Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Med Imaging ; 24(1): 126, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807064

RESUMO

BACKGROUND: Automated Breast Ultrasound (AB US) has shown good application value and prospects in breast disease screening and diagnosis. The aim of the study was to explore the ability of AB US to detect and diagnose mammographically Breast Imaging Reporting and Data System (BI-RADS) category 4 microcalcifications. METHODS: 575 pathologically confirmed mammographically BI-RADS category 4 microcalcifications from January 2017 to June 2021 were included. All patients also completed AB US examinations. Based on the final pathological results, analyzed and summarized the AB US image features, and compared the evaluation results with mammography, to explore the detection and diagnostic ability of AB US for these suspicious microcalcifications. RESULTS: 250 were finally confirmed as malignant and 325 were benign. Mammographic findings including microcalcifications morphology (61/80 with amorphous, coarse heterogeneous and fine pleomorphic, 13/14 with fine-linear or branching), calcification distribution (189/346 with grouped, 40/67 with linear and segmental), associated features (70/96 with asymmetric shadow), higher BI-RADS category with 4B (88/120) and 4 C (73/38) showed higher incidence in malignant lesions, and were the independent factors associated with malignant microcalcifications. 477 (477/575, 83.0%) microcalcifications were detected by AB US, including 223 malignant and 254 benign, with a significantly higher detection rate for malignant lesions (x2 = 12.20, P < 0.001). Logistic regression analysis showed microcalcifications with architectural distortion (odds ratio [OR] = 0.30, P = 0.014), with amorphous, coarse heterogeneous and fine pleomorphic morphology (OR = 3.15, P = 0.037), grouped (OR = 1.90, P = 0.017), liner and segmental distribution (OR = 8.93, P = 0.004) were the independent factors which could affect the detectability of AB US for microcalcifications. In AB US, malignant calcification was more frequent in a mass (104/154) or intraductal (20/32), and with ductal changes (30/41) or architectural distortion (58/68), especially with the both (12/12). BI-RADS category results also showed that AB US had higher sensitivity to malignant calcification than mammography (64.8% vs. 46.8%). CONCLUSIONS: AB US has good detectability for mammographically BI-RADS category 4 microcalcifications, especially for malignant lesions. Malignant calcification is more common in a mass and intraductal in AB US, and tend to associated with architectural distortion or duct changes. Also, AB US has higher sensitivity than mammography to malignant microcalcification, which is expected to become an effective supplementary examination method for breast microcalcifications, especially in dense breasts.


Assuntos
Neoplasias da Mama , Calcinose , Ultrassonografia Mamária , Humanos , Calcinose/diagnóstico por imagem , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Ultrassonografia Mamária/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Adulto , Idoso , Mamografia/métodos , Idoso de 80 Anos ou mais
2.
J Clin Ultrasound ; 51(6): 1039-1047, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37096417

RESUMO

PURPOSE: To investigate the efficiency and impact factors of anatomical intelligence for breast (AI-Breast) and hand-held ultrasound (HHUS) in lesion detection. METHODS: A total of 172 outpatient women were randomly selected, underwent AI-Breast ultrasound (Group AI) once and HHUS twice. HHUS was performed by breast imaging radiologists (Group A) and general radiologists (Group B). For the AI-Breast examination, a trained technician performed the whole-breast scan and data acquisition, while other general radiologists performed image interpretation. The examination time and lesion detection rate were recorded. The impact factors for breast lesion detection, including breast cup size, number of lesions, and benign or malignant lesions were analyzed. RESULTS: The detection rates of Group AI, A, and B were 92.8 ± 17.0%, 95.0 ± 13.6%, and 85.0 ± 22.9%, respectively. Comparable lesion detection rates were observed in Group AI and Group A (P > 0.05), but a significantly lower lesion detection rate was observed in Group B compared to the other two (both P < 0.05). Regarding missed diagnosis rates of malignant lesions, comparable performance was observed in Group AI, Group A, and Group B (8% vs. 4% vs. 14%, all P > 0.05). Scan times of Groups AI, A, and B were 262.15 ± 40.4 s, 237.5 ± 110.3 s, 281.2 ± 86.1 s, respectively. The scan time of Group AI was significantly higher than Group A (P < 0.01), but was slightly lower than Group B (P > 0.05). We found a strong linear correlation between scan time and cup size in Group AI (r = 0.745). No impacts of cup size and number of lesions were found on the lesion detection rate in Group AI (P > 0.05). CONCLUSIONS: With the assist of AI-Breast system, the lesion detection rate of AI-Breast ultrasound was comparable to that of a breast imaging radiologist and superior to that of the general radiologist. AI-Breast ultrasound may be used as a potential approach for breast lesions surveillance.


