Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 5099, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429333

RESUMO

Continuous glucose monitoring (CGM) values obtained from CGM systems using the same sensor but with different internal algorithms (the first- and third-generation FreeStyle Libre (1st-gen-libre and 3rd-gen-libre, respectively)) were compared. We used 19,819 paired and simultaneously measured CGM values of 13 patients with diabetes. The average CGM value was significantly higher (P < 0.0001) and the time below range (CGM value < 70 mg/dL) was significantly lower (P < 0.0001) with the 3rd-gen-libre than with the 1st-gen-libre. There was a significant correlation (P < 0.0001) between the CGM values of the 3rd-gen-libre (y-axis, mg/dL) and 1st-gen-libre (x-axis, mg/dL) using the following formula: y = 0.9728x + 10.024. On assessing the association between glycated hemoglobin (HbA1c (%), y-axis) and the average CGM values (x-axis, mg/dL) by applying the obtained equation to previously reported 1st-gen-libre data and converting it to 3rd-gen-libre data, we obtained the equation y = 0.02628x + 3.233, indicating that the glucose management indicator reported in the West may be underestimated compared with the laboratory-measured HbA1c in the Japanese population. Glucose values from the same sensor were found to be significantly different between readers with different algorithms, and the calculation of CGM-related indices may need to be individualized for each device.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Humanos , Glucose , Hemoglobinas Glicadas , Automonitorização da Glicemia , Monitoramento Contínuo da Glicose , Algoritmos
2.
Intern Med ; 62(7): 1023-1029, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35989272

RESUMO

We herein report a 52-year-old woman with a rare combination of short bowel syndrome due to massive resection of the small intestine and complete loss of endogenous insulin due to type 1 diabetes. To provide nutritional support, she was treated with total parenteral nutrition with co-administration of insulin, requiring careful matching of insulin and glucose levels. This case report provides insights on glycemic excursion and insulin action in type 1 diabetes, even when both insulin and glucose are administered directly into circulation, and the usual obstacles caused by subcutaneous injection of insulin and oral intake of nutrients are eliminated.


Assuntos
Diabetes Mellitus Tipo 1 , Síndrome do Intestino Curto , Feminino , Humanos , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 1/complicações , Síndrome do Intestino Curto/complicações , Insulina/uso terapêutico , Nutrição Parenteral Total , Glucose , Glicemia , Hipoglicemiantes
3.
Geriatr Gerontol Int ; 21(10): 932-938, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34390125

RESUMO

AIM: Several genetic loci related to lean mass have been identified in healthy individuals by genome-wide association studies; however, the contribution of these loci to body composition in type 2 diabetes remains to be investigated. Here, we aimed to clarify the genetic determinants of body composition in individuals with type 2 diabetes. METHODS: A total of 176 Japanese outpatients (70 women and 106 men) with type 2 diabetes were studied using a cross-sectional design. Body composition was measured using bioimpedance analysis with a commercially available device (InBody770). Single-nucleotide polymorphisms in IRS1 (rs2943656), HSD17B11 (rs9991501), VCAN (rs2287926), ADAMTSL3 (rs4842924) and FTO (rs9936385) were evaluated by genotyping. The contributions of single-nucleotide polymorphisms to body composition were examined, considering known clinical determinants. RESULTS: Sex, body composition and age were identified as clinical predictors. IRS1 rs2934656 was identified as an independent predictor of skeletal muscle mass (ß = 0.11, P = 0.026), and ADAMTSL3 rs4842924 was an independent predictor of body fat mass (ß = 0.15, P = 0.0095) and appendicular lean mass (ß = -0.13, P = 0.017). CONCLUSIONS: The findings clarified the contribution of genetic factors - IRS1 and ADAMTSL3 - to interindividual variation in body composition, independent of clinical factors, in type 2 diabetes patients. These data will contribute to the establishment of effective methods for the prediction, prevention, and intervention of sarcopenia and frailty in diabetes patients. Geriatr Gerontol Int 2021; 21: 932-938.


Assuntos
Diabetes Mellitus Tipo 2 , Sarcopenia , 17-Hidroxiesteroide Desidrogenases/genética , Proteínas ADAMTS/genética , Absorciometria de Fóton , Aldeído Oxirredutases/genética , Dioxigenase FTO Dependente de alfa-Cetoglutarato/genética , Composição Corporal/genética , Índice de Massa Corporal , Estudos Transversais , Diabetes Mellitus Tipo 2/genética , Proteínas da Matriz Extracelular , Feminino , Loci Gênicos , Estudo de Associação Genômica Ampla , Humanos , Proteínas Substratos do Receptor de Insulina/genética , Masculino , Músculo Esquelético , Sarcopenia/genética , Versicanas/genética
4.
Sci Rep ; 11(1): 4006, 2021 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-33597626

