Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
VideoGIE ; 9(5): 243-246, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766401

RESUMO

Video 1Pancreatic stent removal with a novel drill dilator.

3.
Clin Endosc ; 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38549245

RESUMO

Background/Aims: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) performed at the intrahepatic bile duct segment 3 (B3) is widely used for biliary drainage. Although performing post-puncture procedures is easier in the intrahepatic bile duct segment 2 (B2) when using a conventional oblique-viewing (OV) EUS scope, this method may cause transesophageal puncture and severe adverse events. We evaluated the safety and efficacy of B2 puncture using a novel OV-EUS scope. Methods: In this single-center retrospective study, we prospectively enrolled and collected data from 45 patients who consecutively underwent EUS-HGS procedures with a novel OV-EUS scope between September 2021 and December 2022 at our cancer center. Results: The technical success rates of B2-EUS-HGS and EUS-HGS were 93.3% (42/45) and 97.8% (44/45), respectively. The early adverse event rate was 8.9% (4/45) with no cases of scope changes or transesophageal punctures. The median procedure time was 13 minutes (range, 5-30). Conclusions: B2-EUS-HGS can be performed safely with the novel EG-740UT (Fujifilm) OV-scope without transesophageal puncture and with a high success rate. B2-EUS-HGS using this novel OV scope may be the preferred strategy for EUS-HGS.

4.
Clin Endosc ; 57(3): 384-392, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38356172

RESUMO

BACKGROUND/AIMS: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is a standard diagnostic method for biliary tract cancer (BTC), and samples obtained in this manner may be used for comprehensive genomic profiling (CGP). This study evaluated the utility of EUS-TA for CGP in a clinical setting and determined the factors associated with the adequacy of CGP in patients with BTC. METHODS: CGP was attempted for 105 samples from 94 patients with BTC at the Aichi Cancer Center, Japan, from October 2019 to April 2022. RESULTS: Overall, 77.1% (81/105) of the samples were adequate for CGP. For 22-G or 19-G fine-needle biopsy (FNB), the sample adequacy was 85.7% (36/42), which was similar to that of surgical specimens (94%, p=0.45). Univariate analysis revealed that 22-G or larger FNB needle usage (86%, p=0.003), the target primary lesions (88%, p=0.015), a target size ≥30 mm (100%, p=0.0013), and number of punctures (90%, p=0.016) were significantly positively associated with CGP sample adequacy. CONCLUSIONS: EUS-TA is useful for CGP tissue sampling in patients with BTC. In particular, the use of 22-G or larger FNB needles may allow for specimen adequacy comparable to that of surgical specimens.

5.
Clin Endosc ; 57(1): 122-127, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37190745

RESUMO

Benign biliary stricture (BBS) is a complication of chronic pancreatitis (CP). Despite endoscopic biliary stenting, some patients do not respond to treatment, and they experience recurrent cholangitis. We report two cases of CP with refractory BBS treated using endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) fistula creation. A 50-year-old woman and a 60-year-old man both presented with obstructive jaundice secondary to BBS due to alcoholic CP. They underwent repeated placement of a fully covered self-expandable metal stent for biliary strictures. However, the strictures persisted, causing repeated episodes of cholangitis. Therefore, an EUS-CDS was performed. The stents were eventually removed and the patients became stent-free. These fistulas have remained patent without cholangitis for more than 2.5 years. Fistula creation using EUS-CDS is an effective treatment option for BBS.