Assuntos
Neoplasias da Mama , Interpretação de Imagem Assistida por Computador , Feminino , Humanos , Sensibilidade e Especificidade , Interpretação de Imagem Assistida por Computador/métodos , Mama/diagnóstico por imagem , Mama/patologia , Ultrassonografia Mamária/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia
3.
Nat Commun ; 14(1): 788, 2023 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-36774357

RESUMO

Elastography ultrasound (EUS) imaging is a vital ultrasound imaging modality. The current use of EUS faces many challenges, such as vulnerability to subjective manipulation, echo signal attenuation, and unknown risks of elastic pressure in certain delicate tissues. The hardware requirement of EUS also hinders the trend of miniaturization of ultrasound equipment. Here we show a cost-efficient solution by designing a deep neural network to synthesize virtual EUS (V-EUS) from conventional B-mode images. A total of 4580 breast tumor cases were collected from 15 medical centers, including a main cohort with 2501 cases for model establishment, an external dataset with 1730 cases and a portable dataset with 349 cases for testing. In the task of differentiating benign and malignant breast tumors, there is no significant difference between V-EUS and real EUS on high-end ultrasound, while the diagnostic performance of pocket-sized ultrasound can be improved by about 5% after V-EUS is equipped.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Técnicas de Imagem por Elasticidade/métodos , Neoplasias da Mama/diagnóstico por imagem , Ultrassonografia , Endossonografia/métodos , Diagnóstico Diferencial , Sensibilidade e Especificidade
4.
Front Oncol ; 12: 830910, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35359391

RESUMO

Purpose: To develop a risk stratification system that can predict axillary lymph node (LN) metastasis in invasive breast cancer based on the combination of shear wave elastography (SWE) and conventional ultrasound. Materials and Methods: A total of 619 participants pathologically diagnosed with invasive breast cancer underwent breast ultrasound examinations were recruited from a multicenter of 17 hospitals in China from August 2016 to August 2017. Conventional ultrasound and SWE features were compared between positive and negative LN metastasis groups. The regression equation, the weighting, and the counting methods were used to predict axillary LN metastasis. The sensitivity, specificity, and the areas under the receiver operating characteristic curve (AUC) were calculated. Results: A significant difference was found in the Breast Imaging Reporting and Data System (BI-RADS) category, the "stiff rim" sign, minimum elastic modulus of the internal tumor and peritumor region of 3 mm between positive and negative LN groups (p < 0.05 for all). There was no significant difference in the diagnostic performance of the regression equation, the weighting, and the counting methods (p > 0.05 for all). Using the counting method, a 0-4 grade risk stratification system based on the four characteristics was established, which yielded an AUC of 0.656 (95% CI, 0.617-0.693, p < 0.001), a sensitivity of 54.60% (95% CI, 46.9%-62.1%), and a specificity of 68.99% (95% CI, 64.5%-73.3%) in predicting axillary LN metastasis. Conclusion: A 0-4 grade risk stratification system was developed based on SWE characteristics and BI-RADS categories, and this system has the potential to predict axillary LN metastases in invasive breast cancer.

