Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Support Care Cancer ; 32(5): 295, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38635051

RESUMO

OBJECTIVE: The aim of this in vitro study was to evaluate the effect of radiotherapy on the surface microhardness and roughness of different bioactive restorative materials. MATERIALS AND METHODS: A total of 60-disc specimens (5 mm × 2 mm) were performed in four groups (n = 15 each) from Equia Forte HT, Cention N, Activa Bioactive Restorative, and Beautifil II. Following the polishing procedure (600, 1000, 1200 grit silicon carbide papers), all specimens were irradiated at 2 Gy per fraction, five times a week for a total dose of 70 Gy in 30 fractions over 7 weeks. Before and after the irradiation, the specimens were analyzed regarding the surface roughness and microhardness. Surface morphology was also analyzed by scanning electron microscopy. Kruskal-Wallis test, Wilcoxon test, and paired sample t-test were used for statistical analysis. RESULTS: Significant differences were found after radiation with increased mean roughness of both Cention N (p = 0.001) and Beautifil II (p < 0.001) groups. In terms of microhardness, only the Beautifil II group showed significant differences with decreased values after radiation. There were statistically significant differences among the groups' roughness and microhardness data before and after radiotherapy (p < 0.05). CONCLUSION: The effect of radiotherapy might differ according to the type of the restorative material. Although results may differ for other tested materials, giomer tends to exhibit worse behaviour in terms of both surface roughness and microhardness. CLINICAL RELEVANCE: In patients undergoing head and neck radiotherapy, it should be taken into consideration that the treatment process may also have negative effects on the surface properties of anti-caries restorative materials.


Assuntos
Cárie Dentária , Radioterapia (Especialidade) , Humanos , Cariostáticos , Pescoço , Projetos de Pesquisa
2.
Lasers Med Sci ; 37(8): 3237-3247, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35829976

RESUMO

This study aims to evaluate the effect of diode laser- or LED-activated tooth bleaching on color change, tooth sensitivity(TS), temperature variation, and gingival irritation (GI) for 9 months. Thirty-five subjects having anterior teeth with a color of A2 or darker were enrolled in the study. In a split-mouth design, one side of each arch was activated by a diode laser (Epic X, Biolase), and the other side was activated by an LED (Radii Plus, SDI) in conjunction with a bleaching agent (35%, Whiteness HP). The color change was evaluated by subjective (VitaClassic/Vita3D Master Bleachguide) and objective (spectrophotometer, Vita Easyshade) methods for up to 9 months. TS and GI were assessed by visual analogue scale (VAS) and gingival index, respectively, at the same recall periods. During the bleaching, the temperature variation was also recorded using a thermocouple. Statistical analyses were performed (p < 0.05). In the color evaluation, no statistically significant difference was found between diode laser and LED (p > 0.05), except for the 6-month spectrophotometric assessment (ΔE00, ΔEab), where higher values were obtained with the laser (p < 0.05). The temperature difference and maximum temperature with diode were found to be significantly higher than LED (p < 0.05). Higher values were obtained with LED when the mean temperatures were compared (p < 0.05). There was no difference between the two activation methods in terms of TS and GI at any of the recalls (p > 0.05). The bleaching activated either with diode laser or LED performed similar clinical performance in terms of effective color change, tooth sensitivity, and gingival irritation with minimum temperature variations.


Assuntos
Clareadores , Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Seguimentos , Humanos , Peróxido de Hidrogênio , Lasers Semicondutores/uso terapêutico , Clareamento Dental/métodos , Resultado do Tratamento
3.
J Clin Pediatr Dent ; 44(4): 240-248, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33167017

RESUMO

PURPOSE: To evaluate the effect of different enamel conditioning protocols and their re-application on the microleakage of fissure sealants placed following saliva contamination. STUDY DESIGN: The study included 156 human third molars in 16 subgroups (2×4×2) under two main groups (sealant type): Group A- hydrophobic resin sealant, 3M Clinpro™ Sealant; Group B- hydrophilic resin sealant, Ultraseal XT Hydro. Each group was then divided according to the type of surface conditioning; 1- Er,Cr:YSSG laser etching, 2- acid-etching, 3- acid-etching+etch-and-rinse adhesive (Prime&Bond® One Select) and 4- self-etching adhesive (Clearfil™ SE Bond). After contaminating the conditioned occlusal enamel surfaces with artificial saliva, fissure sealant was applied in half of the specimens (a), whereas in the other half, (b) the respective surface conditioning was repeated and then fissure sealant was placed. Following thermocycling, the samples were immersed in basic fuchsin, sectioned, and dye penetration was quantitatively assessed with ImageJ. Two-way ANOVA and Bonferroni post-hoc tests were used for statistical analyses (p<0.05). RESULTS: The least microleakage was observed in A3b and A3a, whereas B4b and B4a were the subgroups with the highest microleakage. Following saliva contamination, when surface conditioning was not re-applied, the effects of fissure sealant types and surface conditioning were significant (p=0.005 and p<0.001, respectively). However, their interaction was insignificant (p=0.173). When surface conditioning was re-applied after saliva contamination, the effects of type of fissure sealant and surface conditioning (p=0.000, for both) and their interaction (p=0.004) were significant. CONCLUSIONS: 3M Clinpro™ Sealant was superior to Ultraseal XT Hydro. Re-application of Er,Cr:YSSG laser and the self-etching adhesive did not affect the microleakage of both fissure sealants. Without re-application, acid-etching+etch-and-rinse adhesive was superior to acid-etching only. However, both of them were similarly successful when they were re-applied following saliva contamination.


