can support a reduction in dose errors from the angular under-sampling effect by using a finer angular sampling rate, while still preserving a practical computing speed. For dose calculation on the heterogeneous phantom, the proposed algorithm with heterogeneity corrections can still offer a reasonable dosimetric accuracy with comparable computational efficiency to that of the CCC algorithm. CONCLUSIONS: We proposed a novel polar-coordinate-based pencil beam algorithm for VMAT dose computation that enables a better computational efficiency while maintaining clinically acceptable dosimetric accuracy and reducing dose error caused by the angular under-sampling effect. It also provides a flexible VMAT dose computation structure that allows adjustable sampling rates and direct dose computation in regions of interest, which makes the algorithm potentially useful for clinical applications such as independent dose verification for VMAT patient-specific QA.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Algoritmos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
3.
J Appl Clin Med Phys ; 22(12): 64-71, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34633745

RESUMO

The purpose of this work is to study the feasibility of photon beam profile deconvolution using a feedforward neural network (NN) in very small fields (down to 0.56 × 0.56 cm2 ). The method's independence of the delivery and scanning system is also investigated. Lateral beam profiles of photon fields between 0.56 × 0.56 cm2 and 4.03 × 4.03 cm2 were collected on a Siemens Artiste linear accelerator. Three scanning ionization chambers (SNC 125c, PTW 31021, and PTW 31022) of sensitive volumes ranging from 0.016 cm3 to 0.108 cm3 were used with a PTW MP3 water phantom. A reference dataset was also collected with a PTW 60019 microDiamond detector to train and test individual NNs for each ionization chamber. Further testing of the trained NNs was performed with additional test data collected on an Elekta Synergy linear accelerator using a Sun Nuclear 3D Scanner. The results were evaluated with a 1D gamma analysis (0.5 mm/0.5%). After the deconvolution, the gamma passing rates increased from 54.79% to 99.58% for the SNC 125c, from 57.09% to 99.83% for the PTW 31021, and from 91.03% to 96.36% for the PTW 31022. The delivery system, the scanning system, the scanning mode (continuous vs. step-by-step), and the electrometer had no significant influence on the results. This study successfully demonstrated the feasibility of using NN to correct the beam profiles of very small photon fields collected with ionization chambers of various sizes. Its independence of the delivery and scanning system was also shown.


Assuntos
Aceleradores de Partículas , Radiometria , Humanos , Redes Neurais de Computação , Imagens de Fantasmas , Fótons
4.
J Appl Clin Med Phys ; 22(10): 161-168, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34486800

RESUMO

PURPOSE: The use of the ionization chamber array ICProfiler (ICP) is limited by its relatively poor detector spatial resolution and the inherent volume averaging effect (VAE). The purpose of this work is to study the feasibility of reconstructing VAE-free continuous photon beam profiles from ICP measurements with a machine learning technique. METHODS: In- and cross-plane photon beam profiles of a 6 MV beam from an Elekta linear accelerator, ranging from 2 × 2 to 10 × 10 cm2 at 1.5 cm, 5 cm, and 10 cm depth, were measured with an ICP. The discrete measurements were interpolated with a Makima method to obtain continuous beam profiles. Artificial neural networks (ANNs) were trained to restore the penumbra of the beam profiles. Plane-specific (in- and cr-plane) ANNs and a combined ANN were separately trained. The performance of the ANNs was evaluated using the penumbra width difference (PWD, the difference between the penumbra widths of the reconstructed and the reference profile). The plane-specific and the combined ANNs were compared to study the feasibility of using a single ANN for both in- and cross-plane. RESULTS: The profiles reconstructed with all the ANNs had excellent agreement with the reference. For in-plane, the ANNs reduced the PWD from 1.6 ± 0.7 mm at 1.5 cm depth to 0.1 ± 0.1 mm, from 1.8 ± 0.6 mm at 5.0 cm depth to 0.1 ± 0.1 mm, and from 2.4 ± 0.1 mm at 10.0 cm depth to 0.0 ± 0.0 mm; for cross-plane, the ANNs reduced the PWD from 1.2 ± 0.4 mm at 1.5 cm depth, 1.2 ± 0.3 mm at 5.0 cm depth, and 1.6 ± 0.1 mm at 10.0 cm depth, to 0.1 ± 0.1 mm. CONCLUSIONS: This study demonstrated the feasibility of using simple ANNs to reconstruct VAE-free continuous photon beam profiles from discrete ICP measurements. A combined ANN can restore the penumbra of in- and cross-plane beam profiles of various fields at different depths.