6.
Dig Endosc ; 36(2): 206-214, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37186389

RESUMO

OBJECTIVES: Endoscopic ultrasound-guided fine-needle aspiration and fine-needle biopsy (EUS-FNA/FNB) is not fully established as a pathological sampling tool for gallbladder lesions due to limited evidence. We therefore aimed to clarify the effectiveness and safety of this procedure in a large-population cohort. METHODS: This study retrospectively evaluated the diagnostic yield of EUS-FNA/FNB for accurately differentiating between benign and malignant gallbladder lesions. Puncture targets included the gallbladder mass, lymph node, and liver mass. Adverse events and factors associated with diagnostic accuracy were analyzed as well. RESULTS: In 187 patients with gallbladder lesions undergoing EUS-FNA/FNB, 18 benign lesions and 169 malignant lesions were identified. Overall sampling adequacy was 98% (184/187). The diagnostic accuracy of EUS-FNA/FNB was 97% (182/187), sensitivity was 97% (164/169), and specificity was 100% (18/18). A single postprocedural complication (minor bleeding) was recorded in one patient. In the 169 cases of malignancy, 203 sites were punctured for pathological sampling of the primary mass (n = 94), lymph node (n = 79), and metastatic liver mass (n = 30). No significant difference was found for diagnostic accuracy among the puncture sites (P = 0.70). In cases having specimens obtained from the primary mass, the accuracy of those targeting liver invasion sites was significantly higher than that of other sites (98% vs. 83%, P < 0.01). CONCLUSION: EUS-FNA/FNB demonstrated clinical usefulness and safety for the pathological diagnosis of gallbladder lesions, with high diagnostic yield and a low incidence of adverse events. Targeting the site of liver infiltration may improve the diagnostic rate of EUS-FNA/FNB in the primary mass.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pancreáticas , Humanos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Vesícula Biliar/patologia , Estudos Retrospectivos , Neoplasias Pancreáticas/patologia
7.
Clin Endosc ; 57(2): 246-252, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37743069

RESUMO

BACKGROUND/AIMS: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) is useful for patients with biliary cannulation failure or inaccessible papillae. However, it can lead to serious complications such as bile peritonitis in patients with ascites; therefore, development of a safe method to perform EUS-HGS is important. Herein, we evaluated the safety of EUS-HGS with continuous ascitic fluid drainage in patients with ascites. METHODS: Patients with moderate or severe ascites who underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after the procedure at our institution between April 2015 and December 2022, were included in the study. We evaluated the technical and clinical success rates, EUS-HGS-related complications, and feasibility of re-intervention. RESULTS: Ten patients underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after completion of the procedure. Median duration of ascites drainage before and after EUS-HGS was 2 and 4 days, respectively. Technical success with EUS-HGS was achieved in all 10 patients (100%). Clinical success with EUS-HGS was achieved in 9 of the 10 patients (90 %). No endoscopic complications such as bile peritonitis were observed. CONCLUSION: In patients with ascites, continuous ascites drainage, which is initiated before EUS-HGS and terminated after completion of the procedure, may prevent complications and allow safe performance of EUS-HGS.

8.
Clin Endosc ; 2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37743070

RESUMO

Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is a highly accurate method for diagnosing pancreatic neuroendocrine tumors (PNETs); however, some PNETs are difficult to diagnose. Recently, the efficacy of needle-based confocal laser endomicroscopy (nCLE) in diagnosing solid pancreatic masses has been reported. However, the efficacy of nCLE in the diagnosis of PNETs remains unknown and only a small number of cases have been reported. Hence, this study aimed to evaluate the efficacy of nCLE in the diagnosis of PNETs. Methods: This single-center retrospective study evaluated 30 consecutive patients with suspected PNETs on contrast-enhanced computed tomography, who consented to nCLE combined with EUS-FNA and were diagnosed using EUS-FNA or surgical resection. The diagnostic criteria for PNETs using nCLE were based on the nesting and trabecular and glandular arrangement of tumor cell clusters surrounded by capillary vessels and fibrosis, as reported in previous studies. Results: The diagnosis using nCLE was classified into three categories: misdiagnosis in three cases (10%), non-diagnostic in six cases (20%), and diagnostic in 21 cases (70%). nCLE was able to diagnose PNET in one of the two cases with inconclusive EUS-FNA. Conclusions: Although further development of the resolution and optimization of the diagnostic criteria are required, nCLE may constitute a useful diagnostic option in cases of inconclusive EUS-FNA for PNETs.

10.
Clin Endosc ; 56(4): 490-498, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37157966

RESUMO

BACKGROUND/AIMS: Post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) is the most common and serious complication of endoscopic retrograde cholangiopancreatography. To prevent this event, a unique precutting method, termed opening window fistulotomy, was performed in patients with a large infundibulum as the primary procedure for biliary cannulation, whereby a suprapapillary laid-down H-shaped incision was made without touching the orifice. This study aimed to assess the safety and feasibility of this novel technique. METHODS: One hundred and ten patients were prospectively enrolled in this study. Patients with a papillary roof size ≥10 mm underwent opening window fistulotomy for primary biliary access. In addition, the incidence of complications and success rate of biliary cannulation were evaluated. RESULTS: The median size of the papillary roof was 6 mm (range, 3-20 mm). Opening window fistulotomy was performed in 30 patients (27.3%), none of whom displayed PEP. Duodenal perforation was recorded in one patient (3.3%), which was resolved by conservative treatment. The cannulation rate was high (96.7%, 29/30 patients). The median duration of biliary access was 8 minutes (range, 3-15 minutes). CONCLUSION: Opening window fistulotomy demonstrated its feasibility for primary biliary access by achieving great safety with no PEP complications and a high success rate for biliary cannulation.