Assuntos
Colagem Dentária , Infiltração Dentária , Condicionamento Ácido do Dente , Esmalte Dentário , Infiltração Dentária/prevenção & controle , Humanos , Teste de Materiais , Selantes de Fossas e Fissuras , Saliva
4.
Lasers Med Sci ; 30(2): 695-700, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23912781

RESUMO

The aim of this in vitro study was to evaluate the shear bond strength (SBS) of Silorane System Adhesive to enamel and dentin surfaces that had been etched with different procedures. Ninety freshly extracted human third molars were used for the study. After the teeth were embedded with buccal surfaces facing up, they were randomly divided into two groups. In group I, specimens were polished with a 600-grit silicon carbide (SiC) paper to obtain flat exposed enamel. In group II, the overlying enamel layer was removed and exposed dentin surfaces were polished with a 600-grit SiC paper. Then, the teeth in each group were randomly divided into three subgroups according to etching procedures: etched with erbium, chromium:yttrium-scandium-gallium-garnet laser (a), etched with 35% phosphoric acid (b), and non-etched (c, control). Silorane System Adhesive was used to bond silorane restorative to both enamel and dentin. After 24-h storage in distilled water at room temperature, a SBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. The data were analyzed using two-way ANOVA and Bonferroni tests (p < 0.05). The highest SBS was found after additional phosphoric acid treatment in dentin groups (p < 0.05). There were no statistically significant differences between the laser-etched and non-etched groups in enamel and dentin (p > 0.05). The SBS of self-etch adhesive to dentin was not statistically different from enamel (p > 0.05). Phosphoric acid treatment seems the most promising surface treatment for increasing the enamel and dentin bond strength of Silorane System Adhesive.


Assuntos
Condicionamento Ácido do Dente/métodos , Esmalte Dentário/química , Adesivos Dentinários/química , Lasers , Dente Molar/cirurgia , Resinas de Silorano/química , Cloraminas/química , Colagem Dentária/métodos , Análise do Estresse Dentário , Humanos , Lasers de Estado Sólido , Teste de Materiais , Ácidos Fosfóricos , Resistência ao Cisalhamento , Compostos de Tosil/química
5.
Dent Res J (Isfahan) ; 11(5): 537-43, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25426142

RESUMO

BACKGROUND: The purpose of this study was to determine the effect of three chewing gums and paraffin on the remineralization and the hardness of demineralized enamel. MATERIALS AND METHODS: A total of 12 subjects wore intraoral palatal appliances with two demineralized bovine enamel slabs. The study consisted of four experimental periods each lasting 21-days, during which subjects were assigned to one of three gum-chewing regimens: gum containing sorbitol, xylitol and a mixture of sorbitol and xylitol and with paraffin as control. The appliances were worn during gum-chewing for 20 min and then retained for 20 min 4 times/day. The slabs were subjected to energy dispersive X-ray spectroscopy analysis and surface microhardness measurements before in setting into the appliance and after the experimental period. The data were subjected to analysis of variance for repeated measures. A P < 0.05 was considered statistically significant. RESULTS: Mineral analysis revealed no significant difference between the baseline and after chewing periods for all groups (P > 0.05). No significant difference was found among the groups either for the baseline measurements or after chewing periods (P > 0.05). All groups showed higher microhardness values after the chewing periods than the baseline except for the Vivident Xylit group (P < 0.05). CONCLUSION: The chewing of gum had no effect on the Ca/P ratio of demineralized enamel surfaces. The hardening of the demineralized enamel surfaces may vary according to the type of chewing gum.