Assuntos
Fótons , Radiometria , Humanos , Aprendizado de Máquina , Redes Neurais de Computação , Aceleradores de Partículas
5.
Med Phys ; 47(10): 5077-5089, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32463944

RESUMO

PURPOSE: Directly extracting the respiratory phase pattern of the tumor using cone-beam computed tomography (CBCT) projections is challenging due to the poor tumor visibility caused by the obstruction of multiple anatomic structures on the beam's eye view. Predicting tumor phase information using external surrogate also has intrinsic difficulties as the phase patterns between surrogates and tumors are not necessary to be congruent. In this work, we developed an algorithm to accurately recover the primary oscillation components of tumor motion using the combined information from both CBCT projections and external surrogates. METHODS: The algorithm involved two steps. First, a preliminary tumor phase pattern was acquired by applying local principal component analysis (LPCA) on the cropped Amsterdam Shroud (AS) images. In this step, only the cropped image of the tumor region was used to extract the tumor phase pattern in order to minimize the impact of pattern recognition from other anatomic structures. Second, by performing multivariate singular spectrum analysis (MSSA) on the combined information containing both external surrogate signal and the original waveform acquired in the first step, the primary component of the tumor phase oscillation was recovered. For the phantom study, a QUASAR respiratory motion phantom with a removable tumor-simulator insert was employed to acquire CBCT projection images. A comparison between LPCA only and our method was assessed by power spectrum analysis. Also, the motion pattern was simulated under the phase shift or various amplitude conditions to examine the robustness of our method. Finally, anatomic obstruction scenarios were simulated by attaching a heart model, PVC tubes, and RANDO® phantom slabs to the phantom, respectively. Each scenario was tested with five real-patient breathing patterns to mimic real clinical situations. For the patient study, eight patients with various tumor locations were selected. The performance of our method was then evaluated by comparing the reference waveform with the extracted signal for overall phase discrepancy, expiration phase discrepancy, peak, and valley accuracy. RESULTS: In tests of phase shifts and amplitude variations, the overall peak and valley accuracy was -0.009 ± 0.18 sec, and no time delay was found compared to the reference. In anatomical obstruction tests, the extracted signal had 1.6 ± 1.2 % expiration phase discrepancy, -0.12 ± 0.28 sec peak accuracy, and 0.01 ± 0.15 sec valley accuracy. For patient studies, the extracted signal using our method had -1.05 ± 3.0 % overall phase discrepancy, -1.55 ± 1.45% expiration phase discrepancy, 0.04 ± 0.13 sec peak accuracy, and -0.01 ± 0.15 sec valley accuracy, compared to the reference waveforms. CONCLUSIONS: An innovative method capable of accurately recognizing tumor phase information was developed. With the aid of extra information from the external surrogate, an improvement in prediction accuracy, as compared with traditional statistical methods, was obtained. It enables us to employ it as the ground truth for 4D-CBCT reconstruction, gating treatment, and other clinic implementations that require accurate tumor phase information.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias Pulmonares , Algoritmos , Tomografia Computadorizada Quadridimensional , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Movimento (Física) , Imagens de Fantasmas , Análise de Componente Principal , Respiração
6.
J Appl Clin Med Phys ; 21(6): 53-62, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32227629

RESUMO

PURPOSE: The authors have previously shown the feasibility of using an artificial neural network (ANN) to eliminate the volume average effect (VAE) of scanning ionization chambers (ICs). The purpose of this work was to evaluate the method when applied to beams of different energies (6 and 10 MV) and modalities [flattened (FF) vs unflattened (FFF)], measured with ICs of various sizes. METHODS: The three-layer ANN extracted data from transverse photon beam profiles using a sliding window, and output deconvolved value corresponding to the location at the center of the window. Beam profiles of seven fields ranging from 2 × 2 to 10 × 10 cm2 at four depths (1.5, 5, 10 and 20 cm) were measured with three ICs (CC04, CC13, and FC65-P) and an EDGE diode detector for 6 MV FF and FFF. Similar data for the 10 MV FF beam was also collected with CC13 and EDGE. The EDGE-measured profiles were used as reference data to train and test the ANNs. Separate ANNs were trained by using the data of each beam energy and modality. Combined ANNs were also trained by combining data of different beam energies and/or modalities. The ANN's performance was quantified and compared by evaluating the penumbra width difference (PWD) between the deconvolved and reference profiles. RESULTS: Excellent agreement between the deconvolved and reference profiles was achieved with both separate and combined ANNs for all studied ICs, beam energies, beam modalities, and geometries. After deconvolution, the average PWD decreased from 1-3 mm to under 0.15 mm with separate ANNs and to under 0.20 mm with combined ANN. CONCLUSIONS: The ANN-based deconvolution method can be effectively applied to beams of different energies and modalities measured with ICs of various sizes. Separate ANNs yielded marginally better results than combined ANNs. An IC-specific, combined ANN can provide clinically acceptable results as long as the training data includes data of each beam energy and modality.


