Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Transfusion ; 51(12): 2588-95, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21682731

RESUMO

BACKGROUND: Nucleic acid testing (NAT) is currently not a routine donor test in China. The aim of this study was to evaluate the current residual risk of hepatitis B virus (HBV) transmission and the value of ALT testing in preventing HBV infection. STUDY DESIGN AND METHODS: From January 2008 to September 2009, a total of 5521 qualified donations by routine screening and 5034 deferred donations due to elevated ALT alone were collected from five blood centers. Samples were tested for HBV DNA by triplex individual-donation (ID)-NAT (ULTRIO assay, on the TIGRIS system, Novartis Diagnostics). HBV NAT-reactive samples were further analyzed by HBV serology, alternative NAT, and viral load and were diluted to simulate if they could be detected in a minipool-NAT. RESULTS: There was no significant difference in the HBV NAT-yield rate between the qualified donations group (5/5521) and the deferred donations group (4/5034). Of these nine potential HBV-yield cases, one donor (11%) was a possible HBV window-period donor, one (11%) was a chronic HBV carrier, and seven (78%) had probable or confirmed occult HBV infections. Of seven potential HBV-yield cases quantified, the viral loads were less than or equal to 70.0 IU/mL. Minipool testing (minipools of 4, 8, and 16 donations) would miss 43% to 79% of the nine HBV-yield donations. CONCLUSIONS: Based on our findings in qualified donations, we estimate that the nationwide implementation of ID-NAT testing for HBV DNA in China would detect an additional 9964 viremic donations per year. ALT testing seems to have no significant value in preventing transfusion-transmitted HBV infection. ID-NAT versus simulated minipool-NAT using the ULTRIO test demonstrates the benefit to implement a more sensitive NAT strategy in regions of high HBV endemicity.


Assuntos
Alanina Transaminase/sangue , Doadores de Sangue , DNA Viral/sangue , Seleção do Doador/métodos , Vírus da Hepatite B , Hepatite B/sangue , Hepatite B/prevenção & controle , Técnicas de Amplificação de Ácido Nucleico/métodos , Povo Asiático , China , Feminino , Hepatite B/transmissão , Humanos , Masculino , Carga Viral/instrumentação , Carga Viral/métodos
2.
Transfusion ; 47(11): 2011-6, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17958529

RESUMO

BACKGROUND: A multi-blood center study was conducted to evaluate a human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) multiplex nucleic acid testing (NAT) donor screening test and to determine the residual risk for HIV-1 and HCV infection. STUDY DESIGN AND METHODS: A commercially available HIV-1 and HCV assay (Procleix, Chiron Corp.) was used for simultaneous detection of HIV-1 RNA and HCV RNA on 89,647 unlinked donor samples. NAT was performed with pools of 16 samples that had passed all routine screening tests. Single-donor NAT was performed for samples that had been disqualified by any reactive screening test result(s). Anti-HCV (Ortho third-generation HCV enzyme immunoassay [EIA]), alanine aminotransferase, and HCV NAT (Roche COBAS Amplicor HCV test) confirmatory tests were used for HCV EIA-nonreactive, HCV NAT-reactive samples. RESULTS: Three HCV NAT yield cases and no HIV-1 yield cases were detected. The yield rate for HCV NAT was 3.4 per 10(5) (95 percent confidence interval [CI], 0.7-9.8). The estimated incidence rate for HCV is 24.2 per 100,000 person-years (95% CI, 3.4-88.0). If minipool NAT is added to routine donor screening, the residual risk for HCV is estimated to be reduced to 1 in 20.4x10(4) (95% CI, 1 in 5.2x10(4)-1 in 165.5x10(4)). CONCLUSION: The residual risk for transfusion-transmitted HCV infection is still relatively high in China. Incorporating NAT technology into blood donor screening would be estimated to reduce the residual risk of HCV infections eightfold over current EIA screening.


Assuntos
Doadores de Sangue , Infecções por HIV/diagnóstico , Hepatite C/diagnóstico , Técnicas de Amplificação de Ácido Nucleico , China , HIV/isolamento & purificação , Infecções por HIV/prevenção & controle , Infecções por HIV/transmissão , Hepacivirus/isolamento & purificação , Hepatite C/prevenção & controle , Hepatite C/transmissão , Humanos , Risco , Reação Transfusional
3.
Transfusion ; 45(11): 1816-22, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16271110

RESUMO

BACKGROUND: The correlation between signal-to-cutoff (S/CO) ratios of a second-generation hepatitis C virus (HCV) enzyme immunoassay (EIA; Abbott) and a third-generation HCV enzyme-linked immunosorbent assay (ELISA; Ortho) and confirmed HCV infection has been reported. The utility of the values for the Chinese anti-HCV EIA kits, however, has not been studied in evaluating test results in Chinese blood donors. STUDY DESIGN AND METHODS: A total of 156 donor samples repeat reactive for anti-HCV at routine screening from five representative regions of China were retested for anti-HCV by the Ortho third-generation HCV ELISA and six Chinese EIA kits and for HCV RNA by a human immunodeficiency virus-1 and HCV assay (Procleix, Chiron Corp.). The HCV RNA-nonreactive samples were further tested for anti-HCV by a third-generation recombinant immunoblot assay RIBA (Chiron Corp.). The positive result by either nucleic acid amplification test or RIBA was interpreted as confirmed HCV infection. RESULTS: The confirmed HCV prevalence rate in donors in five representative regions obtained in this study was 0.20 percent (77/37,900) in 2004. All seven anti-HCV EIA kits had a significant correlation between S/CO ratios and confirmed HCV infection. The threshold S/CO ratios, which predicted more than 95 percent of confirmed HCV infections for the Ortho, SABC, BGI-GBI, InTec, GWK, KHB, and WANTAI kits, were 3.8, 6.0, 7.0, 8.6, 10.0, 10.0, and 14.0, respectively. CONCLUSIONS: Anti-HCV EIA kits commonly used in Chinese donors screening demonstrate good correlation between S/CO ratios and the confirmed infection. For the Ortho third-generation HCV ELISA, the S/CO ratio of 3.8 determined by the US Centers for Disease Control and Prevention is applicable to Chinese blood donors. The Chinese domestic EIA kits evaluated show a diverse range of threshold S/CO ratios.


Assuntos
Doadores de Sangue , Anticorpos Anti-Hepatite C/sangue , Técnicas Imunoenzimáticas , Programas de Rastreamento , China/epidemiologia , Ensaio de Imunoadsorção Enzimática , Hepatite C/diagnóstico , Hepatite C/epidemiologia , Humanos , Valor Preditivo dos Testes , Prevalência , Kit de Reagentes para Diagnóstico , Estudos Soroepidemiológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...