6.
Lasers Med Sci ; 28(1): 343-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22821150

RESUMO

The aim of this in vitro study was to evaluate the effect of laser treatment on shear bond strength of a self-adhesive flowable resin composite to human dentin. Eighty extracted sound human molar teeth were used for the study. The teeth were sectioned mesiodistally and embedded in acrylic blocks. The dentin surfaces were ground wet with 600-grit silicon carbide (SiC) paper. They were randomly divided into two preparation groups: laser (Er:YAG laser, with 12 Hz, 350 mJ energy) and control (SiC). Each group was then divided into two subgroups according to the flowable resin composite type (n = 20). A self-adhesive flowable (Vertise Flow) and a conventional flowable resin (Premise Flow) were used. Flowable resin composites were applied according to the manufacturer's recommendations using the Ultradent shear bond Teflon mold system. The bonded specimens were stored in water at 37 °C for 24 h. Shear bond strength was tested at 1 mm/min. The data were logarithmically transformed and analyzed using two-way analysis of variance and Student-Newman-Keul's test at a significance level of 0.05. The self-adhesive flowable resin showed significantly higher bond strength values to laser-prepared surfaces than to SiC-prepared surfaces (p < 0.001). The conventional flowable resin did not show such differences (p = 0.224). While there was a significant difference between the two flowable resin composites in SiC-prepared surfaces (p < 0.001), no significant difference was detected in laser-prepared surfaces (p = 0.053). The bond strength of a self-adhesive flowable resin composite differs according to the type of dentin surface preparation. Laser treatment increased the dentin bonding values of the self-adhesive flowable resin.


Assuntos
Resinas Compostas/química , Adesivos Dentinários/química , Lasers de Estado Sólido , Cimentos de Resina/química , Análise de Variância , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Dente Molar , Distribuição Aleatória , Propriedades de Superfície
7.
Eur J Dent ; 7(Suppl 1): S060-S065, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24966730

RESUMO

OBJECTIVE: The objective of this study was to evaluate the effect of operator variability on microleakage with different adhesive systems. MATERIALS AND METHODS: A total of 180 standardized Class V cavities were prepared on facial and lingual of 90 extracted human premolar teeth and randomly assigned to five groups according to the adhesive systems used (n = 36): Prime and Bond NT (PB), Single Bond (SB), Futura Bond NR, Xeno III (XE) and Adper Prompt-L-Pop (LP). The adhesive groups were then further subdivided into three operator groups according to level of clinical experience (n = 12): An undergraduate student, a research assistant and a faculty member. All cavities were restored with same composite resin. The restored teeth were thermocycled (500 cycles, 5-55°C) then immersed in 0.5% basic fuchsin and measured for leakage under a stereomicroscope. Statistical analyses were performed with the Kruskal-Wallis and Mann-Whitney U tests. RESULTS: Significant inter-operator variation was found in the enamel margins in the XE group with significantly higher microleakage when used by the undergraduate student (P < 0.05). Although no significant differences in microleakage were found between adhesive systems for the research assistant and faculty member (P > 0.05), significant differences were observed between PB and LP, PB and XE, SB and LP and SB and XE in the enamel margins for the undergraduate student (P < 0.05). CONCLUSION: Microleakage of adhesive systems is more dependent on interactions between the operator and adhesive material than on the choice of adhesive material.

8.
Eur J Dent ; 6(4): 389-95, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23077418

RESUMO

OBJECTIVE: To determine the relationship between margin preparation design and resin-composite type on microleakage with or without re-application of surface-penetrating sealant. METHODS: Class-I resin-composite restorations were completed for 128 extracted human molars. Half of the margins were beveled, the other half, butt-joint. Half of each group was restored with Filtek-Supreme (FS), the other half with Esthet-X (EX) using their respective adhesive systems. Margins were etched and sealed with a surface-penetrating sealant, Fortify. The samples were stored in water 24h, and thermocycled (5,000 cycles, 5°C-55°C). Then, samples were abraded using a toothbrush machine (6,000 strokes). Half of the restorations from each sealant group (n=16) were resealed, and the other half had no further treatment. Thermocycling and tooth brushing were repeated. The samples were sealed with nail polish, immersed in methylene-blue for 8h, sectioned, and magnified digital photographs were taken. Three examiners assessed dye penetration. A 2×2×2 multi-layered Chi-Square analysis, using Cochran-Mantel-Haenszel test was conducted for statistical analysis. RESULTS: No difference was observed between sealed and resealed FS and EX restorations with butt-joint margins. In beveled margins, resealing caused significantly less microleakage (P<.01). No differences were found between restorations either sealed or resealed with bevel margins. In butt-joint margins, at the leakage level deeper than 2/3 of the preparation depth, resealed FS showed less microleakage than EX resealed restorations (P<.01). CONCLUSION: Resealing reduced microleakage in bevel margins, however, in butt-joint margins resealing did not affect the leakage. A significant statistical relationship exists between and within resealing, margin preparation design, type of composite, and microleakage.

