1.
Quant Imaging Med Surg ; 12(11): 5263-5270, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36330194

RESUMO

Arm positions employed during magnetic resonance imaging (MRI) can affect magnetic field distribution, which may result in variability in proton density fat fraction (PDFF) measurements. This study evaluated the effect of arm position on lumbar PDFF measured using chemical-shift-encoded MRI (CSE-MRI). Fifteen healthy volunteers from a single-center underwent lumbar CSE-MRI at two different arm positions (side and elevated) using a single 3T scanner. Scans were performed twice in each position. PDFFs of the L1-L5 vertebrae were independently measured by two readers, and reader measurements were compared by calculating intraclass correlation coefficients (ICC). We compared PDFF measurements from two arm positions and from two consecutive scans using the Wilcoxon test and Bland-Altman analysis. Measurements from the two readers were in high agreement [ICC =0.999; 95% confidence interval (CI), 0.998-0.999]. No significant difference was observed between PDFFs from the first and second scans of all vertebrae for each reader (all P>0.05); however, PDFF for the elevated arm position was significantly higher than that for the side arm position (37.9-44.8% vs. 37.0-43.8%; all P<0.05), except at the L2 level by reader 2. The mean differences in PDFF measurements from the first and second scans [0.1%; 95% limits of agreement (LoA), -1.8% to 1.9%] and from the side arm and elevated arm positions (0.8%; 95% LoA, -1.6% to 3.2%) were small. In conclusion, these preliminary data suggest that different arm positions during CSE-MRI can slightly affect lumbar PDFF; however, the mean absolute differences were very small.

2.
Radiol Phys Technol ; 15(4): 424-429, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36065048

RESUMO

Kiwifruit has been proposed as a phantom for prostate magnetic resonance imaging (MRI) to adjust multiparametric MRI factors. This study evaluated the variability in contrasts and apparent diffusion coefficients (ADCs) via repeated scans of kiwifruits for 1 week. All scans were performed using a 3T MRI system. Six kiwifruits were prepared as phantoms. Each kiwifruit was scanned consecutively for 1 week, and T2-weighted and diffusion-weighted images were acquired. Contrasts between the peripheral placenta (PP) and central placenta (CP), and between the outer pericarp (OP) and CP were calculated. The ADCs of the PP, OP, and CP were also determined. The Friedman test with Scheffé's post hoc comparison was used to assess contrast and ADC variability over 1 week; no significant differences between the contrasts or ADCs were found. Thus, each kiwifruit phantom exhibited low variability when used as a prostate MRI phantom.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Pelve , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
3.
Radiol Phys Technol ; 11(3): 338-344, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29858768

RESUMO

This phantom study assessed the effect of Gd-EOB-DTPA on T1 bias (difference in T1 between water and fat) of the proton density fat fraction when using magnetic resonance spectroscopy. Phantoms containing varying fat percentages, without and with Gd-EOB-DTPA (precontrast and postcontrast, respectively), were scanned with repetition times ranging from 1000 to 5000 ms. The relationship between the proton density fat fraction at a reference repetition time of 5000 ms and that using different repetition times, was evaluated in the precontrast and postcontrast phantoms using linear regression and Bland-Altman analyses. In the precontrast phantom, as the repetition time increased, the slope tended to approach one. In the postcontrast phantom, the slope and intercept were near one and zero, respectively. The mean difference was smaller in the postcontrast phantom (range - 0.24 to - 0.01%) than in the precontrast phantom (range 0.12 to 3.52%). We conclude that I1 bias is minimized by Gd-EOB-DTPA.


Assuntos
Gadolínio DTPA/química , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Prótons , Tecido Adiposo/química
5.
Radiol Phys Technol ; 10(4): 483-488, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28895045

RESUMO

The purpose of this study was to evaluate whether disodium gadoxetate (Gd-EOB-DTPA) affects proton density fat fractions (PDFFs) during use of the multiecho Dixon (meDixon) method in phantom and simulation magnetic resonance imaging (MRI) studies at 3 T. Fat-water phantoms comprising vegetable fat-water emulsions with varying fat volume percentages (0, 5, 10, 15, 20, 30, 40, and 50) and Gd-EOB-DTPA concentrations (0 and 0.4 mM) were prepared. Phantoms without Gd-EOB-DTPA were defined as precontrast, and those with Gd-EOB-DTPA were defined as postcontrast. All phantoms were scanned with a 3 T MRI system using the meDixon method, and precontrast and postcontrast PDFFs were calculated. Simulated pre and postcontrast PDFFs in the liver were calculated using a theoretical formula. The relationship between PDFFs measured in the pre and postcontrast phantoms was evaluated using linear regression and Bland-Altman analysis. The regression analysis comparing the pre and postcontrast PDFFs yielded a slope of 0.77 (P < 0.001). The PDFFs on the postcontrast phantom were smaller than those on the precontrast phantom. The mean difference between the PDFFs on the pre and postcontrast phantoms was 6.12% (95% confidence interval 3.13 to 9.10%; limits of agreement -0.88 to 13.11%). The simulated PDFF on the postcontrast phantom was smaller than that on the precontrast phantom. We demonstrated that the PDFF measured using the meDixon was smaller on postcontrast than on precontrast at 3 T, if a low flip angle was used. This tendency was also seen in the simulation study results.


Assuntos
Tecido Adiposo/patologia , Meios de Contraste , Gadolínio DTPA , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Prótons , Água/química , Humanos