5.
Front Oncol ; 11: 683263, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34568015

RESUMO

OBJECTIVE: The objective of this study was to evaluate the safety and efficacy of sirolimus (SRL) in the prevention of graft-versus-host disease (GVHD) in recipients following allogeneic hematopoietic stem cell transplantation (allo-HSCT). METHODS: Randomized controlled trials (RCTs) evaluating the safety and efficacy of SRL-based prophylaxis regimens in patients receiving allo-HSCT were obtained from PubMed, Embase, and the Cochrane database. Following specific inclusion and exclusion criteria, studies were selected and screened by two independent reviewers who subsequently extracted the study data. The Cochrane risk bias evaluation tool was used for quality evaluation, and RevMan 5.3 software was used for statistical analysis comparing the effects of SRL-based and non-SRL-based regimens on acute GVHD, chronic GVHD, overall survival (OS), relapse rate, non-relapse mortality (NRM), thrombotic microangiopathy (TMA), and veno-occlusive disease (VOD). RESULTS: Seven studies were included in this meta-analysis, with a total sample size of 1,673 cases, including 778 cases of patients receiving SRL-based regimens and 895 cases in which patients received non-SRL-based regimens. Our data revealed that SRL containing prophylaxis can effectively reduce the incidence of grade II-IV acute GVHD (RR = 0.75, 95% CI: 0.68∼0.82, p < 0.0001). SRL-based prophylaxis was not associated with an improvement of grade III-IV acute GVHD (RR = 0.78, 95% CI: 0.59∼1.03, p = 0.08), chronic GVHD (p = 0.89), OS (p = 0.98), and relapse rate (p = 0.16). Despite its immunosuppressant effects, SRL-based regimens did not increase bacterial (p = 0.68), fungal (p = 0.70), or CMV (p = 0.10) infections. However, patients receiving SRL-based regimens had increased TMA (p < 0.00001) and VOD (p < 0.00001). CONCLUSIONS: This meta-analysis indicates that addition of sirolimus is an effective alternative prophylaxis strategy for II-IV aGVHD but may cause endothelial cell injury and result in secondary TMA or VOD events.

6.
Front Med (Lausanne) ; 7: 110, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32296709

RESUMO

Immune thrombocytopenia (ITP) is an autoimmune disease which arises due to self-destruction of circulating platelets. Failure to respond or maintain a response to first-line treatment can lead to refractory/relapsed (R/R) ITP. The mechanism remains complicated and lacks a standard clinical treatment. Sirolimus (SRL) is a mammalian target of rapamycin (mTOR) inhibitor that has been demonstrated to inhibit lymphocyte activity, indicating potential for SRL in treatment of ITP. Activation of the mTOR pathway in autoimmune diseases suggests that SRL might be a useful agent for treating ITP. Accordingly, we initiated an open-label, prospective clinical trial using SRL for patients with R/R ITP (ChiCTR-ONC-17012126). The trial enrolled 86 patients, each dosed with 2-4 mg/day of SRL. By the third month, 40% of patients (34 of 86) achieved complete remission (CR) and 45% of patients (39 of 86) achieved partial remission (PR), whereby establishing an overall response rate (ORR) of 85%. By 6 months of treatment, 41% of patients (32 of 78) achieved CR and 29% of patients (23 of 78) achieved PR, establishing an ORR of 70% without serious side effects. After 12 months follow-up, the ORR remained at 65%. We also found that SRL treatment exhibited higher efficacy in achieving CR in ITP patients who were younger than 40 years old or steroid dependent by univariate analysis. Importantly, in patients who responded, SRL treatment was associated with a reduction in the percentage of Th2, Th17 cells, and increase in the percentage of M-MDSCs and Tregs, indicating that SRL may reestablish peripheral tolerance. Taken together, Sirolimus demonstrated efficacy as a second-line agent for R/R ITP.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...