11.
Clin Endosc ; 56(2): 221-228, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36879539

RESUMO

BACKGROUND/AIMS: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is essential for the diagnosis of pancreatic cancer. The feasibility of comprehensive genomic profiling (CGP) using samples obtained by EUS-TA has been under recent discussion. This study aimed to evaluate the utility of EUS-TA for CGP in a clinical setting. METHODS: CGP was attempted in 178 samples obtained from 151 consecutive patients with pancreatic cancer at the Aichi Cancer Center between October 2019 and September 2021. We evaluated the adequacy of the samples for CGP and determined the factors associated with the adequacy of the samples obtained by EUS-TA retrospectively. RESULTS: The overall adequacy for CGP was 65.2% (116/178), which was significantly different among the four sampling methods (EUS-TA vs. surgical specimen vs. percutaneous biopsy vs. duodenal biopsy, 56.0% [61/109] vs. 80.4% [41/51] vs. 76.5% [13/17] vs. 100.0% [1/1], respectively; p=0.022). In a univariate analysis, needle gauge/type was associated with adequacy (22 G fine-needle aspiration vs. 22 G fine-needle biopsy [FNB] vs. 19 G-FNB, 33.3% (5/15) vs. 53.5% (23/43) vs. 72.5% (29/40); p=0.022). The sample adequacy of 19 G-FNB for CGP was 72.5% (29/40), and there was no significant difference between 19 G-FNB and surgical specimens (p=0.375). CONCLUSION: To obtain adequate samples for CGP with EUS-TA, 19 G-FNB was shown to be the best in clinical practice. However, 19 G-FNB was not still sufficient, so further efforts are required to improve adequacy for CGP.

12.
Clin Endosc ; 56(3): 367-374, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36600657

RESUMO

BACKGROUND/AIMS: Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) using oblique-view EUS in patients with a surgically altered anatomy (SAA) of the upper gastrointestinal tract is limited because of difficult scope insertion due to the disturbed anatomy. This study aimed to investigate the efficiency of forward-view (FV)-EUS in performing FNA in patients with a SAA. METHODS: We retrospectively investigated 32 patients with a SAA of the upper gastrointestinal tract who visited Aichi Cancer Center Hospital in Nagoya, Japan, between January 2014 and December 2020. We performed-upper gastrointestinal EUS-FNA using FV-EUS combined with fluoroscopic imaging to confirm tumor recurrence or to make a decision before chemotherapy or after a failure of diagnosis by radiology. RESULTS: We successfully performed EUS-FNA in all studied patients (100% technical success), with the specificity, sensitivity, and accuracy of 100%, 87.5%, and 87.8%, respectively, with no complications. CONCLUSION: EUS-FNA using FV-EUS combined with fluoroscopic imaging is an effective and safe technique for tissue acquisition in patients with a SAA.