9.
Eur J Dent ; 6(3): 280-6, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22904656

RESUMO

OBJECTIVE: The aim of this study was to compare the shear bond strength of several self-etch adhesives to their two-step predecessors to ground and unground enamel. METHODS: Seventy-five extracted, non-carious human third molar teeth were selected for this study. The buccal surfaces of each tooth were mechanically ground to obtain flat enamel surfaces (ground enamel), while the lingual surfaces were left intact (unground enamel). The teeth were randomly divided into five groups according to the adhesive systems (n=15): one-step self-etch adhesive - Clearfil S3 Bond, its two-step predecessor - Clearfil SE Bond, one-step self-etch adhesive - AdheSE One, and its two-step predecessor - AdheSE, and a two-step etch-and-rinse adhesive - Adper Single Bond 2(control). After application of the adhesives to the buccal and lingual enamel surfaces of each tooth, a cylindrical capsule filled with a hybrid composite resin (TPH) was seated against the surfaces. The specimens were stored in distilled water at 37°C for 24 hours, followed by thermocy-cling (5°C-55°C/500 cycles). They were subjected to shear bond strength test in a universal testing machine at a crosshead speed of 1.0 mm/minute. The data were compared using a two-way ANOVA, followed by Bonferroni test at P<.05. RESULTS: All adhesives exhibited statistically similar bond strengths to ground and unground enamel except for the etch-and-rinse adhesive that showed significantly higher bond strengths than the self-etch adhesives (P<.05). No significant differences in bond strength values were observed between ground and unground enamel for any of the adhesives tested (P=.17). CONCLUSION: Similar bond strengths to ground and unground enamel were achieved with one-step self-etch adhesives and their predecessors. Enamel preparation did not influence the bonding performance of the adhesives tested.

10.
J Adhes Dent ; 14(5): 485-92, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22724113

RESUMO

PURPOSE: To evaluate the 24-month clinical performance of cervical restorations using a nanohybrid and a flowable resin composite with a one-step self-etching adhesive. MATERIALS AND METHODS: Twenty-one patients with at least one pair of non-carious cervical lesions participated in this study. A total of 134 non-carious cervical lesions were restored (67 with a nanohybrid resin composite, Grandio; 67 with a flowable resin composite, Grandio Flow) using a one-step self-etching adhesive system, Futura Bond NR, by one dentist. The restorations were evaluated for retention, color match, marginal discoloration, marginal adaptation, surface texture, anatomic form, and secondary caries by two calibrated examiners at baseline and after 6, 12, and 24 months using modified USPHS criteria. The survival rates of the restorations were calculated by the Kaplan-Meier estimator. The comparison of resin composites for each category was performed with the Pearson chi-square test, and the performance of restorations at baseline and after each recall time was evaluated using McNemar's test (p < 0.05). RESULTS: All patients attended the 24-month recall. The retention rates at 6 months were 66% and 58%, and 61% and 57% at 12 months for Grandio and Grandio Flow, respectively. At the 24-month recall, the retention rate was 60% for Grandio and 54% for Grandio Flow. No statistically significant differences were found in retention rates among the restorative materials in any evaluation period (p > 0.05). For marginal discoloration and anatomical form, three Grandio and three Grandio Flow restorations showed Bravo scores at the end of 24 months. The restorations in both groups had Alfa ratings of 100% for the rest of the criteria evaluated. CONCLUSION: The nanohybrid and flowable resin composites showed similar clinical performances in the restoration of non-carious cervical lesions over 24 months.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Restauração Dentária Permanente/métodos , Nanocompostos/química , Colo do Dente/patologia , Desgaste dos Dentes/terapia , Idoso , Bis-Fenol A-Glicidil Metacrilato/química , Cor , Colagem Dentária , Adaptação Marginal Dentária , Retenção em Prótese Dentária , Feminino , Seguimentos , Humanos , Masculino , Metacrilatos/química , Pessoa de Meia-Idade , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Propriedades de Superfície , Análise de Sobrevida
11.
J Am Dent Assoc ; 143(2): 115-22, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22298552

RESUMO

BACKGROUND: Glass ionomer sealants are an alternative to resin-based sealants, especially for use in partially erupted permanent molars. The authors conducted a study to compare the retention, marginal staining and cariostatic properties of a glass ionomer sealant with those of a resin-based sealant during a 24-month period. METHODS: We included in this study 39 patients aged 5 through 9 years who had bilateral partially erupted first permanent molars. One of us (S.B.) placed a resin-based sealant (Delton Plus FS+, Dentsply Professional, York, Pa.) (group D) on a partially erupted first molar in one quadrant of the maxilla or mandible and a glass ionomer sealant (GC Fuji Triage White, GC America, Alsip, Ill.) (group T) in the other quadrant. Two masked and calibrated investigators (S.A.A., J.C.) evaluated the sealants for retention, marginal staining and carious lesions at three, six, 12 and 24 months. The authors used a multinomial regression for statistical analysis (P < .05). RESULTS: The recall rate was 69.2 percent at 24 months. Two sealants from group D and three from group T were lost completely. Complete retention rates at 24 months were 40.7 and 44.4 percent for groups D and T, respectively. The authors found no statistically significant difference in retention rates between groups at each recall examination (P > .05). For marginal staining, sealants in the resin-based group exhibited statistically higher marginal staining than did sealants in the glass ionomer group (P < .05). Although the authors detected no caries in teeth in group T, teeth in group D in which the sealant was lost completely experienced demineralization. CONCLUSIONS: Resin-based and glass ionomer sealants exhibited similar retention rates at 24 months. However, marginal staining was lower in the glass ionomer group, and the authors found no caries in teeth in this group. Consequently, glass ionomer sealants may be a better choice when salivary contamination is expected. CLINICAL IMPLICATIONS: Sealing during tooth eruption presents a particular challenge owing to difficulty in isolating the tooth. Glass ionomers may be a better material for sealing partially erupted molars.