Assuntos
Redes Neurais de Computação , Aceleradores de Partículas , Radiometria , Humanos , Fótons , Doses de Radiação
7.
J Appl Clin Med Phys ; 21(3): 142-152, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32176453

RESUMO

Flattening filter free (FFF) linear accelerators produce a fluence distribution that is forward peaked. Various dosimetric benefits, such as increased dose rate, reduced leakage and out of field dose has led to the growth of FFF technology in the clinic. The literature has suggested the idea of vendors offering dedicated FFF units where the flattening filter (FF) is removed completely and manipulating the beam to deliver conventional flat radiotherapy treatments. This work aims to develop an effective way to deliver modulated flat beam treatments, rather than utilizing a physical FF. This novel optimization model is an extension of the direct leaf trajectory optimization (DLTO) previously developed for volumetric modulated radiation therapy (VMAT) and is capable of accounting for all machine and multileaf collimator (MLC) dynamic delivery constraints, using a combination of linear constraints and a convex objective function. Furthermore, the tongue and groove (T&G) effect was also incorporated directly into our model without introducing nonlinearity to the constraints, nor nonconvexity to the objective function. The overall beam flatness, machine deliverability, and treatment time efficiency were assessed. Regular square fields, including field sizes of 10 × 10 cm2 to 40 × 40 cm2 were analyzed, as well as three clinical fields, and three arbitrary contours with "concave" features. Quantitative flatness was measured for all modulated FFF fields, and the results were comparable or better than their open FF counterparts, with the majority having a quantitative flatness of less than 3.0%. The modulated FFF beams, due to the included efficiency constraint, were able to achieve acceptable delivery time compared to their open FF counterpart. The results indicated that the dose uniformity and flatness for the modulated FFF beams optimized with the DLTO model can successfully match the uniformity and flatness of their conventional FF counterparts, and may even provide further benefit by taking advantage of the unique FFF beam characteristics.


Assuntos
Modelos Estatísticos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Fótons , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/normas , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
8.
Sensors (Basel) ; 20(3)2020 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-32013016

RESUMO

As sensors become more prevalent in our lives, security issues have become a major concern. In the Advanced Persistent Threat (APT) attack, the sensor has also become an important role as a transmission medium. As a relatively weak link in the network transmission process, sensor networks often become the target of attackers. Due to the characteristics of low traffic, long attack time, diverse attack methods, and real-time evolution, existing detection methods have not been able to detect them comprehensively. Current research suggests that a suspicious domain name can be obtained by analyzing the domain name resolution (DNS) request to the target network in an APT attack. In past work based on DNS log analyses, most of the work would simply calculate the characteristics of the request message or the characteristics of the response message or the feature set of the request message plus the response message, and the relationship between the response message and the request message was not considered. This may leave out the detection of some APT attacks in which the DNS resolution process is incomplete. This paper proposes a new feature that represents the relationship between a DNS request and the response message, based on a deep learning method used to analyze the DNS request records. The algorithm performs threat assessment on the DNS behavior to be detected based on the calculated suspicious value. This paper uses the data of 4, 907, 147, 146 DNS request records (376, 605, 606 records after DNS Data Pre-processing) collected in a large campus network and uses simulation attack data to verify the validity and correctness of the system. The results of the experiments show that our method achieves an average accuracy of 97.6% in detecting suspicious DNS behavior, with the orange false positive (FP) at 2.3% and the recall at 96.8%. The proposed system can effectively detect the hidden and suspicious DNS behavior in APT.