14.
Endoscopy ; 55(2): 140-149, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35688454

RESUMO

BACKGROUND : There are several types of pancreatic mass, so it is important to distinguish between them before treatment. Artificial intelligence (AI) is a mathematical technique that automates learning and recognition of data patterns. This study aimed to investigate the efficacy of our AI model using endoscopic ultrasonography (EUS) images of multiple types of pancreatic mass (pancreatic ductal adenocarcinoma [PDAC], pancreatic adenosquamous carcinoma [PASC], acinar cell carcinoma [ACC], metastatic pancreatic tumor [MPT], neuroendocrine carcinoma [NEC], neuroendocrine tumor [NET], solid pseudopapillary neoplasm [SPN], chronic pancreatitis, and autoimmune pancreatitis [AIP]). METHODS : Patients who underwent EUS were included in this retrospective study. The included patients were divided into training, validation, and test cohorts. Using these cohorts, an AI model that can distinguish pancreatic carcinomas from noncarcinomatous pancreatic lesions was developed using a deep-learning architecture and the diagnostic performance of the AI model was evaluated. RESULTS : 22 000 images were generated from 933 patients. The area under the curve, sensitivity, specificity, and accuracy (95 %CI) of the AI model for the diagnosis of pancreatic carcinomas in the test cohort were 0.90 (0.84-0.97), 0.94 (0.88-0.98), 0.82 (0.68-0.92), and 0.91 (0.85-0.95), respectively. The per-category sensitivities (95 %CI) of each disease were PDAC 0.96 (0.90-0.99), PASC 1.00 (0.05-1.00), ACC 1.00 (0.22-1.00), MPT 0.33 (0.01-0.91), NEC 1.00 (0.22-1.00), NET 0.93 (0.66-1.00), SPN 1.00 (0.22-1.00), chronic pancreatitis 0.78 (0.52-0.94), and AIP 0.73 (0.39-0.94). CONCLUSIONS : Our developed AI model can distinguish pancreatic carcinomas from noncarcinomatous pancreatic lesions, but external validation is needed.


Assuntos
Carcinoma Ductal Pancreático , Aprendizado Profundo , Neoplasias Pancreáticas , Pancreatite Crônica , Humanos , Endossonografia/métodos , Diagnóstico Diferencial , Estudos Retrospectivos , Inteligência Artificial , Neoplasias Pancreáticas/patologia , Carcinoma Ductal Pancreático/diagnóstico , Pancreatite Crônica/diagnóstico por imagem , Neoplasias Pancreáticas
15.
Dig Endosc ; 35(3): 389-393, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36170547

RESUMO

Tract dilation is one of the most difficult stages of endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), especially for beginners. To overcome this problem, we applied a special dedicated dilator. Herein, we retrospectively evaluate the safety and usefulness of a novel drill dilator in EUS-HGS. This single-center retrospective study included 20 consecutive patients who underwent EUS-HGS with a novel drill dilator. The tip is 0.77 mm, and it becomes 7F at 3 cm from tip. The track is dilated to 7F by simple clockwise rotation. The technical success rate of both initial tract dilation and stent placement was 20/20 (100%). No cases required additional dilation such as balloon or electric cautery. In 13/20 cases (65.0%), EUS-HGS was performed by beginner endoscopists. Median time required for dilation was 62.5 s (range, 30-144 s). Median procedure time was 13 min (range, 7-25 min). Early adverse events were two cases of mild fever. There was no bile leakage or bleeding. The novel drill dilator appears to be safe and useful for EUS-HGS. As it is not necessary to press the device strongly, there is no pushback during dilation and the scope position is stable. These characteristics facilitate EUS-HGS even for beginners. This device may enable the further development and increased dissemination of EUS intervention.


Assuntos
Procedimentos Cirúrgicos do Sistema Biliar , Colestase , Humanos , Estudos Retrospectivos , Drenagem/métodos , Fígado , Procedimentos Cirúrgicos do Sistema Biliar/métodos , Endossonografia/métodos , Ultrassonografia de Intervenção , Stents , Colestase/cirurgia
16.
J Infect Chemother ; 28(12): 1677-1681, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36067910

RESUMO

Plesiomonas shigelloides is a gram-negative facultative anaerobic bacillus, usually found in soil and freshwater, which causes self-limited diarrhea, although reports of bacteremia are rare. Here, we report the first case of an intratumoral abscess with mixed bacteremia caused by P. shigelloides, Citrobacter freundii, Streptococcus mitis/oralis, Clostridium perfringens, and Candida albicans in a patient with recurrent postoperative cholangiocarcinoma. A 77-year-old man with hilar cholangiocarcinoma and hypertension was admitted to our hospital with fever and abdominal pain. He had visited Vietnam for 3 years, 20 years ago. Abdominal computed tomography showed air within the recurrent tumor at the left liver lobectomy resection margin site, which was diagnosed as an intratumor abscess perforating the intestinal tract. P. shigelloides, C. freundii, S. mitis/oralis, C. perfringens, and C. albicans were isolated in blood culture. P. shigelloides was identified using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and 16S ribosomal RNA (16S rRNA) sequencing. Piperacillin-tazobactam was administered for almost a week, ampicillin-sulbactam and levofloxacin for almost 3 weeks, and antifungal agents for almost 2 weeks, and the patient was discharged thereafter. Although bloodstream infections caused by P. shigelloides in patients with cancer are extremely rare, long-term colonization and the potential for future intra-abdominal infections were implicated.