Assuntos
Cimentos de Ionômeros de Vidro/uso terapêutico , Dente Molar/anatomia & histologia , Selantes de Fossas e Fissuras/uso terapêutico , Cimentos de Resina/uso terapêutico , Condicionamento Ácido do Dente/métodos , Resinas Acrílicas/química , Cariostáticos/uso terapêutico , Criança , Pré-Escolar , Cor , Colagem Dentária , Materiais Dentários/química , Seguimentos , Humanos , Ácidos Polimetacrílicos/química , Propriedades de Superfície , Desmineralização do Dente/classificação , Erupção Dentária
12.
Lasers Med Sci ; 27(1): 23-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20842517

RESUMO

The aim of this study was to compare the effects of the Er,Cr:YSGG laser using chemical vapour deposition (CVD) bur cavity preparation with conventional preparation methods including a diamond bur and a carbide bur on the microleakage with two different adhesive systems. A total of 40 extracted human premolars were randomly assigned to four experimental groups according to the cavity preparation technique: group I diamond bur (Diatech); group II carbide bur (Diatech); group III Er,Cr:YSGG laser (Biolase Millennium II); and group IV CVD bur (CVDentUS). Using the different preparation techniques, Class V standardized preparations were performed on the buccal and lingual surfaces with gingival margins on the dentin and occlusal margins on the enamel. Each preparation group was randomly assigned to two subgroups (five teeth, ten preparations) according to the type of adhesive: an etch-and-rinse adhesive (Adper Single Bond), and a single-step self-etch adhesive (AdheSE One). All preparations were restored with a nanohybrid composite resin in a single increment. Following thermocycling (×500; 5-55°C), the teeth were immersed in basic fuchsin and sectioned in the orovestibular direction. Dye penetration was evaluated under a light microscope by two blinded examiners. Data were statistically analysed with the Kruskal-Wallis and Wilcoxon tests (p<0.05). There were no statistically significant differences between the preparation techniques with either of the two adhesive systems (p>0.05). Comparing the enamel and dentin leakage scores within each group, no statistically significant differences were found (p>0.05). The Er,Cr:YSGG laser cavity preparation did not differ from preparation with CVD, diamond or carbide bur in terms of microleakage with the different adhesive systems.


Assuntos
Preparo da Cavidade Dentária/métodos , Infiltração Dentária , Lasers de Estado Sólido , Dente Pré-Molar/efeitos da radiação , Resinas Compostas/química , Cárie Dentária , Esmalte Dentário/efeitos da radiação , Dentina/efeitos da radiação , Diamante , Humanos
13.
Lasers Med Sci ; 27(4): 805-11, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21853319

RESUMO

The aim of this study was to compare the effect of the Er,Cr:YSGG laser and different cavity disinfection agents on microleakage of an etch-and-rinse and a self-etch adhesive. Class V preparations were completed on the buccal and lingual surfaces of 30 extracted noncarious human molars. The occlusal margin was placed on enamel and the gingival margin on dentin. Preparations were randomly divided into five experimental groups (n = 12); (1) 2% chlorhexidine gluconate (CHX), (2) propolis, (3) ozone, (4) Er,Cr:YSGG laser, and (5) control (no treatment). Each group was divided into two subgroups according to the adhesive system: etch-and-rinse (Adper Single Bond 2), and a self-etch adhesive (All-Bond SE). The preparations were bulk-filled with a resin composite (Arabesk). After storage in distilled water for 24 h the restored teeth were subjected to thermocycling (1,000 cycles; 5-55°C). All specimens were immersed in 0.5% basic fuchsin solution for 24 h and sectioned longitudinally through the centre of the restorations and examined under a stereomicroscope at ×25 magnification. The data were analysed using the Kruskal-Wallis and Mann-Whitney U-tests. No difference was observed between the groups either on enamel or dentin when the etch-and-rinse adhesive was used (p > 0.05). In the self-etch adhesive groups, a significant difference was found only between the laser group and the CHX group on enamel and between the propolis group and the control group on dentin (p < 0.05). Comparing the etch-and-rinse and self-etch adhesives within each group, no differences were found on dentin (p > 0.05). On enamel, a statistically significant difference was found only in the CHX group (p < 0.05). There were no differences in microleakage with the laser and the different cavity disinfectant applications when used with etch-and-rinse adhesive. In the self-etch group there were differences in microleakage depending on the disinfection agent used.