9.
Med Dosim ; 45(3): 197-201, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31901300

RESUMO

The continuous delivery of volumetric modulated arc therapy (VMAT) plans is usually approximated by discrete apertures at evenly-spaced gantry angles for dose calculation purposes. This approximation can potentially lead to large dose calculation errors if the gantry angle spacings are large and/or there are large changes in the MLC apertures from one control point (CP) to the next. In this work, we developed a sliding-window (SW) method to improve VMAT dose calculation accuracy. For any 2 adjacent VMAT CPs ni and ni + 1, the dose distribution was approximated by a 2-CP SW IMRT beam with the starting MLC positions at CP ni and ending MLC positions at CP ni + 1, with the gantry angle fixed in the middle of the 2 VMAT CPs. Therefore, a VMAT beam with N CPs was approximated by a SW plan with N-1 SW beams. To validate the method, VMAT plans were generated for 10 patients in Pinnacle using 4° gantry spacing. Each plan was converted to a SW plan and dose was recalculated. Another VMAT plan, with 1° gantry spacing, was created by interpolating the original VMAT beam. The original plans were delivered on an Elekta Versa HD and measured with ArcCHECK. For both the isodose distribution and DVH, there were significant differences between the original VMAT plan and either the SW or the interpolated plan. However, they were indistinguishable between the SW and the interpolated plans. When compared with measurement, the average passing rates of the original VMAT plans were 87.3 ± 2.8% and 93.1 ± 1.0% for the 5 HN and 5 spine SBRT cases, respectively. On the other hand, the passing rates for both the VMAT1 and SW plans were above 95% for all the 10 cases studied. The dose calculation times of the original VMAT plans and the SW plans were very similar. We conclude that the proposed SW approach improves VMAT dose calculation accuracy without increase in dose calculation time.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Neoplasias da Coluna Vertebral/radioterapia , Humanos , Radiometria , Dosagem Radioterapêutica
10.
Med Phys ; 47(10): 4711-4720, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33460182

RESUMO

PURPOSE: Despite being the standard metric in patient-specific quality assurance (QA) for intensity-modulated radiotherapy (IMRT), gamma analysis has two shortcomings: (a) it lacks sensitivity to small but clinically relevant errors (b) it does not provide efficient means to classify the error sources. The purpose of this work is to propose a dual neural network method to achieve simultaneous error detection and classification in patient-specific IMRT QA. METHODS: For a pair of dose distributions, we extracted the dose difference histogram (DDH) for the low dose gradient region and two signed distance-to-agreement (sDTA) maps (one in x direction and one in y direction) for the high dose gradient region. An artificial neural network (ANN) and a convolutional neural network (CNN) were designed to analyze the DDH and the two sDTA maps, respectively. The ANN was trained to detect and classify six classes of dosimetric errors: incorrect multileaf collimator (MLC) transmission (±1%) and four types of monitor unit (MU) scaling errors (±1% and ±2%). The CNN was trained to detect and classify seven classes of spatial errors: incorrect effective source size, 1 mm MLC leaf bank overtravel or undertravel, 2 mm single MLC leaf overtravel or undertravel, and device misalignment errors (1 mm in x- or y direction). An in-house planar dose calculation software was used to simulate measurements with errors and noise introduced. Both networks were trained and validated with 13 IMRT plans (totaling 88 fields). A fivefold cross-validation technique was used to evaluate their accuracy. RESULTS: Distinct features were found in the DDH and the sDTA maps. The ANN perfectly identified all four types of MU scaling errors and the specific accuracies for the classes of no error, MLC transmission increase, MLC transmission decrease were 98.9%, 96.6%, and 94.3%, respectively. For the CNN, the largest confusion occurred between the 1-mm-MLC bank overtravel class and the 1-mm-device alignment error in x-direction class, which brought the specific accuracies down to 90.9% and 92.0%, respectively. The specific accuracy for the 2-mm-single MLC leaf undertravel class was 93.2% as it misclassified 5.7% of the class as being error free (false negative). Otherwise, the specific accuracy was above 95%. The overall accuracies across the fivefold were 98.3 ± 0.7% and 95.6% ± 1.5% for the ANN and the CNN, respectively. CONCLUSIONS: Both the DDH and the sDTA maps are suitable features for error classification in IMRT QA. The proposed dual neural network method achieved simultaneous error detection and classification with excellent accuracy. It could be used in complement with the gamma analysis to potentially shift the IMRT QA paradigm from passive pass/fail analysis to active error detection and root cause identification.


