1.
PLoS One ; 7(11): e49936, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23209622

RESUMO

BACKGROUND: Dose continues to be an area of concern in preclinical imaging studies, especially for those imaging disease progression in longitudinal studies. To our knowledge, this work is the first to characterize and assess dose from the Inveon CT imaging platform using nanoDot dosimeters. This work is also the first to characterize a new low-dose configuration available for this platform. METHODOLOGY/PRINCIPAL FINDINGS: nanoDot dosimeters from Landauer, Inc. were surgically implanted into 15 wild type mice. Two nanoDots were placed in each animal: one just under the skin behind the spine and the other located centrally within the abdomen. A manufacturer-recommended CT protocol was created with 1 projection per degree of rotation acquired over 360 degrees. For best comparison of the low dose and standard configurations, noise characteristics of the reconstructed images were used to match the acquisition protocol parameters. Results for all dose measurements showed the average dose delivered to the abdomen to be 13.8 cGy±0.74 and 0.97 cGy±0.05 for standard and low dose configurations respectively. Skin measurements of dose averaged 15.99 cGy±0.72 and 1.18 cGy±0.06. For both groups, the standard deviation to mean was less than 5.6%. The maximum dose received for the abdomen was 15.12 cGy and 0.97 cGy while the maximum dose for the skin was 17.3 cGy and 1.32 cGy. Control dosimeters were used for each group to validate that no unwanted additional radiation was present to bias the results. CONCLUSIONS/SIGNIFICANCE: This study shows that the Inveon CT platform is suitable for imaging mice both for single and longitudinal studies. Use of low-dose detector hardware results in significant reductions in dose to subjects with a >12x (90%) reduction in delivered dose. Installation of this hardware on another in vivo microCT platform resulted in dose reductions of over 9x (89%).


Assuntos
Doses de Radiação , Radiometria , Microtomografia por Raio-X/métodos , Animais , Processamento de Imagem Assistida por Computador , Camundongos , Microtomografia por Raio-X/instrumentação
2.
Phys Med Biol ; 57(24): 8135-52, 2012 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-23171509

RESUMO

The work presented herein describes the system design and performance evaluation of a miniaturized near-infrared fluorescence (NIRF) frequency-domain photon migration (FDPM) system with non-contact excitation and homodyne detection capability for small animal fluorescence tomography. The FDPM system was developed specifically for incorporation into a Siemens micro positron emission tomography/computed tomography (microPET/CT) commercial scanner for hybrid small animal imaging, but could be adapted to other systems. Operating at 100 MHz, the system noise was minimized and the associated amplitude and phase errors were characterized to be ±0.7% and ±0.3°, respectively. To demonstrate the tomographic ability, a commercial mouse-shaped phantom with 50 µM IRDye800CW and 68Ga containing inclusion was used to associate PET and NIRF tomography. Three-dimensional mesh generation and anatomical referencing was accomplished through CT. A third-order simplified spherical harmonics approximation (SP3) algorithm, for efficient prediction of light propagation in small animals, was tailored to incorporate the FDPM approach. Finally, the PET-NIRF target co-localization accuracy was analyzed in vivo with a dual-labeled imaging agent targeting orthotopic growth of human prostate cancer. The obtained results validate the integration of time-dependent fluorescence tomography system within a commercial microPET/CT scanner for multimodality small animal imaging.


Assuntos
Imagem Multimodal/instrumentação , Fótons , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Animais , Linhagem Celular Tumoral , Transformação Celular Neoplásica , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Camundongos , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Ondas de Rádio , Espectrometria de Fluorescência
3.
J Biomed Opt ; 14(5): 054014, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19895116

RESUMO

Ovarian cancer has the highest mortality of all gynecologic cancers, with a five-year survival rate of only 30% or less. Current imaging techniques are limited in sensitivity and specificity in detecting early stage ovarian cancer prior to its widespread metastasis. New imaging techniques that can provide functional and molecular contrasts are needed to reduce the high mortality of this disease. One such promising technique is photoacoustic imaging. We develop a 1280-element coregistered 3-D ultrasound and photoacoustic imaging system based on a 1.75-D acoustic array. Volumetric images over a scan range of 80 deg in azimuth and 20 deg in elevation can be achieved in minutes. The system has been used to image normal porcine ovarian tissue. This is an important step toward better understanding of ovarian cancer optical properties obtained with photoacoustic techniques. To the best of our knowledge, such data are not available in the literature. We present characterization measurements of the system and compare coregistered ultrasound and photoacoustic images of ovarian tissue to histological images. The results show excellent coregistration of ultrasound and photoacoustic images. Strong optical absorption from vasculature, especially highly vascularized corpora lutea and low absorption from follicles, is demonstrated.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Neoplasias Ovarianas/diagnóstico por imagem , Ovário/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Técnica de Subtração , Algoritmos , Animais , Técnicas de Imagem por Elasticidade/instrumentação , Feminino , Aumento da Imagem/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
4.
Opt Express ; 17(9): 7245-58, 2009 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-19399101

RESUMO

A novel prototype intraoperative system combining positron detection and optical coherence tomography (OCT) imaging has been developed for early ovarian cancer detection. The probe employs eight plastic scintillating fiber tips for preferential detection of local positron activity surrounding a central scanning OCT fiber providing volumetric imaging of tissue structure in regions of high radiotracer uptake. Characterization measurements of positron sensitivity, spatial response, and position mapping are presented for Tl(204)/Cs(137) sources as well as 18F-FDG. In conjunction with co-registered frequency domain OCT measurements the results demonstrate the potential for a miniaturized laparoscopic probe offering simultaneous functional localization and structural imaging for improved early cancer detection.


Assuntos
Aumento da Imagem/instrumentação , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/cirurgia , Tomografia por Emissão de Pósitrons/instrumentação , Cirurgia Assistida por Computador/instrumentação , Tomografia de Coerência Óptica/instrumentação , Transdutores , Estudos de Viabilidade , Feminino , Humanos , Projetos Piloto , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos
5.
J Biomed Opt ; 9(3): 454-63, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15189082

RESUMO

We present a real-time data-processing and display unit based on a custom-designed digital signal processor (DSP) module for imaging tissue structure and Doppler blood flow. The DSP module is incorporated into a conventional optical coherence tomography system. We also demonstrate the flexibility of embedding advanced Doppler processing algorithms in the DSP module. Two advanced velocity estimation algorithms previously introduced by us are incorporated in this DSP module. Experiments on Intralipid flow demonstrate that a pulsatile flow of several hundred pulses per minute can be faithfully captured in M-scan mode by this DSP system. In vivo imaging of a rat's abdominal blood flow is also presented.


Assuntos
Abdome/irrigação sanguínea , Abdome/fisiologia , Algoritmos , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Fluxometria por Laser-Doppler/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Tomografia Óptica/instrumentação , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fluxometria por Laser-Doppler/métodos , Sistemas On-Line , Imagens de Fantasmas , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Óptica/métodos , Interface Usuário-Computador