Assuntos
Bacteriemia , Neoplasias dos Ductos Biliares , Colangiocarcinoma , Plesiomonas , Sepse , Abscesso , Idoso , Antifúngicos , Bacteriemia/diagnóstico , Bacteriemia/tratamento farmacológico , Bacteriemia/microbiologia , Ductos Biliares Intra-Hepáticos , Candida albicans , Citrobacter freundii , Clostridium perfringens , Humanos , Levofloxacino , Masculino , Piperacilina , Plesiomonas/química , RNA Ribossômico 16S/genética , Solo , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Streptococcus mitis , Streptococcus oralis , Tazobactam
17.
Endosc Ultrasound ; 11(4): 319-324, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35848655

RESUMO

Background and Objectives: EUS-guided hepaticogastrostomy (EUS-HGS) is in widespread use; however, there are few dedicated devices. The B2 route is technically easier than the B3 route for guidewire insertion, dilation, and stenting but if performed with conventional oblique-viewing (OV) EUS, B2 puncture can cause transesophageal puncture and severe adverse events. The aim of this study was to assess the efficacy of forward-viewing (FV) EUS, which we have developed to improve safety for B2 puncture in EUS-HGS (B2-EUS-HGS). Patients and Methods: This single-center retrospective study included 61 consecutive patients who underwent B2-EUS-HGS with FV between February 2020 and March 2021 at Aichi Cancer Center, Japan. The patients were prospectively enrolled, and clinical data were retrospectively collected for these 61 cases. Results: The overall technical success rate of EUS-HGS was 98.3% (60/61). The rate of EUS-HGS with FV was 95.0% (58/61) after three cases converted to OV, and that of B2-EUS-HGS with FV was 88.5% (54/61). The early adverse event rate was 6.5% (4/61). There were no instances of transesophageal puncture. Median procedure time was 24 min (range, 8-70), and no patient required cautery dilation. Conclusions: B2-EUS-HGS can be performed safely using FV, without transesophageal puncture, and supportability of the device is improved as FV is coaxial with the guidewire. FV was efficacious in B2-EUS-HGS, which shows promise for clinical application in the future.

19.
Dig Endosc ; 30(3): 380-387, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29181859

RESUMO

BACKGROUND AND AIM: Cholecystitis is a major complication after self-expandable metallic stent (SEMS) placement for malignant biliary obstruction. Ischemia is one of the risk factors for cholecystitis, but little is known about the influence of tumor invasion to the feeding artery of the gallbladder on the onset of cholecystitis after SEMS placement. The aim of the present study was to identify risk factors for cholecystitis after SEMS placement. METHODS: Incidence and nine predictive factors of cholecystitis were retrospectively evaluated in 107 patients who underwent SEMS placement for unresectable distal malignant biliary obstruction at Kyoto University Hospital and Otsu Red Cross Hospital between January 2012 and June 2016. RESULTS: Cholecystitis occurred in 13 of 107 patients (12.1%) after SEMS placement during the median follow-up period of 262 days. Univariate analyses showed that tumor invasion to the feeding artery of the gallbladder and tumor involvement to the orifice of the cystic duct were significant predictors of cholecystitis (P = 0.001 and P < 0.001). Multivariate analysis confirmed that these two factors were significant and independent risks for cholecystitis with odds ratios of 22.13 (95% CI, 3.57-137.18; P = 0.001) and 25.26 (95% CI, 4.12-154.98; P < 0.001), respectively. CONCLUSIONS: This study showed for the first time that tumor invasion to the feeding artery of the gallbladder as well as tumor involvement to the orifice of the cystic duct are independent risk factors for cholecystitis after SEMS placement.


Assuntos
Colecistite/epidemiologia , Colestase/cirurgia , Vesícula Biliar/irrigação sanguínea , Neoplasias Pancreáticas/patologia , Complicações Pós-Operatórias/epidemiologia , Stents Metálicos Autoexpansíveis/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Colestase/etiologia , Feminino , Vesícula Biliar/patologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Neoplasias Pancreáticas/cirurgia , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...