Assuntos
Radioterapia de Intensidade Modulada , Raios gama , Humanos , Redes Neurais de Computação , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
11.
J Appl Clin Med Phys ; 21(1): 43-52, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31737999

RESUMO

PURPOSE: Traditionally, the treatment couch coordinates (TCCs) for patients undergoing radiotherapy can only be determined at the time of treatment, placing pressure on the treating therapists and leaving several pathways for errors such as wrong-site treatment or wrong treatment table shift from a reference point. The purpose of this work is to propose an accurate, robust, and streamlined system that calculates TCC in advance. METHODS: The proposed system combines the advantages of two different calculation methods that use an indexed immobilization device. The first method uses an array of reference ball bearings (BBs) embedded in the CT scanner's couch-top. To obtain the patient-specific TCC, the spatial offset of the treatment planning isocenter from the reference BB is used. The second method performs a calculation using the one-to-one mapping relationship between the CT scanner's DICOM (Digital Imaging and Communications in Medicine) coordinate system and the TCC system. Both methods use a reference point in the CT coordinate system to correlate a point in the TCC system to perform the coordinate transfer between the two systems. Both methods were used to calculate the TCC and the results were checked against each other, creating an integrated workflow via automated self-checking. The accuracy of the calculation system was retrospectively evaluated with 275 patients, where the actual treatment position determined with cone-beam CT was used as a reference. RESULTS: An efficient workflow transparent to the therapists at both CT simulation and treatment was created. It works with any indexed immobilization device and can be universally applied to all treatment sites. The two methods had comparable accuracy, with 95% of the calculations within 3 mm. The inter-fraction variation was within ± 1.0 cm for 95% of the coordinates across all the treatment sites. CONCLUSIONS: A robust, accurate, and streamlined system was implemented to calculate TCCs in advance. It eases the pressure on the treating therapists, reduces patient setup time, and enhances the patient safety by preventing setup errors.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias/radioterapia , Posicionamento do Paciente/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Calibragem , Humanos , Dosagem Radioterapêutica , Estudos Retrospectivos
12.
Sensors (Basel) ; 19(14)2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-31330986

RESUMO

In recent years, sensors in the Internet of things have been commonly used in Human's life. APT (Advanced Persistent Threats) has caused serious damage to network security and the sensors play an important role in the attack process. For a long time, attackers infiltrate, attack, conceal, spread, and steal information of target groups through the compound use of various attacking means, while existing security measures based on single-time nodes cannot defend against such attacks. Attackers often exploit the sensors' vulnerabilities to attack targets because the security level of the sensors is relatively low when compared with that of the host. We can find APT attacks by checking the suspicious domains generated at different APT attack stages, since every APT attack has to use DNS to communicate. Although this method works, two challenges still exist: (1) the detection method needs to check a large scale of log data; (2) the small number of attacking samples limits conventional supervised learning. This paper proposes an APT detection framework AULD (Advanced Persistent Threats Unsupervised Learning Detection) to detect suspicious domains in APT attacks by using unsupervised learning. We extract ten important features from the host, domain name, and time from a large number of DNS log data. Later, we get the suspicious cluster by performing unsupervised learning. We put all of the domains in the cluster into the list of malicious domains. We collected 1,584,225,274 DNS records from our university network. The experiments show that AULD detected all of the attacking samples and that AULD can effectively detect the suspicious domain names in APT attacks.


Assuntos
Segurança Computacional , Software , Aprendizado de Máquina não Supervisionado , Algoritmos , Humanos
13.
Med Phys ; 45(12): 5586-5596, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30295949

RESUMO

PURPOSE: Ionization chambers are the detectors of choice for photon beam profile scanning. However, they introduce significant volume averaging effect (VAE) that can artificially broaden the penumbra width by 2-3 mm. The purpose of this study was to examine the feasibility of photon beam profile deconvolution (the elimination of VAE from ionization chamber-measured beam profiles) using a three-layer feedforward neural network. METHODS: Transverse beam profiles of photon fields between 2 × 2 and 10 × 10 cm2 were collected with both a CC13 ionization chamber and an EDGE diode detector on an Elekta Versa HD accelerator. These profiles were divided into three datasets (training, validation and test) to train and test a three-layer feedforward neural network. A sliding window was used to extract input data from the CC13-measured profiles. The neural network produced the deconvolved value at the center of the sliding window. The full deconvolved profile was obtained after the sliding window was moved over the measured profile from end to end. The EDGE-measured beam profiles were used as reference for the training, validation, and test. The number of input neurons, which equals the sliding window width, and the number of hidden neurons were optimized with a parametric sweeping method. A total of 135 neural networks were fully trained with the Levenberg-Marquardt backpropagation algorithm. The one with the best overall performance on the training and validation dataset was selected to test its generalization ability on the test dataset. The agreement between the neural network-deconvolved profiles and the EDGE-measured profiles was evaluated with two metrics: mean squared error (MSE) and penumbra width difference (PWD). RESULTS: Based on the two-dimensional MSE plots, the optimal combination of sliding window width of 15 and 5 hidden neurons was selected for the final neural network. Excellent agreement was achieved between the neural network-deconvolved profiles and the reference profiles in all three datasets. After deconvolution, the mean PWD reduced from 2.43 ± 0.26, 2.44 ± 0.36, and 2.46 ± 0.29 mm to 0.15 ± 0.15, 0.04 ± 0.03, and 0.14 ± 0.09 mm for the training, validation, and test dataset, respectively. CONCLUSIONS: We demonstrated the feasibility of photon beam profile deconvolution with a feedforward neural network in this work. The beam profiles deconvolved with a three-layer neural network had excellent agreement with diode-measured profiles.


