1.
Int J Min Sci Technol ; 29(3): 343-355, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-35836709

RESUMO

Since 2009, the Mine Safety and Health Administration (MSHA) has required mines to install refuge alternatives (RAs) in underground coal mines. One of the biggest concerns with occupied RAs is the possible severity of the resulting thermal environment. In 30 CFR 7.504, the maximum allowable apparent temperature (AT) for an occupied RA is specified as 35 °C (95 °F). Manufacturers must conduct heat/humidity tests to demonstrate that their RAs meet the 35 °C (95 °F) AT limit. For these tests, heat input devices are used to input the metabolic heat of actual miners. A wide variety of test methods, sensors, and heat input devices could be used when conducting such tests. Since 2012, the National Institute for Occupational Safety and Health (NIOSH) has conducted over thirty 96-hour heat/humidity tests on four different RAs. This paper discusses the test equipment and procedures used during these investigations. This information is useful for RA manufacturers conducting RA heat/humidity tests, for other researchers investigating RA heat/humidity buildup, and for those who need to assess the thermal environment of any confined space where people may be trapped or are seeking refuge.

2.
Min Eng ; 70(8): 50-54, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30319151

RESUMO

Refuge alternatives provide shelter to miners trapped underground during a disaster. Manufacturers must demonstrate that their refuge alternatives meet the U.S. Mine Safety and Health Administration (MSHA) requirements for oxygen supply, carbon dioxide removal, and management of heat from the occupants and mechanical/chemical systems. In this study, miner size and activity level were used to determine the metabolic heat rate, oxygen requirements and carbon dioxide generation that are representative of miners in a refuge situation. A convenience sample of 198 male miners was used for the distribution of current U.S. coal miners, and the composite 95th percentile height and weight were determined to be 193 cm (76 in.) and 133 kg (293 lb). The resting metabolic rate (RMR) was determined to be representative of activity level in a refuge alternative. The highest likely metabolic heat generation ranged from 113 to 134 W, depending on occupancy. The highest required oxygen supply and carbon dioxide removal were estimated to be 23 L (0.81 cu ft) of oxygen per hour per person and 20 L (0.71 cu ft) of carbon dioxide per hour per person, which means the margin of safety is 50 percent or more compared with the MSHA requirements. The information on metabolic heat generation can be used to assess refuge alternative thermal environments by testing or simulation. The required oxygen supply and carbon dioxide removal can be used to assess refuge alternative requirements.

3.
Min Eng ; 69(4): 41-48, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28867830

RESUMO

Federal regulations require the installation of refuge alternatives (RAs) in underground coal mines. Mobile RAs have a limited ability to dissipate heat, and heat buildup can lead to a life-threatening condition as the RA internal air temperature and relative humidity increase. The U.S. National Institute for Occupational Safety and Health (NIOSH) performed heat testing on a 10-person tent-type training RA and contracted ThermoAnalytics Inc. to develop a validated thermal simulation model of the tested RA. The model was used to examine the effects of the constant mine strata temperature assumption, initial mine air temperature, initial mine strata surface temperature (MSST), initial mine strata temperature at depth (MSTD) and mine strata thermal behavior on RA internal air temperature using 117 W (400 Btu/h) of sensible heat input per simulated miner. For the studied RA, when the mine strata temperature was treated as a constant, the final predicted RA internal air temperature was 7.1°C (12.8°F) lower than it was when the mine strata thermal behavior was included in the model. A 5.6°C (10.0°F) increase in the initial MSST resulted in a 3.9°C (7.1°F) increase in the final RA internal air temperature, whereas a 5.6°C (10°F) increase in the initial MSTD yielded a 1.4°C (2.5°F) increase in the final RA internal air temperature. The results indicate that mine strata temperature increases and mine strata initial temperatures must be accounted for in the physical testing or thermal simulations of RAs.

4.
Trans Soc Min Metall Explor Inc ; 342: 29-35, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29545729

RESUMO

Research by the U.S. National Institute for Occupational Safety and Health (NIOSH) has shown that heat/humidity buildup is a major concern within coal mine refuge alternatives. High temperature and humidity levels inside a refuge alternative may expose occupants to heat stress. Due to the safety risks associated with testing using human subjects, NIOSH partnered with ThermoAnalytics Inc. to create detailed thermal simulation models of refuge alternatives with human occupants. The objective of this effort was to predict a miner's core temperature response and moisture loss in environments that may be encountered in a coal mine refuge alternative. These parameters were studied across a range of temperatures and relative humidity values to determine if the current 35 °C (95 °F) apparent temperature limit for refuge alternatives is reasonable. The results indicate that the apparent temperature limit is protective, provided that miners are supplied with sufficient water. The results also indicate that the body core temperature does not reach dangerous levels even at an apparent temperature of 54 °C (130 °F). However, the results show that moisture loss increases with apparent temperature. Therefore, if the apparent temperature limit were raised, the water provided in a refuge alternative would have to be increased to offset moisture loss.

5.
Trans Soc Min Metall Explor Inc ; 340(1): 70-74, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28736496

RESUMO

Federal regulations require that refuge alternatives (RAs) be located within 305 m (1,000 ft) of the working face and spaced at one-hour travel distances in the outby area in underground coal mines, in the event that miners cannot escape during a disaster. The Mine Safety and Health Administration mandates that RAs provide safe shelter and livable conditions for a minimum of 96 hours while maintaining the apparent temperature below 35 °C (95 °F). The U.S. National Institute for Occupational Safety and Health used a validated thermal simulation model to examine the mechanisms of heat loss from an RA to the ambient mine and the effect of mine strata composition on the final internal dry bulb temperature (DBT) for a mobile tent-type RA. The results of these studies show that 51 percent of the heat loss from the RA to the ambient mine is due to radiation and 31 percent to conduction. Three mine width and height configurations and four mine strata compositions were examined. The final DBT inside the RA after 96 hours varied by less than 1 °C (1.8 °F) for the three mine width/height configurations and by less than 2 °C (3.6 °F) for the four mine strata compositions.

6.
Min Eng ; 64(12): 64-70, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26251555

RESUMO

In collaboration with Kennametal Inc. and Corry Rubber Corporation, the U.S. National Institute for Occupational Safety and Health (NIOSH) developed a drill bit isolator to address noise overexposures associated with roof bolting machines in underground coal mines. NIOSH laboratory studies confirmed that the drill bit isolator reduces noise during drilling. Field studies were needed to confirm that a noise reduction could be obtained under working conditions and that the device was sufficiently durable. This paper reports results of field tests of the device conducted at five underground coal mines. Noise reduction was assessed by comparing the operator's noise exposure during drilling with and without the drill bit isolator. Durability was assessed by recording the number of holes and total feet drilled with each bit isolator until either the test period ended or the device failed. The results from these tests showed that the device is an effective noise control in a mine environment. The field-tested drill bit isolators provided a noise reduction of 3-5 dB(A). Of nine devices tested for durability, five exceeded 610 m (2,000 ft) drilled and two exceeded 762 m (2,500 ft) drilled before failure. Durability issues found in the field tests led to final production optimizations that have resulted in a commercially available product for drilling with 35-mm- (1.3-in.-) diameter roof bits and hexagonal drill steels.