1.
Food Chem ; 457: 140186, 2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38924911

RESUMO

Qu-aroma is of great significance for evaluation the quality of Daqu starter. This study aimed to decode the Qu-aroma of medium-temperature Daqu (MT-Daqu) via "top-down" and "bottom-up" approaches. Firstly, 52 aroma descriptors were defined to describe the MT-Daqu aroma by quantitative descriptive analysis. Secondly, 193 volatile organic compounds (VOCs) were identified from 42 MT-Daqu samples by HS-SPME-GC-MS, and 43 dominant VOCs were screened out by frequence of occurrence or abundance. By Thin Film (TF)-SPME-GC-O-MS, 27 odors and 90 VOCs were detected in MT-Daqu mixture, and 14 odor-active VOCs were screened out by odor intensity. Thirdly, a five-level MT-Daqu aroma wheel was constructed by matching 52 aroma descriptors and 37 aroma-active VOCs. Finally, Qu-aroma of MT-Daqu was reconstructed with 37 aroma-active VOCs and evaluated by omission experiments. Hereinto, 26 key aroma-active VOCs were determined by OAV value ≥1, including isovaleric acid, 1-hexanol, isovaleraldehyde, 2-octanone, trimethylpyrazine, γ-nonalactone, 4-vinylguaiacol, etc.

2.
J Orthop Translat ; 8: 49-61, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30035094

RESUMO

BACKGROUND/OBJECTIVE: As a widely used absorbable suture with antibacterial property, triclosan- coated polyglactin suture (Vicryl Plus) has been extensively utilized to reduce the occurrence rate of surgical site infections (SSIs) in orthopaedic surgery. However, the potential toxicity and side-effects of triclosan raised increasing concerns about its biological safety. This study aimed to investigate the antimicrobial activity and biocompatibility of quaternised chitosan-coated Vicryl suture (HV) both in vitro and in vivo. METHODS: In this study, a modified chitosan derivate, (hydroxypropyltrimethyl ammonium chloride chitosan, HACC), was coated over the surface of the absorbable Vicryl suture. Two standard bacteria strains, Staphylococcus epidermidis (ATCC35984) and methicillin-resistant Staphylococcus aureus (ATCC43300), were selected to evaluate bacterial adhesion and biofilm formation on the sutures at 6, 24 and 48 h in vitro. Additionally, human skin-derived fibroblasts cells were used to test the cytocompatibility of the sutures. Furtherly, sutures contaminated with methicillin-resistant S. aureus were implanted subcutaneously in SD rats in order to confirm the in vivo antibacterial performance and biocompatibility. RESULTS: We found that HACC-coated Vicryl suture (HV) exhibited significant anti-bacterial effects on the two tested strains. The bacterial attachment and biofilm formation on the surface of the HV sutures were found to be comparable to that of Vicryl Plus sutures (VP). Moreover, all the four tested sutures presented good cytocompatibility with human skin-derived fibroblasts cells. Histology and immunohistochemistry results indicated that the infections and inflammations were significantly inhibited around the HV and VP sutures. CONCLUSION: In general, the present study demonstrated that the quaternised chitosan coating is a flexible and cost-effective alternative strategy to prevent the suture related surgical site infections in orthopaedic practices.

3.
Int J Nanomedicine ; 11: 2223-34, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27274245

RESUMO

Titanium-based implants have been widely used in orthopedic surgery; however, failures still occur. Our in vitro study has demonstrated that gentamicin-loaded, 80 nm-diameter nanotubes possessed both antibacterial and osteogenic activities. Thus, the aim of this study was to further investigate the in vivo anti-infection effect of the titanium implants with gentamicin-loaded nanotubes. Thirty-six male Sprague Dawley rats were used to establish an implant-associated infection model. A volume of 50 µL Staphylococcus aureus suspension (1×10(5) CFU/mL) was injected into the medullary cavity of the left femur, and then the titanium rods without modification (Ti), titanium nanotubes without drug loading (NT), and gentamicin-loaded titanium nanotubes (NT-G) were inserted with phosphate-buffered saline-inoculated Ti rods as a blank control. X-ray images were obtained 1 day, 21 days, and 42 days after surgery; micro-computed tomography, microbiological, and histopathological analyses were used to evaluate the infections at the time of sacrifice. Radiographic signs of bone infection, including osteolysis, periosteal reaction, osteosclerosis, and damaged articular surfaces, were demonstrated in the infected Ti group and were slightly alleviated in the NT group but not observed in the NT-G group. Meanwhile, the radiographic and gross bone pathological scores of the NT-G group were significantly lower than those of the infected Ti group (P<0.01). Explant cultures revealed significantly less bacterial growth in the NT-G group than in the Ti and NT groups (P<0.01), and the NT group showed decreased live bacterial growth compared with the Ti group (P<0.01). Confocal laser scanning microscopy, scanning electron microscopy, and histopathological observations further confirmed decreased bacterial burden in the NT-G group compared with the Ti and NT groups. We concluded that the NT-G coatings can significantly prevent the development of implant-associated infections in a rat model; therefore, they may provide an effective drug-loading strategy to combat implant-associated infections in clinic.


Assuntos
Antibacterianos/farmacologia , Gentamicinas/farmacologia , Nanotubos/química , Próteses e Implantes , Staphylococcus aureus/efeitos dos fármacos , Titânio/química , Animais , Antibacterianos/uso terapêutico , Peso Corporal/efeitos dos fármacos , Fêmur/diagnóstico por imagem , Fêmur/efeitos dos fármacos , Fêmur/patologia , Gentamicinas/uso terapêutico , Masculino , Testes de Sensibilidade Microbiana , Nanotubos/ultraestrutura , Ratos Sprague-Dawley , Infecções Estafilocócicas/diagnóstico por imagem , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/microbiologia , Microtomografia por Raio-X
4.
J Orthop Translat ; 5: 16-25, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30035071

RESUMO

BACKGROUND/OBJECTIVE: Plasma-sprayed titanium coating (TC) with rough surfaces has been successfully applied in hip or knee prostheses. This study aimed to investigate the osteoconduction and osseointegration of Type I collagen covalently immobilised on TC (TC-AAC) compared with those of TC. METHODS: In vitro, the migration of human mesenchymal stem cells (hMSCs) on TC and TC-AAC was observed by scanning electron microscopy and visualised fluorescent live/dead assay. In vivo, a rabbit model with femur condyle defect was employed, and implants of TC and TC-AAC were embedded into the femur condyles. RESULTS: Collagen immobilised on TC could promote hMSCs' migration into the porous structure of the TC. Micro computed tomography images showed that bone trabeculae were significantly more abundant around TC-AAC implants than around TC implants. Fluorescence micrographs indicated more active new-bone formation around implants in the TC-AAC group than in the TC group. The measurement of bone-implant contact on histological sections indicated significantly greater osteointegration around TC-AAC implants than around TC ones. CONCLUSION: Immobilised Type I collagen could improve the osteoconduction and osseointegration of TC implants.