Assuntos
Redes Neurais de Computação , Fótons , Estudos de Viabilidade , Radiometria
14.
J Med Chem ; 61(3): 1355-1374, 2018 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-29381358

RESUMO

The inhibition of hepatitis B virus (HBV) capsid assembly is a novel strategy for the development of chronic hepatitis B (CHB) therapeutics. On the basis of the preclinical properties and clinical results of GLS4, we carried out further investigation to seek a better candidate compound with appropriate anti-HBV potency, reduced hERG activity, decreased CYP enzyme induction, and improved pharmacokinetic (PK) properties. To this end, we have successfully found that morpholine carboxyl analogues with comparable anti-HBV activities to that of GLS4 showed decreased hERG activities, but they displayed strong CYP3A4 induction in a concentration-dependent manner, except for morpholine propionic acid analogues. After several rounds of modification, compound 58 (HEC72702), which had an (R)-morpholine-2-propionic acid at the C6 position of its dihydropyrimidine core ring, was found to display no induction of the CYP1A2, CYP3A4, or CYP2B6 enzyme at the high concentration of 10 µM. In particular, it demonstrated a good systemic exposure and high oral bioavailability and achieved a viral-load reduction greater than 2 log in a hydrodynamic-injected (HDI) HBV mouse model and has now been selected for further development.


Assuntos
Antivirais/farmacologia , Capsídeo/efeitos dos fármacos , Descoberta de Drogas , Vírus da Hepatite B/efeitos dos fármacos , Vírus da Hepatite B/metabolismo , Morfolinas/farmacologia , Propionatos/farmacologia , Pirimidinas/farmacologia , Tiazóis/farmacologia , Administração Oral , Animais , Antivirais/química , Antivirais/farmacocinética , Cães , Masculino , Simulação de Acoplamento Molecular , Morfolinas/química , Morfolinas/farmacocinética , Propionatos/química , Propionatos/farmacocinética , Conformação Proteica , Ratos , Estereoisomerismo , Tiazóis/química , Tiazóis/farmacocinética , Distribuição Tecidual
15.
Med Phys ; 44(11): 5627-5637, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28887827

RESUMO

PURPOSE: To propose a universal, parameterized gradient-based method (PGM) for radiation field size determination. METHODS: The PGM locates the beam profile's edge by parameterizing its penumbra region with a modified sigmoid function where the inflection point can be determined in a closed form. The parametrization was validated with filter-flattened (FF), flattening-filter-free (FFF) and wedged profiles measured on two Elekta linac models (Synergy and Versa HD). Gamma analysis with the delta dose function set to zero was used to quantitatively assess the parameterization accuracy. Field sizes of FF beams were calculated with the PGM and the full width at half maximum (FWHM) methods for comparison. To assess the consistency of the PGM and the FWHM method with geometric scaling across different depths, the calculated field size at a reference depth was scaled to other depths and compared with the field sizes calculated from the measured profiles. The method was also validated against a maximum-slope method (MSM) with wedge and FFF profiles. We also evaluated the robustness of the three methods with respect to measurement noise, varying scanning step sizes, detector characteristics, and beam energy/modality. RESULTS: Small distance-to-agreement (0.02 ± 0.02 mm) between the measured and parameterized penumbra region was observed for all profiles. The differences between the field sizes calculated with the FWHM method and the PGM were consistent (0.9 ± 0.3 mm), with the FWHM method yielding larger values. With geometrical scaling, the PGM and the FWHM method produced maximum differences of 0.26 and 1.16 mm, respectively. For wedge and FFF beams, the mean differences relative to FF fields were 0.15 ± 0.09 mm and 0.57 ± 0.91 mm for the PGM and the MSM, respectively. The PGM was also found to produce more consistent results than the FWHM method and the MSM when measurement noise, scanning step size, detector characteristics, and beam energy/modality changed. CONCLUSION: The proposed PGM is universally applicable to all beam modalities (FF, wedge and FFF) for accurate field size determination. Compared to the FWHM and the MSM, it is more robust to variations in measurement condition and detection system.