RESUMO

The targets for continuous glucose monitoring (CGM)-derived metrics were recently set; however, studies on CGM data over a long period with stable glycemic control are limited. We analyzed 194,279 CGM values obtained from 19 adult Japanese patients with type 1 diabetes. CGM data obtained during stable glycemic control over four months were analyzed. CGM-related metrics of different durations "within 120, 90, 60, 30, and 7 days" were calculated from baseline. Time in range (TIR; glucose 70-180 mg/dL), time above range (TAR; glucose ≥ 181 mg/dL), and average glucose levels, but not time below range (TBR; glucose ≤ 69 mg/dL), strongly correlated with glycated hemoglobin (HbA1c) values (P < 0.0001). TBR correlated with glucose coefficient of variation (CV) (P < 0.01). Fasting serum C-peptide levels negatively correlated with glucose CV (P < 0.01). HbA1c of approximately 7% corresponded to TIR of 74% and TAR of 20%. The shorter the CGM period, the weaker was the relationship between HbA1c and CGM-related metrics. TIR, TAR, and average glucose levels accurately reflected HbA1c values in Japanese patients with type 1 diabetes with stable glycemic control. Glucose CV and TBR complemented the limitation of HbA1c to detect glucose variability and hypoglycemia. Stable glycemic control with minimal hypoglycemia depended on residual ß-cell function.


Assuntos
Automonitorização da Glicemia/métodos , Glicemia/análise , Hemoglobinas Glicadas/análise , Adulto , Idoso , Glicemia/química , Diabetes Mellitus Tipo 1/epidemiologia , Diabetes Mellitus Tipo 1/metabolismo , Feminino , Glucose/metabolismo , Hemoglobinas Glicadas/metabolismo , Humanos , Hipoglicemia/metabolismo , Hipoglicemia/fisiopatologia , Hipoglicemiantes , Insulina/metabolismo , Células Secretoras de Insulina/metabolismo , Células Secretoras de Insulina/fisiologia , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade
5.
J Diabetes Investig ; 12(5): 728-737, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32986906

RESUMO

AIMS/INTRODUCTION: Glucosuria is a representative symptom in diabetes patients with poor glycemic control and in those treated with sodium-glucose cotransporter 2 inhibitors. Renal threshold levels of glucose excretion are known to vary among individuals, but factors contributing to glucosuria are not well characterized. The present study aimed to clarify clinical and genetic determinants of glucosuria in individuals with diabetes mellitus. MATERIALS AND METHODS: The 24-h urinary glucose excretion was measured in 135 hospitalized patients on admission, with continuous measurement for five consecutive days in 75 patients. Genetic and clinical factors contributing to glucosuria were studied. As a genetic factor, SLC5A2 polymorphism was genotyped. A total of 476 participants (266 participants with type 2 diabetes and 210 healthy controls) were additionally genotyped for the association study of SLC5A2 with type 2 diabetes. A meta-analysis was carried out with the present study and previous association studies. RESULTS: Multiple regression analysis showed that the independent variables of average blood glucose (ß = 0.41, P = 1.4 × 10-7 ), estimated glomerular filtration rate (ß = 0.28, P = 6.0 × 10-5 ), sex (ß = 0.28, P = 5.7 × 10-5 ) and SLC5A2 rs9934336 polymorphism (ß = 0.17, P = 0.02) were significantly correlated with urinary glucose excretion. The frequency of the A allele of rs9934336 tended to be lower in participants with type 2 diabetes than in controls (odds ratio 0.78, 95% confidence interval 0.53-1.13, not significant), and meta-analysis showed a significant association between the A allele and type 2 diabetes (summary odds ratio for minor allele [A] 0.86, 95% confidence interval 0.78-0.94, P < 0.002). CONCLUSIONS: Blood glucose, estimated glomerular filtration rate, sex and SLC5A2 polymorphism were independent determinants of glucosuria in diabetes mellitus.


Assuntos
Diabetes Mellitus Tipo 2/genética , Diabetes Mellitus Tipo 2/urina , Glucose/análise , Glicosúria/genética , Transportador 2 de Glucose-Sódio/genética , Idoso , Glicemia/análise , Estudos de Casos e Controles , Feminino , Frequência do Gene , Genótipo , Taxa de Filtração Glomerular , Glicosúria/sangue , Glicosúria/urina , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Polimorfismo Genético , Análise de Regressão , Fatores Sexuais
6.
J Diabetes Investig ; 11(5): 1222-1229, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32027468