Assuntos
Resinas Compostas/química , Cimentos Dentários/efeitos da radiação , Infiltração Dentária/radioterapia , Adesivos Dentinários/química , Desinfecção/métodos , Lasers de Estado Sólido , Corrosão Dentária , Dentina/microbiologia , Dentina/efeitos da radiação , Humanos , Dente Molar
14.
J Contemp Dent Pract ; 12(4): 279-86, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22186863

RESUMO

AIM: This in vitro study evaluated the effect of different cavity disinfection agents on bond strength of a silorane-based resin composite. MATERIALS AND METHODS: Thirty-six caries-free human third mandibular molars sectioned in mesio-distal direction were mounted in acrylic resin with their flat dentin surfaces exposed. After the dentin surfaces were wet ground with # 600 silicon carbide paper, the teeth were randomly divided into 6 groups of 12 each according to the cavity disinfection agents; chlorhexidine (CHX); sodium hypochlorite (NaOCl), propolis, ozone, Er,Cr:YSGG laser and no treatment (control). After treatment of dentin surfaces with one of these cavity disinfection agents, Filtek Silorane adhesive system was applied. The silorane-based resin composite, Filtek Silorane was condensed into a mold and polymerized. After storage at 37°C for 24 hours, the specimens were tested in shear mode at a crosshead speed of 1.0 mm/minute. The results were analyzed by one-way ANOVA. RESULTS: No statistically significant difference was observed between the groups (p>0.05). CONCLUSION: The use of the tested cavity disinfection agents, chlorhexidine, sodium hypochlorite, propolis, ozone and Er,Cr:YSGG laser did not significantly affect the dentin bond strength of a silorane-based resin composite, filtek supreme. CLINICAL SIGNIFICANCE: Cavity disinfectant applications did not affect the dentin bond strength of a silorane-based resin composite.


Assuntos
Anti-Infecciosos Locais , Resinas Compostas , Colagem Dentária , Preparo da Cavidade Dentária , Restauração Dentária Permanente , Adesivos Dentinários , Siloxanas , Análise de Variância , Clorexidina , Desinfetantes de Equipamento Odontológico , Análise do Estresse Dentário , Humanos , Lasers de Estado Sólido , Teste de Materiais , Ozônio , Própole , Cimentos de Resina , Resistência ao Cisalhamento , Resinas de Silorano , Hipoclorito de Sódio
15.
J Dent ; 39 Suppl 1: e9-17, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21256180

RESUMO

OBJECTIVES: The aim of this study was to compare four finishing/polishing systems (F/P) on surface roughness and gloss of different resin composites. METHODS: A total of 40 disc samples (15 mm × 3 mm) were prepared from a nanofill - Filtek Supreme Plus (FS) and a micro-hybrid resin composite - Esthet-X (EX). Following 24h storage in 37°C water, the top surfaces of each sample were roughened using 120-grit sandpaper. Baseline measurements of surface roughness (Ra, µm) and gloss were recorded. Each composite group was divided into four F/P disk groups: Astropol[AP], Enhance/PoGo[EP], Sof-Lex[SL], and an experimental disk system, EXL-695[EXL] (n=5). The same operator finished/polished all samples. One sample from each group was evaluated under SEM. Another blinded-operator conducted postoperative measurements. Results were analysed by two-way ANOVA, two interactive MANOVA and Tukey's t-test (p<0.05). RESULTS: In surface roughness, the baseline of two composites differed significantly from each other whereas postoperatively there was no significance. The Sof-Lex F/P system provided the smoothest surface although there were no statistical significance differences between F/P systems (p>0.01). In gloss, FS composite with the EXL-695 system provided a significantly higher gloss (p<0.01). EX treated by Soflex revealed the least gloss (p<0.05). SEM images revealed comparable results for F/P systems but EX surfaces included more air pockets. CONCLUSIONS: Four different finishing/polishing systems provided comparable surface smoothness for both composites, whereas EXL with FS provided significantly higher gloss. SEM evaluations revealed that the EX surface contained more air pockets but F/P systems were compatible.


Assuntos
Resinas Compostas , Polimento Dentário/métodos , Teste de Materiais , Microscopia Eletrônica de Varredura , Análise Multivariada , Nanocompostos , Propriedades de Superfície
16.
Oper Dent ; 35(5): 500-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20945740

RESUMO

This study evaluated the two-year clinical performance of two minimally invasive cavity preparation techniques, bur and laser, in Class I occlusal resin composite restorations. Twenty-seven patients, each having at least one pair of occlusal caries, were enrolled in this study. For each patient, one of the cavities was prepared with a diamond bur, and the other was prepared with Er, Cr:YSGG laser. The cavities were restored with a nanofilled flowable resin composite, Grandio Flow, using an etch-and-rinse adhesive, Solobond M. A total of 108 restorations were placed in molars by a single operator. The restorations were evaluated according to modified Cvar/Ryge criteria. The evaluations were performed at baseline, 6, 12, 18 and 24 months after initial placement by two calibrated operators. The Chi-square and Fisher's exact test were used for statistical analysis. All the patients were available during all evaluated periods, resulting in a recall rate of 100%. The retention rates of the restorations at 24 months were 98.1% for bur and 100% for the laser-prepared group. After 24 months, 5.6% of the bur-prepared and 7.4% of the laser-prepared restorations were rated Bravo in marginal discoloration (p > 0.05). Bur-prepared (9.3%) and laser-prepared (13%) restorations were rated Bravo in marginal adaptation (p > 0.05). There were no significant differences between the two cavity preparation techniques regarding the evaluated parameters (p > 0.05). Both cavity preparation techniques performed equally, with excellent outcomes after a 24-month period.