Assuntos
Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Desenho de Equipamento , Aceleradores de Partículas , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação
16.
Med Phys ; 44(6): 2096-2114, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28370002

RESUMO

PURPOSE: Most VMAT algorithms compute the dose on discretized apertures with small angular separations for practical reasons. However, machines deliver the VMAT dose with a continuously moving MLC and gantry and a continuously changing dose rate. The computed dose can deviate from the delivered dose, especially if no, or loose, MLC movement constraints are applied for the VMAT optimization. The goal of this paper is to establish a simplified mathematical model to analyze the discrepancy between the VMAT plan calculation dose and the delivered dose and to provide a reasonable solution for clinical implementation. METHODS: A simplified metric is first introduced to describe the discrepancy between doses computed with discretized apertures and a continuous delivery model. The delivery fluences were formed separately for six different leaf movement scenarios. The formula was then rewritten in a more general form. The correlation between discretized and continuous fluence is summarized using this general form. The Fourier analysis for the impacts from three separate factors - dose kernel width, aperture width, aperture distance - to the dose discrepancy is also presented in order to provide insight into the dose discrepancy caused by under-sampling in the frequency domain. Finally, a weighting-based interpolation (WBI) algorithm, which can improve the aperture interpolation efficiency, is proposed. The associated evaluation methods and criteria for the proposed algorithm are also given. RESULTS: The comparisons between the WBI algorithm and the equal angular interpolation (EAI) method suggested that the proposed algorithm has a great advantage with regard to aperture number efficiency. To achieve a 90% gamma passing rate using the dose computed with apertures generated with 0.5° EAI, with the initial optimization apertures as the standard for the comparison, the WBI needs only 66% and 54% of the aperture numbers that the EAI method needs for a 2° and a 4° angular separation of the VMAT optimization, respectively. The results also suggested that the weighted dose error index value, Θ, can be used as a stopping criterion for an interpolation algorithm, e.g., WBI or EAI, or as an indicator for sampling level evaluations. The phantom results indicate that the gamma passing rate decreases with increasing depth, from the phantom surface to the iso center, for the plans computed with under-sampled apertures. No obvious variation trends were observed for the plans computed with well-sampled apertures. CONCLUSIONS: The mathematical analysis suggests that the dose discrepancies due to under-sampling are strongly correlated with the aperture width, the distance between apertures, and the width of the dose kernel. The WBI algorithm proves to be an efficient aperture interpolation strategy and is useful for dose computation of VMAT plans.


Assuntos
Algoritmos , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Raios gama , Modelos Teóricos , Dosagem Radioterapêutica
17.
J Appl Clin Med Phys ; 18(2): 125-135, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28300374

RESUMO

The aim of this study is to perform a direct comparison of the source model for photon beams with and without flattening filter (FF) and to develop an efficient independent algorithm for planar dose calculation for FF-free (FFF) intensity-modulated radiotherapy (IMRT) quality assurance (QA). The source model consisted of a point source modeling the primary photons and extrafocal bivariate Gaussian functions modeling the head scatter, monitor chamber backscatter, and collimator exchange effect. The model parameters were obtained by minimizing the difference between the calculated and measured in-air output factors (Sc ). The fluence of IMRT beams was calculated from the source model using a backprojection and integration method. The off-axis ratio in FFF beams were modeled with a fourth degree polynomial. An analytical kernel consisting of the sum of three Gaussian functions was used to describe the dose deposition process. A convolution-based method was used to account for the ionization chamber volume averaging effect when commissioning the algorithm. The algorithm was validated by comparing the calculated planar dose distributions of FFF head-and-neck IMRT plans with measurements performed with a 2D diode array. Good agreement between the measured and calculated Sc was achieved for both FF beams (<0.25%) and FFF beams (<0.10%). The relative contribution of the head-scattered photons reduced by 34.7% for 6 MV and 49.3% for 10 MV due to the removal of the FF. Superior agreement between the calculated and measured dose distribution was also achieved for FFF IMRT. In the gamma comparison with a 2%/2 mm criterion, the average passing rate was 96.2 ± 1.9% for 6 MV FFF and 95.5 ± 2.6% for 10 MV FFF. The efficient independent planar dose calculation algorithm is easy to implement and can be valuable in FFF IMRT QA.


