Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiothorac Surg ; 19(1): 211, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38616249

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become widely used in recent years, However, there is also an increasing need for removal of TAVR valves due to prosthetic valve dysfunction (PVD) and the development of infective endocarditis. Surgical aortic valve replacement (AVR) for these patients is risky due to the original patient background and anatomic conditions. Intuity rapid deployment aortic valve (Edwards Lifesciences, Irvine, CA) replacement would be useful for such high risk patients to prevent longer cardiac arrest time and obtain good hemodynamic results. However, there are few reports which present Intuity valve replacement after TAVR explantation. Herein, We report two cases in which we have achieved good hemodynamics with shorter cardiac arrest times by using a rapid deployment valve after TAVR explantation. CASE PRESENTATION: We present 2 cases of successful implantation of the Intuity rapid deployment valve after TAVR explantation. The 84- and 88-year-old female patients had previously received TAVR for severe aortic stenosis with SAPIEN XT (Edwards Lifesciences, Irvine, CA) and developed PVD during follow-up. The TAVR valve was removed carefully, then an Intuity valve was implanted with cardiac arrest times of 69 and 41 min. Both patients had good echocardiographic results with effective orifice area of 2.0 cm2 and 1.2 cm2 and mean trans-aortic plessure gradient of 9 mmHg and 15 mmHg respectively without aortic regurgitation. They were discharged without major complications. CONCLUSIONS: Surgical AVR using a rapid deployment valve is a useful alternative to sutured AVR after TAVR valve explantation. It allows for shorter cardiac arrest times and better postoperative hemodynamics without major complication.


Assuntos
Insuficiência da Valva Aórtica , Parada Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Remoção de Dispositivo
3.
Transfusion ; 63(6): 1250-1254, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37129363

RESUMO

BACKGROUND: Hepatitis B virus (HBV)-positive individuals with isolated anti-HBs are found among HBV vaccine recipients and healthy blood donors with no vaccination history. HBV infectivity from blood transfusions derived from such individuals remains unclear. CASE PRESENTATION: A male patient who received transfusion with blood negative for individual donation-NAT, HBsAg and anti-HBc but weakly positive for anti-HBs developed typical transfusion-transmitted (TT)-HBV with anti-HBc response. The responsible blood donor was a frequent repeat donor showing a marked increase in anti-HBs titer without anti-HBc response 84 days after index donation. Test results for his past donations showed transient viremia with very low viral load and fluctuating low-level anti-HBs. The HBV vaccination history of this donor was unknown. DISCUSSION: Anti-HBs and anti-HBc kinetics of the donor suggest a second antibody response to new HBV challenge, representing a vaccine breakthrough case. On the other hand, transient low-level viremia and fluctuating anti-HBs in the test results of past donations suggested chronic occult HBV infection with isolated anti-HBs. CONCLUSION: Whatever the basic infection state, blood donors with isolated weak anti-HBs may include a small population with a risk of causing TT-HBV. Identifying individuals harboring such TT-HBV risk among individuals positive only for anti-HBs is difficult under current screening strategies. Active surveillance for the occurrence of TT-HBV with blood positive only for anti-HBs is necessary.


Assuntos
Hepatite B Crônica , Hepatite B , Humanos , Masculino , Vírus da Hepatite B/genética , Viremia , Anticorpos Anti-Hepatite B , Antígenos de Superfície da Hepatite B , Antígenos do Núcleo do Vírus da Hepatite B , Vacinas contra Hepatite B , Doadores de Sangue , DNA Viral
4.
J Artif Organs ; 26(2): 151-155, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35906510

RESUMO

Implantation of left ventricular assist device (LVAD) for arrhythmogenic right ventricular (RV) cardiomyopathy is challenging associated with small LV cavity, laterally dislocated LV apex, thin and fragile RV free wall. A 43-year-old male with more than 10 years of medical treatment developed congestive heart failure related to biventricular failure. Durable LVAD was indicated to prevent further deterioration of the RV function, which would be exacerbated by progression of LV dysfunction. To simulate surgery, we printed-out a 3D heart model based on enhanced CT scanning study to identify the optimal coring position in the LV apex, by which the inflow directs the mitral valve. We then found that the mini-cuff of the HeartMate3 should be fixed in the paper-thin RV free wall by the usual cuff-sewing method. In the surgery, after the coring as planned, 5 pairs of interrupted sutures on the medial side were passed from the luminal side of the LV and then to the mini-cuff, and the lateral side of the mini-cuff was fixed with a continuous sutures, not to sew into the RV wall. The surgery was completed without complications with a good hemodynamics. The 3D heart model facilitated this unique method, indicating a usefulness of printed-out heart model for cases with unusual cardiac anatomy, which needs implantation of durable LVAD.