Assuntos
Resinas Compostas , Preparo da Cavidade Dentária/instrumentação , Materiais Dentários , Restauração Dentária Permanente/métodos , Lasers de Estado Sólido/uso terapêutico , Cor , Resinas Compostas/química , Colagem Dentária , Cárie Dentária/diagnóstico , Cárie Dentária/terapia , Preparo da Cavidade Dentária/métodos , Adaptação Marginal Dentária , Materiais Dentários/química , Retenção em Prótese Dentária , Adesivos Dentinários/química , Feminino , Seguimentos , Humanos , Terapia a Laser/instrumentação , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Dente Molar/patologia , Nanocompostos/química , Propriedades de Superfície , Resultado do Tratamento , Adulto Jovem
17.
J Esthet Restor Dent ; 22(3): 186-92, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20590972

RESUMO

BACKGROUND: Tooth bleaching has become a routine treatment due to patients' esthetic demands. PURPOSE: The aim of this study was to evaluate how prerestorative home-bleaching affected microleakage of resin composite restorations bonded with etch-and-rinse and self-etch adhesives. MATERIALS AND METHODS: Fifty extracted human premolar teeth were used. The bleaching agent (10% carbamide peroxide) was applied to the buccal surface of each tooth for 6 hours a day for 2 weeks. The lingual surfaces of the same teeth received no application (control). The teeth were stored in artificial saliva. After 14 days, standardized Class V cavity preparations (2 mm high, 3 mm wide, and 2 mm deep) were made on the buccal and lingual surfaces with all margins in the enamel. They were randomly divided into five groups according to the adhesive systems: an etch-and-rinse adhesive (Single Bond [SB]), two two-step self-etch adhesives (Adper SE Plus [ASE] and One Coat [OC]), and two one-step self-etch adhesives (Adper Easy One [EO] and G-Bond [GB]). All adhesives were applied according to the manufacturers' instructions. The preparations were then restored using the same hybrid composite (Filtek Z250) in one increment and light-cured. The teeth were thermocycled (5/55 degrees C, 1,000x) and immersed in dye, then sectioned, and dye penetration was scored. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U-tests. RESULTS: Although statistically significant differences were found between the adhesive systems in the bleached teeth, no differences were observed in the control groups (non-bleached teeth). There were significant differences between SB/GB, SB/EO, SB/OC, and GB/ASE in the bleached teeth (p < 0.05). When comparing bleached and non-bleached teeth within each adhesive system, only SB and EO produced higher leakage scores when bleaching was applied. The other groups showed no difference in terms of bleaching (p > 0.05). CONCLUSION: Prerestorative home-bleaching had an adverse effect on microleakage of SB and EO. CLINICAL SIGNIFICANCE: The effect of prerestorative home-bleaching agents on microleakage of composite resin restorations differs according to the type of adhesive material used.


Assuntos
Bis-Fenol A-Glicidil Metacrilato/efeitos adversos , Infiltração Dentária/etiologia , Oxidantes/efeitos adversos , Peróxidos/efeitos adversos , Cimentos de Resina/efeitos adversos , Clareamento Dental/efeitos adversos , Ureia/análogos & derivados , Dente Pré-Molar , Peróxido de Carbamida , Resinas Compostas/efeitos da radiação , Esmalte Dentário/efeitos dos fármacos , Corrosão Dentária/métodos , Restauração Dentária Permanente , Humanos , Cura Luminosa de Adesivos Dentários , Ureia/efeitos adversos
18.
J Adhes Dent ; 12(3): 231-6, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20157672

RESUMO

PURPOSE: To compare the effects of quartz-tungsten-halogen (QTH) and light-emitting-diode (LED) curing units on the 3-year clinical performance of a nanofilled composite resin in noncarious cervical lesions. MATERIALS AND METHODS: Twenty-six patients with at least 2 noncarious cervical lesions were enrolled in the study. A total of 154 restorations were placed: half polymerized with QTH and half polymerized with LED. Single Bond was used as the adhesive and Filtek Supreme was used as the restorative material for all restorations. The restorations were assessed by two different examiners using modified Ryge/USPHS criteria at baseline and at 6, 12, 24, and 36 months. The survival rates were analyzed with the Kaplan-Meier estimator and the Log-Rank test, and the statistical analysis was completed using Pearson's chi-square test (p < 0.05). RESULTS: Twenty patients were available for recall after 3 years and 114 restorations were evaluated (recall rate of 74%). The survival rate was 84% for QTH and LED polymerized restorations. There were no statistically significant differences in survival rates between the light-curing units (p > 0.05). No significant differences were observed between QTH and LED polymerized restorations in terms of any of the evaluation criteria at the end of 3 years (p > 0.05). No color change in the restorations was observed and none of them exhibited secondary caries at the end of 3 years. CONCLUSION: Over the 3-year study period, both curing units, QTH and LED, produced acceptable clinical results in noncarious cervical lesions.