Assuntos
Algoritmos , Modelos Teóricos , Neoplasias/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Aceleradores de Partículas/instrumentação , Fótons , Dosagem Radioterapêutica
18.
Med Phys ; 43(9): 4996, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27587030

RESUMO

PURPOSE: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). METHODS: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. RESULTS: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. CONCLUSIONS: The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.


Assuntos
Equipamentos e Provisões Elétricas/normas , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído , Análise de Ondaletas , Artefatos , Controle de Qualidade
19.
Med Phys ; 43(5): 2081, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27147320

RESUMO

PURPOSE: To investigate the geometry dependence of the detector response function (DRF) of three commonly used scanning ionization chambers and its impact on a convolution-based method to address the volume averaging effect (VAE). METHODS: A convolution-based approach has been proposed recently to address the ionization chamber VAE. It simulates the VAE in the treatment planning system (TPS) by iteratively convolving the calculated beam profiles with the DRF while optimizing the beam model. Since the convolved and the measured profiles are subject to the same VAE, the calculated profiles match the implicit "real" ones when the optimization converges. Three DRFs (Gaussian, Lorentzian, and parabolic function) were used for three ionization chambers (CC04, CC13, and SNC125c) in this study. Geometry dependent/independent DRFs were obtained by minimizing the difference between the ionization chamber-measured profiles and the diode-measured profiles convolved with the DRFs. These DRFs were used to obtain eighteen beam models for a commercial TPS. Accuracy of the beam models were evaluated by assessing the 20%-80% penumbra width difference (PWD) between the computed and diode-measured beam profiles. RESULTS: The convolution-based approach was found to be effective for all three ionization chambers with significant improvement for all beam models. Up to 17% geometry dependence of the three DRFs was observed for the studied ionization chambers. With geometry dependent DRFs, the PWD was within 0.80 mm for the parabolic function and CC04 combination and within 0.50 mm for other combinations; with geometry independent DRFs, the PWD was within 1.00 mm for all cases. When using the Gaussian function as the DRF, accounting for geometry dependence led to marginal improvement (PWD < 0.20 mm) for CC04; the improvement ranged from 0.38 to 0.65 mm for CC13; for SNC125c, the improvement was slightly above 0.50 mm. CONCLUSIONS: Although all three DRFs were found adequate to represent the response of the studied ionization chambers, the Gaussian function was favored due to its superior overall performance. The geometry dependence of the DRFs can be significant for clinical applications involving small fields such as stereotactic radiotherapy.


Assuntos
Aceleradores de Partículas/instrumentação , Algoritmos , Modelos Teóricos , Doses de Radiação
20.
Med Phys ; 43(2): 748-60, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26843238

RESUMO

PURPOSE: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modeled data, (3) the quality assurance process of a linear accelerator's (Linac) beam characteristics, (4) the establishment of a standard data set for comparison with other data, etcetera. Parameterization of the photon beam dosimetry creates a data set that is portable and easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon beam dosimetric quantities, including percentage depth doses (PDDs), profiles, and total scatter output factors (S(cp)). METHODS: S(cp), PDDs, and profiles for different field sizes, depths, and energies were measured for a Linac using a cylindrical 3D water scanning system. All data were smoothed for the analysis and profile data were also centered, symmetrized, and geometrically scaled. The S(cp) data were analyzed using an exponential function. The inverse square factor was removed from the PDD data before modeling and the data were subsequently analyzed using exponential functions. For profile modeling, one halfside of the profile was divided into three regions described by exponential, sigmoid, and Gaussian equations. All of the analytical functions are field size, energy, depth, and, in the case of profiles, scan direction specific. The model's parameters were determined using the minimal amount of measured data necessary. The model's accuracy was evaluated via the calculation of absolute differences between the measured (processed) and calculated data in low gradient regions and distance-to-agreement analysis in high gradient regions. Finally, the results of dosimetric quantities obtained by the fitted models for a different machine were also assessed. RESULTS: All of the differences in the PDDs' buildup and the profiles' penumbra regions were less than 2 and 0.5 mm, respectively. The differences in the low gradient regions were 0.20% ± 0.20% (<1% for all) and 0.50% ± 0.35% (<1% for all) for PDDs and profiles, respectively. For S(cp) data, all of the absolute differences were less than 0.5%. CONCLUSIONS: This novel analytical model with minimum measurement requirements was proved to accurately calculate PDDs, profiles, and S(cp) for different field sizes, depths, and energies.


Assuntos
Aceleradores de Partículas , Fótons/uso terapêutico , Radiometria/instrumentação