Assuntos
Displasia Arritmogênica Ventricular Direita , Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Esquerda , Disfunção Ventricular Direita , Masculino , Humanos , Adulto , Displasia Arritmogênica Ventricular Direita/cirurgia , Displasia Arritmogênica Ventricular Direita/complicações , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Disfunção Ventricular Esquerda/complicações , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Disfunção Ventricular Direita/etiologia , Função Ventricular Direita
5.
Circ J ; 86(12): 1961-1967, 2022 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-36273915

RESUMO

BACKGROUND: The superiority of a fully magnetically levitated centrifugal-flow left ventricular assist device (LVAD) in terms of overall survival, stroke events and pump thrombosis has been demonstrated in previous international analyses, so we evaluated a Japanese cohort for the same.Methods and Results: This retrospective observational study was conducted at Osaka University Medical Hospital and the National Cerebral and Cardiovascular Center in Japan. A total of 75 consecutive patients who underwent HeartMate3 (HM3) implantation were included. The primary endpoint was on-device survival, and the secondary endpoint was the incidence of LVAD-related complications at 2 years. All parameters were compared with those of the previously performed HeartMate II (HMII) implantation in 197 cases. The on-device survival rates were 94.7% and 92.3% in the HM3 and HMII groups, respectively, at the 2-year follow-up (P=0.62). The rehospitalization-free rate after implantation was 61.8% in the HM3 group, which was significantly higher than that in the HMII group (relative risk, 0.35; 95% confidence interval [CI], 0.23-0.55; P<0.0001). Event-free survival rates from cerebral cerebrovascular events and pump thrombosis in the HM3 group were significantly higher than those in the HMII group, at 97.2% and 100%, respectively (relative risk, 0.14; 95% CI 0.03-0.58); P=0.0015 and relative risk, not calculated; P=0.049, respectively). CONCLUSIONS: Satisfactory short-term outcomes were observed after HM3 implantation in a Japanese cohort.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Trombose , Humanos , Coração Auxiliar/efeitos adversos , Japão/epidemiologia , Acidente Vascular Cerebral/complicações , Trombose/etiologia , Estudos Retrospectivos , Resultado do Tratamento
6.
J Cardiol Cases ; 25(2): 87-90, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35079305

RESUMO

Left ventricular (LV) pseudoaneurysm is a rare complication after postinfarction repair of ventricular septal rupture (VSR), and surgical treatment of this condition due to mycosis has rarely been reported. We report a rare case of successful surgical treatment of delayed LV pseudoaneurysm related to Candida albicans infection after repair of VSR due to myocardial infarction. A 75-year-old woman was admitted for fever and severe inflammatory reaction. Two and a half years previously, she had undergone postinfarct VSR repair and was treated for mycotic infective endocarditis due to C. albicans. Transthoracic echocardiography and computed tomography revealed a LV pseudoaneurysm (maximum transverse diameter 6.2 cm). The cause of the LV pseudoaneurysm was suspected to be infectious, and broad-spectrum antibiotic treatment was started. Fourteen days after admission, she developed acute abdominal pain and an elevated ß-D-glucan level because the LV pseudoaneurysm ruptured. Emergency surgical treatment was performed with antimycotic drug therapy. The LV wall defect was reconstructed using bovine pericardium under cardiopulmonary support. Her postoperative course was good, and she was discharged to home. Echocardiography revealed no recurrence of the LV pseudoaneurysm at 4 months postoperatively. During 1 year of follow-up, the patient had been doing well without any infection or adverse event. .

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...