Assuntos
Resinas Compostas/química , Lâmpadas de Polimerização Dentária/classificação , Materiais Dentários/química , Restauração Dentária Permanente , Nanocompostos/química , Colo do Dente/patologia , Doenças Dentárias/terapia , Idoso , Bis-Fenol A-Glicidil Metacrilato/química , Cor , Cárie Dentária/etiologia , Adaptação Marginal Dentária , Adesivos Dentinários/química , Feminino , Seguimentos , Humanos , Cura Luminosa de Adesivos Dentários , Masculino , Pessoa de Meia-Idade , Propriedades de Superfície , Análise de Sobrevida
19.
Eur J Dent ; 4(1): 50-6, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20046480

RESUMO

OBJECTIVES: The aim of this study was to investigate the effect of delayed finishing/polishing on the surface roughness, hardness and gloss of tooth-coloured restorative materials. METHODS: Four different tooth-coloured restoratives: a flowable resin composite- Tetric Flow, a hybrid resin composite- Venus, a nanohybrid resin composite- Grandio, and a polyacid modified resin composite- Dyract Extra were used. 30 specimens were made for each material and randomly assigned into three groups. The first group was finished/polished immediately and the second group was finished/polished after 24 hours. The remaining 10 specimens served as control. The surface roughness of each sample was recorded using a laser profilometer. Gloss measurements were performed using a small-area glossmeter. Vickers microhardness measurements were performed from three locations on each specimen surface under 100g load and 10s dwell time. Data for surface roughness and hardness were analyzed by Kruskal Wallis test and data for gloss were subjected to one-way ANOVA and Tukey test (P <.05). RESULTS: The smoothest surfaces were obtained under Mylar strip for all materials. While there were no significant differences in surface roughness of immediate and delayed finished/polished Dyract Extra samples, immediately finished/polished Venus and Grandio samples showed significantly higher roughness than the delayed polished samples (P <.05). In Tetric Flow samples, immediately finishing/polishing provided smoother surface than delayed finishing/polishing (P <.05). The highest gloss values were recorded under Mylar strip for all materials. While delayed finishing/polishing resulted in a significantly higher gloss compared to immediate finishing/polishing in Venus samples (P <.05), no differences were observed between delayed or immediate finishing/polishing for the other materials (P>.05). The lowest hardness values were found under Mylar strip. Delayed finishing/polishing significantly increased the hardness of all materials. CONCLUSIONS: The effect of delayed finishing/polishing on surface roughness, gloss and hardness appears to be material dependent.

20.
Oper Dent ; 34(6): 642-7, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19953772

RESUMO

OBJECTIVE: This clinical study compared the retention rates of a nanofilled occlusal fissure sealant placed with the use of an etch-and-rinse or a self-etch adhesive over 24 months. METHODS: Two-hundred and forty-four sealants were placed on the permanent premolars and molars of 16 subjects who had no restorations or sealants present on the fissures and no detectable caries. The sealants were placed with either SoloBond M two-step etch-and-rinse adhesive or FuturaBond NR one-step self-etch adhesive by four previously calibrated dentists, using a table of random numbers. After completion of the adhesive application, a nanofilled sealant, Grandio Seal, was applied and light-cured. Clinical evaluations were done at baseline and at 1-, 3-, 6-, 12-, 18- and 24-month recalls. Two other calibrated examiners, who were unaware of which adhesive had been used, independently evaluated the sealants. Evaluation of the sealants on every follow-up visit involved visual examination with the aid of a dental explorer and an intra-oral mirror. Each sealant was evaluated with the following criteria: 1 = completely retained; 2 = partial loss; 3 = total loss. The Pearson Chi-square test was used to evaluate differences in the retention rates among the sealants used with different adhesives for each evaluation period. RESULTS: For the 12-month recalls, complete retention rates of 89.3% for the SoloBond M group and 20.5% for the FuturaBond NR group were observed. Sixteen of the 244 restorations were unavailable after 12 months. At 24 months, a total loss of 9 sealants in the SoloBond M group and 84 in the FuturaBond NR group were observed, resulting in retention rates of 81.6% and 15.8%, respectively. There were statistically significant differences in retention rates between the SoloBond M and FuturaBond NR groups in all periods of evaluation (p < 0.05). No statistically significant difference between the retention rates for premolars and molars was found at each evaluation period (p > 0.05). There was no new caries formation throughout the 24-month recall period. CONCLUSION: Fissure sealants placed with etch-and-rinse adhesive showed better retention rates than those placed with self-etch adhesive.


Assuntos
Fissuras Dentárias/terapia , Adesivos Dentinários , Selantes de Fossas e Fissuras , Humanos , Metacrilatos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...