RESUMO

AIMS/INTRODUCTION: A flash glucose monitoring (FGM) system has become available. To clarify the relationship between FGM and self-monitoring blood glucose (SMBG) values, we compared the two values after simultaneous measurement in Japanese patients with type 1 diabetes, under daily life settings. MATERIALS AND METHODS: A total of 20 outpatients with type 1 diabetes were analyzed. When FGM and SMBG were carried out simultaneously (within ±3 min), the values were adopted and each FGM value was matched and compared with the corresponding SMBG value. In addition, we analyzed other cases of simultaneity defined as "within ±2 min," "within ±1 min" and "at the exact same time." RESULTS: The percentage of SMBG and FGM values in the clinically acceptable zone A + B in Clarke and consensus error grid analyses were 97.9 and 99.2%, respectively. Deming regression (x-axis: FGM values, y-axis: SMBG values) determined a slope of 0.9128 (95% confidence interval 0.9008-0.9247) and an intercept of +15.94 mg/dL (95% confidence interval 14.05-17.84). FGM values were lower than SMBG values in the lower glucose range, and higher in the higher glucose range. The shorter the time lag between measurements, the higher the rate of concordance between FGM and SMBG values. CONCLUSIONS: The results of this study provided evidence on the reliability of FGM in Japanese patients with type 1 diabetes in home conditions. Based on the results, if an abnormal glucose value is detected by FGM, SBMG should then be used to confirm the result.


Assuntos
Biomarcadores/análise , Automonitorização da Glicemia/métodos , Glicemia/análise , Diabetes Mellitus Tipo 1/diagnóstico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Monitorização Ambulatorial/métodos , Adulto , Idoso , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/metabolismo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Prognóstico , Reprodutibilidade dos Testes
7.
J Diabetes Investig ; 9(5): 1084-1090, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29288524

RESUMO

AIMS/INTRODUCTION: Patients with a total pancreatectomy and type 1 diabetes are similar in regard to absolute insulin deficiency, but different in regard to glucagon, providing a unique opportunity to study the contribution of glucagon to glucose metabolism in an insulin-dependent state. The aim of the present study was to investigate the contribution of glucagon to glucose homeostasis in complete insulin deficiency in vivo. METHODS: A total of 38 individuals with a complete lack of endogenous insulin (fasting C-peptide <0.0066 nmol/L) and whose glycemic control was optimized with an insulin pump during hospitalization were retrospectively studied. The basal insulin requirement, time-to-time adjustment of the basal insulin infusion rate, prandial insulin requirement and fasting plasma glucagon were compared between patients with a total pancreatectomy (n = 10) and those with type 1 diabetes (n = 28) after achievement of optimal glycemic control. RESULTS: Total daily insulin (P = 0.03) and basal insulin (P = 0.000006), but not prandial insulin requirements, were significantly lower in total pancreatectomy patients than in type 1 diabetes patients. The basal percentage (basal insulin/total daily insulin) was also significantly lower in total pancreatectomy patients than in type 1 diabetes patients (15.8 ± 7.8 vs 32.9 ± 10.1%, P = 0.00003). An increase in the insulin infusion rate early in the morning was not necessary in most patients with a pancreatectomy. The fasting plasma glucagon concentration was significantly lower in total pancreatectomy patients than in type 1 diabetes patients (P = 0.00007), and was positively correlated with the basal insulin requirement (P = 0.038). CONCLUSIONS: The difference in insulin requirements between total pancreatectomy and type 1 diabetes patients suggests a contribution of glucagon to the basal insulin requirement and dawn phenomenon.


Assuntos
Diabetes Mellitus Tipo 1/cirurgia , Glucagon/administração & dosagem , Insulina/metabolismo , Pancreatectomia , Idoso , Estudos de Casos e Controles , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 1/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
8.
J Diabetes Investig ; 2017 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-28963752

RESUMO

AIMS/INTRODUCTION: Differences in the efficacy and safety of antidiabetic drugs among different ethnic groups are well documented. Metformin is widely used in the treatment of type 2 diabetes in Western countries, but high doses of metformin have been approved only recently for clinical use in Japan. The aim of the present study was to investigate the effects of dosage and dosing frequency on the efficacy and safety of high-dose metformin in Japanese patients. MATERIALS AND METHODS: A total of 71 Japanese patients with type 2 diabetes were prospectively studied for the effects of dosage and dosing frequency on the efficacy and safety of metformin during hospitalization. Dose effects were studied in 27 patients treated with 0, 500, 1,000, 1,500 and 2,250 mg/day of metformin. The effect of dosing frequency was compared in 56 patients with 1,500 mg/day of metformin administered either two or three times per day. RESULTS: Significant dose-dependent improvement in daily profiles of blood glucose was observed with metformin dosages up to 1,500 mg/day, with a trend towards further improvement observed at 2,250 mg/day. The efficacy of 1,500 mg of metformin was comparable when the drug was administered either two or three times per day. The most frequently reported side-effects were gastrointestinal symptoms, which were not affected by the dosage or dosing frequency of metformin. CONCLUSIONS: These results show that the efficacy of high-dose metformin is dose-dependent in Japanese patients. The efficacy and safety of metformin were similar when the drug was administered either two or three times per day.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...