Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanoscale ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38976287

RESUMO

The quest for materials with non-collinear magnetic structures has been driven by their unique properties and potential applications in advanced spintronics and data storage technologies. In this study, we investigate the induction of a non-collinear conical state in BaFe12O19 (M-type) nanocrystal fibers through the substitution of Fe3+ ions with diamagnetic Sc3+ ions. This substitution introduces an additional parameter for tuning the magnetic structure and allows precise control over the substitution amount. We demonstrate that the non-collinear conical state remains stable within a temperature range of 125 K to 325 K and can be finely adjusted by varying the Sc3+ substitution amount. The selective occupancy of Sc3+ ions at the 2a, 4f2, and 2b sites within the M-type ferrite lattice weakens the super-exchange interaction between Fe1, Fe2, and Fe5 ions. This weakening disrupts interactions between different blocks S/R (R*/S*) and stabilizes the conical state. These findings highlight a significant approach to modulating non-collinear magnetic structures in hexagonal ferrites, with implications for both fundamental research and practical applications in the development of novel magnetic materials.

2.
Sensors (Basel) ; 24(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38732839

RESUMO

Double-flank measurement is the most commonly used method for full inspection of mass-produced gears and has high measurement efficiency, but it cannot obtain the analytical parameters and is not helpful enough to evaluate the NVH performance of the gears. Based on the double-flank rolling tester with a new principle, a simulation method for double-flank measurement and a solving method for analytical parameters are proposed. Using the simulation method, the double-flank measurements without random error can be obtained through the collision detection algorithm. The solving method uses the iteration to obtain the minimum rolling length of each position of the tooth surface, then obtains the analytical parameters of the gear. In the experiments, the difference between the profile deviations obtained by the solving method and superimposed in the simulation method is less than 0.03 µm. The experiment results have verified the correctness of the simulation method and the solving method. These methods can greatly improve the value of double-flank measurement.

3.
Sensors (Basel) ; 24(10)2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38793923

RESUMO

This article proposes a new self-calibration method for circular encoders based on inertia and a single read-head. The velocity curves of the circular encoder are fitted with polynomials and, based on the principle of circle closure and the periodicity of the distribution for angle intervals, the proportionality between the theoretical value and the actual value of each angle interval is obtained. In the experimental system constructed, the feasibility of the proposed method was verified through self-calibration experiments, repeatability experiments, and comparative experiments with the time-measurement dynamic reversal (TDR) method. In addition, this article also proposes an iterative method to improve the self-calibration accuracy. Experimental verification was carried out, and the results show that the new method can effectively compensate for the error of angle measurement in the circular encoder. The peak-to-peak value of the error of angle measurement was reduced from 239.343" to 11.867", and the repeatability of the calibration results of the new method was less than 2.77".

4.
J Phys Condens Matter ; 36(34)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38759671

RESUMO

The critical behavior of the van der Waals ferromagnet Fe3.8GaTe2was systematically studied through measurements of isothermal magnetization, with the magnetic field applied along thec-axis. Fe3.8GaTe2undergoes a non-continuous paramagnetic to ferromagnetic phase transition at the Curie temperatureTc∼ 355 K. A comprehensive analysis of isotherms aroundTcutilizing the modified Arrott diagram, the Kouvel-Fisher method, the Widom scaling law, and the critical isotherm analysis yielded the critical exponent ofß= 0.411,γ= 1.246, andδ= 3.99. These critical exponents are found to be self-consistent and align well with the scaling equation at high magnetic fields, underscoring the reliability and intrinsic nature of these parameters. However, the low-field data deviates from the scaling relation, exhibiting a vertical trend whenT

5.
Sensors (Basel) ; 24(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38610500

RESUMO

The verification of the correctness, adaptability, and robustness of software systems in modern precision measurement instruments is of great significance. Due to the difficulty in processing and calibrating high-precision fine-pitch gear artefacts, the function verification and accuracy calibration of vision measurement instruments for the fine-pitch gear have become a challenge. The calibration method of the gear vision measurement system based on the virtual gear artefact involves two steps, namely obtaining and applying the virtual artefact. The obtained virtual gear artefact has the same geometric features, error features, and image edge features as the real artefact. The calibration method based on the virtual artefact can complete the correctness verification of the gear vision measurement system, and is superior to the traditional methods in adaptability verification, robustness verification, and fault analysis. In a test, the characteristic error of the virtual gear artefact could be reproduced with the original shape in the evaluation results of the computer vision gear measurement (CVGM) system, while the reproduction error did not exceed 1.9 µm. This can meet the requirements of the verification of the gear vision measurement software. The application of the virtual gear artefact can significantly improve the accuracy and robustness of the computer vision measuring instrument of the fine-pitch gear.

6.
Sensors (Basel) ; 23(24)2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38139574

RESUMO

Double-flank measurement is the most commonly used full inspection method on the shop floor. However, the double-flank measurement method cannot measure analytical parameters such as pitch deviations and profile deviations, and this limitation is a pain point in the field of gear measurement. This paper studies the measurability of the analytical parameters of gears based on the results of double-flank measurement, proposes the definition of measurable area, and gives the relationship between the size of the measurable area and the number of teeth and the pressure angle and the gear error. Digital simulation methods were used to conduct measurement experiments on gear analytical parameters. In the experiments, the measurability of the analytical parameters of gears with various typical profile deviations in the double-flank measurement process was verified and analyzed. The test results show that not all profile deviations are unmeasurable in the process of double-flank measurement, but there exists a profile region in which the analytical parameters of the gear can be measured accurately. The size of the measurable area of the profile is mainly determined by the number of teeth and pressure angle of the gear, while the pitch deviations are always measurable under normal conditions.

7.
Sensors (Basel) ; 23(22)2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-38005405

RESUMO

The clarity evaluation function plays a vital role in the autofocus technique. The accuracy and efficiency of the image clarity evaluation function directly affects the accuracy of autofocus and the speed of focusing. However, classical clarity function values are sensitive to changes in background brightness and changes in object contour length. This paper proposes a normalized absolute values adaptive (NAVA) evaluation function of image clarity. It can eliminate the influence of changes in background brightness and the length of the measured object contour on the image clarity function value. To verify the effectiveness of the NAVA function, several experiments were conducted under conditions of virtual master gear images and actual captured images. For actual captured images, the variation of the evaluation results of the NAVA function is far less than the corresponding variation of the classic clarity function. Compared with classical clarity evaluation functions, the NAVA function can provide normalized absolute clarity values. The correlations between the NAVA function results of image clarity and both the contour length and background brightness of the tested object are weak. The use of the NAVA function in automatic and manual focusing systems can further improve focusing efficiency.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...